{"product_id":"beckhoff-el6752-ethercat-terminal-devicenet-master-module","title":"BECKHOFF EL6752 EtherCAT Terminal DeviceNet-Master-Modul  ","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eIntegration of legacy DeviceNet fieldbus topologies into high-speed EtherCAT networks is achieved directly through the \u003cstrong\u003eEL6752\u003c\/strong\u003e communication module. This 1-channel terminal operates as a fully functional DeviceNet master (scanner), allowing the connection of up to 63 decentralized DeviceNet slaves to a centralized EtherCAT control loop. The module acts as an efficient bridge, handling local fieldbus diagnostics and signal mapping with high deterministic accuracy.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF EL6752\u003c\/strong\u003e features physical and galvanic isolation to protect internal E-bus circuitry from external electrical transients. Its compact 24 mm housing integrates status LEDs for rapid visual diagnostics of bus communication status, network errors, and power supply. This interface is optimal for retrofitting existing manufacturing lines, integrating legacy sensors, and managing distributed I\/O systems in heavy industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSingle-channel DeviceNet master (scanner) implementation.\u003c\/li\u003e\n  \u003cli\u003eSupports standard transmission rates of 125, 250, and 500 kbaud.\u003c\/li\u003e\n  \u003cli\u003eControls up to 63 connected DeviceNet fieldbus slaves.\u003c\/li\u003e\n  \u003cli\u003eGalvanically decoupled 5-pin open style connection interface.\u003c\/li\u003e\n  \u003cli\u003eHardware-based diagnostics via status LEDs for rapid troubleshooting.\u003c\/li\u003e\n  \u003cli\u003eCompact, space-saving 24 mm terminal housing with integrated DIN-rail release.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFactory automation and legacy machinery migration.\u003c\/li\u003e\n  \u003cli\u003eAutomotive assembly line tool integration.\u003c\/li\u003e\n  \u003cli\u003eProcess control systems utilizing distributed DeviceNet I\/O.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and material handling systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\n      \u003ctd\u003eEL6752\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eTechnology\u003c\/strong\u003e\n      \u003ctd\u003eDeviceNet master terminal (scanner)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\n      \u003ctd\u003e1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eData Transfer Rates\u003c\/strong\u003e\n      \u003ctd\u003e125, 250, 500 kbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eInterface Type\u003c\/strong\u003e\n      \u003ctd\u003e5-pin open-style connector (included), galvanically decoupled\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eMax. Number of Slaves\u003c\/strong\u003e\n      \u003ctd\u003e63 slaves\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCurrent Consumption (E-bus)\u003c\/strong\u003e\n      \u003ctd\u003etyp. 260 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eHardware Diagnostics\u003c\/strong\u003e\n      \u003ctd\u003eStatus LEDs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\n      \u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\n      \u003ctd\u003e95 %, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eVibration\/Shock Resistance\u003c\/strong\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eEMC Immunity\/Emission\u003c\/strong\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProtection Rating\u003c\/strong\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eHousing Material\u003c\/strong\u003e\n      \u003ctd\u003ePolycarbonate\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\n      \u003ctd\u003e24 mm x 100 mm x 52 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWeight\u003c\/strong\u003e\n      \u003ctd\u003eapprox. 70 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Pin\u003c\/th\u003e\n      \u003cth\u003eSignal \/ Function\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e1\u003c\/td\u003e\n      \u003ctd\u003eV- (DeviceNet Power Supply Ground)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n      \u003ctd\u003eCAN_L (CAN Low Signal)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e3\u003c\/td\u003e\n      \u003ctd\u003eShield (Drain wire connection)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e4\u003c\/td\u003e\n      \u003ctd\u003eCAN_H (CAN High Signal)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e5\u003c\/td\u003e\n      \u003ctd\u003eV+ (DeviceNet Power Supply +24 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount horizontally or vertically on a standard 35 mm DIN rail conforming to EN 60715. Use the integrated locking mechanism for secure placement.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use specialized push-in connections for E-bus communication and the provided 5-pin open style connector for DeviceNet cabling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Grounding:\u003c\/strong\u003e Ensure the DeviceNet cable shield is properly terminated at the connector to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e Maintain operating ambient temperature within -25 degC to +60 degC. Ensure the installation cabinet provides adequate ventilation to achieve an IP20 rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003eATEX: II 3 G Ex nA IIC T4 Gc\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106480578923,"sku":"EL6752","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/el6752-dgpu5lpqe1x.png?v=1776244562","url":"https:\/\/www.plcprotech.com\/de\/products\/beckhoff-el6752-ethercat-terminal-devicenet-master-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}