{"product_id":"abb-s201-b6-2cds251001r0065-s200-miniature-circuit-breaker","title":"ABB S201-B6 2CDS251001R0065 S200 Miniature Circuit Breaker","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eS201-B6\u003c\/strong\u003e miniature circuit breaker with Product ID \u003cstrong\u003e2CDS251001R0065\u003c\/strong\u003e is a single-pole, current-limiting safety device engineered to provide comprehensive overcurrent mitigation and short-circuit fault protection. As a core component of the \u003cstrong\u003eSystem pro M compact\u003c\/strong\u003e \u003cstrong\u003eS200\u003c\/strong\u003e product range, this device features two distinct internal tripping mechanisms: a delayed thermal tripping configuration optimized for overload security and an electromechanical magnetic tripping assembly designed for instantaneous short-circuit protection. This circuit breaker is rated for a 6 A operational current and complies fully with major international standards including IEC\/EN 60898-1, IEC\/EN 60947-2, and UL1077, enabling seamless system compatibility across diverse residential, commercial, and heavy industrial automation environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIncorporates a 1P single-pole configuration designed for space-saving terminal tracking and efficient distribution layout.\u003c\/li\u003e\n\u003cli\u003eUtilizes a B-characteristic tripping curve calibrated for specific line and low-surge inductive application parameters.\u003c\/li\u003e\n\u003cli\u003eFeatures an integrated contact position indicator with a clear visual window displaying Red for ON and Green for OFF states.\u003c\/li\u003e\n\u003cli\u003eOutfitted with a failsafe bidirectional cylinder-lift screw terminal setup to optimize wiring stability and prevent installation errors.\u003c\/li\u003e\n\u003cli\u003eEngineered for high modular versatility with full compatibility for bottom-fitting auxiliary contact installations and accessories.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow-voltage electrical distribution boards and branch circuit panel assemblies.\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels, manufacturing automation loops, and specialized machinery control networks.\u003c\/li\u003e\n\u003cli\u003eCommercial building facility management grids and standard residential infrastructure protection loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Product Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS201-B6 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS251001R0065 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779464901 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Product Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS201-B6 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS251001R0065 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Protected Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTripping Characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\/DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRated Operational Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eacc. to IEC 60898-1 230 V AC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eacc. to IEC\/EN 60664-1 440 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV (5 kV at 2000 m \/ 6.2 kV at Sea Level) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Test Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz - 1 min: 2 kV \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-Circuit Capacity (Icn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(AC) 6 kA \/ (DC) 6 kA \/ (230\/400 V AC) 6 kA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Ultimate Short-Circuit Breaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(133 V AC) 20 kA \/ (230 V AC) 10 kA \/ (24 V DC) 20 kA \/ (60 V DC) 10 kA \/ (230 V) 10 kA \/ (400 V) 10 kA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Service Short-Circuit Breaking Capacity (Ics)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(133 V AC) 15 kA \/ (230 V AC) 7.5 kA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Conditional Short-Circuit Current (Inc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(230 V) 10 kA \/ (400 V) 10 kA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Frequency (f)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 W (2 W per Pole at Rated Operating Conditions) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation Group II, RAL 7035 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation Group II, Black, Sealable \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToggle \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Position Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed ON \/ Green OFF \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnergy Limiting Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Endurance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20000 AC cycle \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Endurance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20000 cycle \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScrew Terminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFailsafe Bidirectional Cylinder-lift Terminal \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnecting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbar 10\/10 mm² \/ Flexible with Ferrule 0.75 ... 25 mm² \/ Flexible 0.75 ... 25 mm² \/ Rigid 0.75 ... 35 mm² \/ Stranded 0.75 ... 35 mm² \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8 N-m \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Screw Driver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePozidriv 2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Stripping Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Air Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation -25 ... +55 Celsius \/ Storage -40 ... +70 Celsius \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (Enclosure with Cover IP40) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Voltage UL\/CSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 V DC \/ 480Y\/277 V AC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Rating acc. to UL1077\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(277 V AC) 6 kA \/ (60 V DC) 10 kA \/ (120 V) 10 kA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnecting Capacity UL\/CSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbar 18-8 AWG \/ Conductor 18-4 AWG \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening Torque UL\/CSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 in-lb \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.112 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Installation:\u003c\/strong\u003e Secure the unit firmly onto standard symmetrical tracking choices, including TH35-15 (35 x 15 mm mounting rail) or TH35-7.5 (35 x 7.5 mm mounting rail) according to the IEC 60715 standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Position:\u003c\/strong\u003e The underlying physical design permits installation and execution at any functional mechanical angle orientation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Connection:\u003c\/strong\u003e The architecture allows for arbitrary power supply connection placements based on structural needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Anchoring:\u003c\/strong\u003e Securely clamp the conductors inside the failsafe bi-directional cylinder-lift terminals with a Pozidriv 2 screwdriver to a certified torque of 2.8 N-m (18 in-lb for UL\/CSA configurations).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeclaration of Conformity - CE:\u003c\/strong\u003e 2CDK403001D0607 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeclaration of Conformity - UKCA:\u003c\/strong\u003e 9AKK108467A5053 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification Agencies:\u003c\/strong\u003e EN, IEC, UL \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC\/EN 60898-1, IEC\/EN 60947-2, UL 1077\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53456094364011,"sku":"S201-B6 2CDS251001R0065","price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/S201-B62CDS251001R0065_2.jpg?v=1783127720","url":"https:\/\/www.plcprotech.com\/de\/products\/abb-s201-b6-2cds251001r0065-s200-miniature-circuit-breaker","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}