{"product_id":"beckhoff-ip2312-b800-fieldbus-box-digital-i-o-module","title":"BECKHOFF IP2312-B800 Fieldbus Box Digital I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for decentralized automation environments, the Beckhoff \u003cstrong\u003eIP2312-B800\u003c\/strong\u003e is a ruggedized \u003cstrong\u003edigital I\/O fieldbus box\u003c\/strong\u003e that facilitates direct signal interfacing in the field without the need for a protective control cabinet. This module integrates a balanced combination of four digital inputs and four digital outputs, communicating via a reliable RS485 physical interface.\u003c\/p\u003e\n\n\u003cp\u003eThe unit features robust M12 connections, allowing for secure and quick cabling of field devices and network communication. Designed to withstand harsh industrial conditions, the \u003cstrong\u003eIP2312-B800\u003c\/strong\u003e is ideal for localized control structures where fast signal acquisition (0.2 ms input filter) and reliable actuator switching (0.5 A per output channel) are required.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFour digital inputs with a fast 0.2 ms signal filter to ensure accurate pulse detection.\u003c\/li\u003e\n  \u003cli\u003eFour digital outputs sourcing up to 0.5 A per channel at 24 V DC.\u003c\/li\u003e\n  \u003cli\u003eRS485 interface optimized for serial industrial fieldbus protocols.\u003c\/li\u003e\n  \u003cli\u003eIndustrial-grade M12 screw connectors for secure signal, power, and bus routing.\u003c\/li\u003e\n  \u003cli\u003eHighly durable IP67-rated enclosure resistant to dust, moisture, and mechanical vibrations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized conveyor systems and material handling routing.\u003c\/li\u003e\n  \u003cli\u003eMachine-mount sensor\/actuator hubs in automotive and manufacturing assembly lines.\u003c\/li\u003e\n  \u003cli\u003eFood processing and packaging facilities requiring washdown protection.\u003c\/li\u003e\n  \u003cli\u003eDistributed remote I\/O processing over long-distance RS485 links.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\/Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP2312-B800\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box I\/O Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRS485\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 channels (24 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Filter Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.2 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 channels (24 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 A per channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection Technology\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM12 round connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP67\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Type\u003c\/th\u003e\n      \u003cth\u003eConnector Style\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFieldbus\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM12\u003c\/td\u003e\n      \u003ctd\u003eRS485 Incoming and Outgoing lines\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM12\u003c\/td\u003e\n      \u003ctd\u003eChannels 0 to 3 for 24 V DC sensors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM12\u003c\/td\u003e\n      \u003ctd\u003eChannels 0 to 3 for 24 V DC \/ 0.5 A actuators\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM8 \/ M12\u003c\/td\u003e\n      \u003ctd\u003e24 V DC control voltage input and downstream feed\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the module directly to the machine frame or flat surfaces using the integrated mounting holes. Ensure the mounting surface is clean and level.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the functional ground (FE) directly to the machine potential via low-resistance grounding straps.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Spec:\u003c\/strong\u003e Hand-tighten all M12 and M8 connections, then apply the specified torque of 0.6 Nm using an industrial torque wrench to maintain the IP67 protective seal.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabling:\u003c\/strong\u003e Keep signal and communication cables separate from high-voltage AC lines to prevent electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106495127915,"sku":"IP2312-B800","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2312-b800-tcsrvo30zma.png?v=1776245031","url":"https:\/\/www.plcprotech.com\/de\/products\/beckhoff-ip2312-b800-fieldbus-box-digital-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}