{"product_id":"abb-s282uc-k10-ghs2820164r0427-miniature-circuit-breakers-mcbs","title":"ABB S282UC-K10 GHS2820164R0427 S280UC Miniature Circuit Breaker","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB S282UC-K10\u003c\/strong\u003e miniature circuit breaker with Product ID \u003cstrong\u003eGHS2820164R0427\u003c\/strong\u003e is a 2-pole universal current protection device engineered to provide reliable current limitation and electrical fault security. As part of the \u003cstrong\u003eS280UC\u003c\/strong\u003e product family, this device features a high direct current voltage rating, making it an excellent option for demanding DC configurations alongside standard AC systems. The unit incorporates two distinct internal tripping mechanisms: a delayed thermal tripping system calibrated for overload protection and an electromechanical magnetic assembly designed for immediate short-circuit interruption. Compliant with international standards including IEC\/EN 60947-2, UL1077, and CSA 22.2 No. 235, this circuit breaker ensures safe and stable performance across specialized infrastructure systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutfitted with a 2-pole configuration designed for concurrent multi-line isolation and control.\u003c\/li\u003e\n\u003cli\u003eUtilizes a K-characteristic tripping curve calibrated for specific motor and inductive load management.\u003c\/li\u003e\n\u003cli\u003eFeatures a high inbuilt direct current operational rating optimized for specialized high-voltage setups.\u003c\/li\u003e\n\u003cli\u003eIncorporates an integrated contact position indicator with clear mechanical ON\/OFF visual feedback.\u003c\/li\u003e\n\u003cli\u003eEquipped with rugged cable clamp screw terminals to ensure stable and secure conductor anchoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePhotovoltaics and renewable energy collection grids.\u003c\/li\u003e\n\u003cli\u003eTelecommunication power distribution installations.\u003c\/li\u003e\n\u003cli\u003eElectric traction and transport infrastructure networks.\u003c\/li\u003e\n\u003cli\u003eIndustrial automation loops and commercial low-voltage distribution panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Product Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS282UC-K10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGHS2820164R0427\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4012233637201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTripping Characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eacc. to IEC60898-1 440 V DC \/ 440 V AC \/ 484 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eacc. to IEC\/EN 60664-1 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum (incl. tolerance) 440 V AC \/ 484 V DC, Minimum 12 V AC \/ 12 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Frequency (f)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Short-Circuit Capacity (Icn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.0 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Ultimate Short-Circuit Breaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Service Short-Circuit Breaking Capacity (Ics)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV (6.2 kV at Sea Level, 5.0 kV at 2000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Test Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz, 1 min: 2 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation group I, RAL 7035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation group II, black, sealable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Position Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eON\/OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Endurance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 AC cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Endurance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20000 cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScrew Terminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnecting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbar 16 mm² \/ Flexible with Ferrule 0.75 ... 16 mm² \/ Flexible 0.75 ... 16 mm² \/ Rigid 0.75 ... 25 mm² \/ Stranded 0.75 ... 25 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 N-m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Screw Driver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePozidriv 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Air Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation -25 ... +55 Celsius \/ Storage -40 ... +70 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 cycles with 55 Celsius at 90-96% and 25 Celsius at 95-100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance to Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eacc. to IEC 60068-2-27: 30g \/ 3 shocks \/ 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance to Vibrations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eacc. to IEC 60068-2-6: 5g, 20 cycles at 5 ... 150 ... 5 Hz with load 0.8 In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (IP40 inside enclosure with cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Voltage UL\/CSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V DC \/ 480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnecting Capacity UL\/CSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConductor 18 ... 4 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening Torque UL\/CSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain Circuit 17.5 in lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Rating acc. to UL1077\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.260 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Installation:\u003c\/strong\u003e Mount the unit securely on standard symmetrical profiles including TH35-7.5 (35 x 7.5 mm mounting rail) or TH35-15 (35 x 15 mm mounting rail) complying with IEC 60715 guidelines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Position:\u003c\/strong\u003e The mechanical enclosure is engineered to allow terminal mounting in any valid orientation angle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePolarity Awareness:\u003c\/strong\u003e Due to the specific design requirements for universal current loops, please observe the direct current polarity indicators closely during layout connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Securing:\u003c\/strong\u003e Tighten electrical lines into the integrated cable clamp connections using a Pozidriv 2 screwdriver to a certified torque value of 2.5 N-m (17.5 in lb for UL\/CSA arrangements).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeclaration of Conformity - CE:\u003c\/strong\u003e 2CDK400002D0401\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Information:\u003c\/strong\u003e 2CDK400005K0201 \/ Following EU Directive 2002\/95\/EC August 18, 2005 and amendment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e IEC\/EN 60947-2, UL 1077, CSA 22.2 No. 235\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53456099377515,"sku":"S282UC-K10 GHS2820164R0427","price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/S282UC-K10GHS2820164R0427.jpg?v=1783128195","url":"https:\/\/www.plcprotech.com\/de\/products\/abb-s282uc-k10-ghs2820164r0427-miniature-circuit-breakers-mcbs","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}