{"product_id":"abb-sf810i-los-uvir-t-uvisor-sf810i-multi-fuel-integrated-safe-flame-scanner","title":"ABB SF810I-LOS-UVIR-T Uvisor SF810i Multi Fuel Integrated Safe Flame Scanner","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB SF810I-LOS-UVIR-T (SF810INT-LOS-UVIR-T-C-W )\u003c\/strong\u003e is an advanced multi-fuel integrated safe flame scanner belonging to the \u003cstrong\u003eUvisor SF810i\u003c\/strong\u003e and \u003cstrong\u003eSymphony Plus\u003c\/strong\u003e product families. This module acts as an integrated, self-contained intelligent combustion sensor, combining the optical detection assembly and the signal analysis processor within a single rugged enclosure. Engineered for challenging multi-fuel burners, it features dual-sensor detection capability utilizing both Ultraviolet (UV) and Infrared (IR) solid-state sensors to continuously monitor the presence or absence of individual burner flames. Beyond absolute flame discrimination, the device continuously analyzes flame modulation characteristics to compute real-time qualitative combustion stability trends. It features a Line-of-Sight (LOS) optical orientation, an internal termination board with plug-in terminal blocks, and an embedded Modbus RTU RS485 communication link for peripheral integration. Powered by a nominal 24 VDC input, the scanner operates without a separate remote evaluation unit, delivering safety-critical flame relay contacts and analog quality tracking outputs directly from the burner-mounted unit.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated all-in-one architecture housing both optical sensors and microprocessing electronics inside the burner head unit.\u003c\/li\u003e\n\u003cli\u003eDual solid-state UV and IR sensor arrangement designed for multi-fuel discrimination and coal, oil, or gas combustion profiling.\u003c\/li\u003e\n\u003cli\u003eLine-of-Sight (LOS) optical orientation configuration for direct direct-view flame alignment.\u003c\/li\u003e\n\u003cli\u003eNative electronic communication via built-in Modbus RTU over a 2-wire RS485 physical layer.\u003c\/li\u003e\n\u003cli\u003eDirect on-board user configuration management accessible via raw Modbus registers or PC-based software utilities.\u003c\/li\u003e\n\u003cli\u003eInternal terminal block module layout fitted with an integrated termination board for straightforward field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-fuel utility burners using independent or simultaneous gas, oil, and pulverized coal firing.\u003c\/li\u003e\n\u003cli\u003eContinuous flame supervision and discrimination within industrial steam boilers and power generation furnaces.\u003c\/li\u003e\n\u003cli\u003eReal-time qualitative monitoring of flame combustion dynamics and burner performance.\u003c\/li\u003e\n\u003cli\u003eBurner Management System (BMS) integration via direct hardwired flame safety relays.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue \/ Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSF810I-LOS-UVIR-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSF810INT-LOS-UVIR-T-C-W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInvoice Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSF810INT-LOS-UVIR-T-C-W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Code Structure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated (SF810i), Line of Sight (LOS), UV + IR Sensors (UVIR), Terminal Block Termination (T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue \/ Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUvisor SF810i Series (Integrated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSymphony Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensing Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid-state Ultraviolet (UV) + Infrared (IR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine-of-Sight (LOS) \/ Direct View\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTermination Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-in terminal blocks via internal termination board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-485, 2-wire half-duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChina (CN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9031809090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.087 in (180 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.31 in (135 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.236 in (260 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.372 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction \/ Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Termination Board\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProvides plug-in screw terminal blocks for field conductor routing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlame Relay Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndependent hardwired output for direct safety-critical integration with the BMS.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Output Channel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent loop configuration representing real-time flame signal quality metrics.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRS485 Serial Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-wire connection supporting remote parameter alignment and diagnostic data fetch over Modbus RTU.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUnscrew the housing access cover to expose the integrated internal termination board for conductor assignment.\u003c\/li\u003e\n\u003cli\u003eWire the power supply and communication paths to the plug-in terminal blocks, using shielded twisted-pair cables for the 2-wire RS485 Modbus network to minimize transient noise.\u003c\/li\u003e\n\u003cli\u003eMount the device onto the burner sight pipe via its designated Line-of-Sight mechanical flange link, aligning the assembly directly with the target primary combustion zone.\u003c\/li\u003e\n\u003cli\u003eApply low-pressure purging air to the cooling jacket assembly if operating in high thermal environments to protect the solid-state sensor window from soot buildup and overheating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53443545694571,"sku":"SF810I-LOS-UVIR-T","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/SF810I-LOS-UVIR-T.jpg?v=1782870643","url":"https:\/\/www.plcprotech.com\/de\/products\/abb-sf810i-los-uvir-t-uvisor-sf810i-multi-fuel-integrated-safe-flame-scanner","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}