{"product_id":"allen-bradley-1769-of4-compactlogix-compact-i-o-analog-output-module","title":"Allen-Bradley 1769-OF4 CompactLogix Compact I\/O Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1769-OF4\u003c\/strong\u003e is a 4-channel single-ended analog output module belonging to the \u003cstrong\u003eCompactLogix Compact I\/O\u003c\/strong\u003e system family. This hardware component translates digital processing variables into precision analog current or voltage signals, permitting direct coordination with field devices such as valve actuators, speed drives, and analog instrumentation panel paths. Operating over normal signaling ranges including 0 to 20 mA, 4 to 20 mA, 0 to 5V DC, 1 to 5V DC, 0 to 10V DC, and plus or minus 10V DC, the module integrates an over-range and under-range clamping architecture that automatically bounds active outputs to specified clamp settings upon value limit violation. Equipped with a system bus communication interface, the controller commands real-time multi-channel data adjustments over an internal backplane loop, complete with a physical diagnostics indicator for real-time fault identification.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIncorporates 4 high-accuracy single-ended voltage or current output channels.\u003c\/li\u003e\n\u003cli\u003eProvides high digital resolution matching 15 bits plus sign across unipolar and bipolar operational bounds.\u003c\/li\u003e\n\u003cli\u003eFeatures a built-in over-range and under-range detection system that locks field outputs to precise safety boundaries.\u003c\/li\u003e\n\u003cli\u003eOutfitted with a front-facing Module OK LED indicator mapping power verification and software validation checks.\u003c\/li\u003e\n\u003cli\u003eConfigured with non-volatile operational calibrations removing downstream hardware adjustment criteria.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVariable speed drive control loops and multi-axis motor velocity configuration.\u003c\/li\u003e\n\u003cli\u003eProportional industrial control valve modulation inside fluid or pneumatic distribution plants.\u003c\/li\u003e\n\u003cli\u003eRemote process manipulation and setpoint tracking paths linked to distributed controller platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1769-OF4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 single-ended (voltage or current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Operating Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...20 mA, 4...20 mA, ±10V DC, 0...10V DC, 0...5V DC, 1...5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Scale Analog Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...21 mA, 3.2...21 mA, ±10.5V DC, -0.5...10.5V DC, -0.5...5.25V DC, 0.5...5.25V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 bits plus sign unipolar and bipolar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConversion Rate (All Channels)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 2.5 ms (Interrupts not enabled), Max 3.8 ms (Interrupts enabled)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStep Response to 63%\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.9 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistive Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent: 0...600 Ohm (includes wire resistance); Voltage: 1 kOhm or greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInductive Load, Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mH (current loads), 1.0 uF (voltage loads)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5% full scale at 25 Celsius (77 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Current Draw, Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 mA @ 5V DC; 170 mA @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.86 Total Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Power Supply Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 8 modules away from system power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBelden 8761 (shielded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESD Immunity (IEC1000-4-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV contact, 8 kV air, 4 kV indirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadiated Immunity (IEC1000-4-3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10V\/m, 80...1000 MHz, 80% amplitude modulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst (IEC1000-4-4)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kV, 5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Immunity (IEC1000-4-5)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kV galvanic gun\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConducted Immunity (IEC1000-4-6)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10V, 0.15...80 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...60 Celsius (32...140 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...85 Celsius (-40...185 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m (6561 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Vibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10...500 Hz, 5 g, 0.030 in. peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 g, 11 ms panel mounted (20 g, 11 ms DIN rail mounted)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNonoperating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 g panel mounted (30 g DIN rail mounted)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (HxWxD), Approx\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e118 x 35 x 87 mm (4.65 x 1.38 x 3.43 in.); Height with tabs: 138 mm (5.43 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight, Approx\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 g (0.61 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the module is positioned no further than 8 expansion spaces away from the primary system power supply unit.\u003c\/li\u003e\n\u003cli\u003eSecure the housing firmly onto a standard industrial DIN rail structure, or bolt directly onto an internal cabinet panel layout utilizing the built-in retractable mounting tabs.\u003c\/li\u003e\n\u003cli\u003eHook up the field signaling paths using Belden 8761 or an equivalent shielded twisted-pair cable format to optimize signal protection.\u003c\/li\u003e\n\u003cli\u003eKeep terminal loop lengths and wire distributions isolated from heavy alternating current motor distribution tracks to mitigate EMI induction risks.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695177625963,"sku":"1769-OF4","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1769-of4-compact-i-o-modules-ykdwpmmkwp3_26a82a36-f575-4967-b90c-f0a63c4d2bb0.jpg?v=1766114171","url":"https:\/\/www.plcprotech.com\/de\/products\/allen-bradley-1769-of4-compactlogix-compact-i-o-analog-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}