{"product_id":"beckhoff-ip1502-b510-fieldbus-box-2-channel-digital-input-counter-module","title":"BECKHOFF IP1502-B510 Fieldbus Box 2-Channel Digital Input Counter Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for high-speed pulse processing and count-rate evaluation directly in harsh industrial environments, the \u003cstrong\u003eBECKHOFF IP1502-B510\u003c\/strong\u003e is a CANopen-compatible \u003cstrong\u003eFieldbus Box\u003c\/strong\u003e featuring dual high-frequency counter channels. This decentralised module operates independently of control cabinets, collecting and processing rapid digital signals directly on the machinery. With two independent 32-bit counter inputs, integrated gate controls, and direction-switching inputs, it provides highly responsive feedback for motion and flow tracking systems.\u003c\/p\u003e\n\n\u003cp\u003eThe unit integrates seamlessly into CANopen networks using standard M12 industrial connections, offering automatic baud rate detection from 10 kbaud up to 1 Mbaud. Enclosed in a robust polyamide housing with IP65\/66\/67 ingress protection, this module stands up to dust, moisture, and high vibration, facilitating reliable performance in demanding material handling and manufacturing installations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDual 32-bit digital counter inputs operating up to 100 kHz.\u003c\/li\u003e\n  \u003cli\u003eIntegrated gate inputs and up\/down direction control switches.\u003c\/li\u003e\n  \u003cli\u003eSeamless integration with CANopen network protocols using up to 16 send and 16 receive PDOs.\u003c\/li\u003e\n  \u003cli\u003eAutomatic baud rate detection spanning 10 kbaud to 1 Mbaud.\u003c\/li\u003e\n  \u003cli\u003ePower supply routing via dual M8 connections (feed and downstream loop).\u003c\/li\u003e\n  \u003cli\u003eRobust IP65, IP66, and IP67 protection ratings for direct on-machine mounting.\u003c\/li\u003e\n  \u003cli\u003eConfigurable parameters accessible via the KS2000 software tool or standard service data objects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRotary encoder and high-speed pulse-train monitoring in materials handling.\u003c\/li\u003e\n  \u003cli\u003eTurbine flow meter integration in water treatment and process plants.\u003c\/li\u003e\n  \u003cli\u003eHigh-speed component counting on packaging and bottling lines.\u003c\/li\u003e\n  \u003cli\u003eDecentralised position tracking and velocity measurement in heavy machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP1502-B510\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box (Counter Module)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFieldbus Protocol\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCANopen\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Counter Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAdditional Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 gate inputs, 2 up\/down switches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCounter Depth\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e32 bits per channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Counting Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100 kHz (2 kHz for up\/down switching)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e0 Signal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-3 to +5 V (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e1 Signal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11 to 30 V (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 x 24 V DC, 0.5 A (short-circuit proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMax. 0.5 A total (short-circuit proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Connections\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male (4-pin); Downstream: 1 x M8 female (4-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBus Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 plug (5-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInternal Box Supply Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mA + sensor current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: 500 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIngress Protection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP65\/66\/67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration\/Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyamide (PA6)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e30 mm x 175 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnector Type\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM12 (5-pin plug)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCANopen network interface\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM12 (Screw-type)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSignal connections (Counters, gate inputs, and switches)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM8 (4-pin male)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIncoming 24 V DC power supply feed\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM8 (4-pin female)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDownstream power distribution loop\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the unit directly to machine structures or structural profiles using the two integrated 3.5 mm diameter fixing holes designed for M3 hardware.\u003c\/li\u003e\n  \u003cli\u003eEnsure all unused M12 and M8 connector sockets are sealed with protective threaded caps to preserve the IP65\/66\/67 environmental rating.\u003c\/li\u003e\n  \u003cli\u003eEmploy shielded copper twisted-pair cabling for the CANopen transmission network to maintain noise immunity.\u003c\/li\u003e\n  \u003cli\u003eIsolate low-voltage signal\/bus cabling from high-power distribution lines and dynamic motor drives.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106470551915,"sku":"IP1502-B510","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1502-b510-40jpqcy403y.png?v=1776244906","url":"https:\/\/www.plcprotech.com\/de\/products\/beckhoff-ip1502-b510-fieldbus-box-2-channel-digital-input-counter-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}