{"product_id":"beckhoff-ip4112-b520-fieldbus-box","title":"Beckhoff IP4112-B520 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for rugged industrial environments, the \u003cstrong\u003eIP4112-B520\u003c\/strong\u003e extension module integrates high-performance I\/O capabilities directly into standard DeviceNet systems. This \u003cstrong\u003efieldbus box\u003c\/strong\u003e enables decentralized signal acquisition and processing directly on the machinery, bypassing the need for a protective control cabinet. By utilizing robust connection interfaces and automated communication setups, it provides an efficient link between physical field devices and the master controller.\u003c\/p\u003e\n\n\u003cp\u003eThe module facilitates seamless transmission of peripheral signals while ensuring maximum noise immunity through galvanic isolation. Configuration is simplified, allowing engineers to manage parameters either through the dedicated KS2000 software interface or via standard PLC explicit messaging. Its physical construction features an ingress protection rating up to IP67, making it highly resilient against liquid splashes, dust, and mechanical stress in demanding production facilities.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDeviceNet Integration:\u003c\/strong\u003e Full compatibility with DeviceNet industrial networks, utilizing a 5-pin M12 connection interface.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic Baud Rate Detection:\u003c\/strong\u003e Automatically identifies network speed up to 500 kbaud, reducing setup times.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Housing:\u003c\/strong\u003e Sealed IP65\/66\/67 enclosure designed for direct machine installation without control cabinets.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimplified Wiring:\u003c\/strong\u003e Power supply feed and downstream connections implemented via standardized 4-pin M8 ports.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Configuration:\u003c\/strong\u003e Supports parameters adjustment using KS2000 configuration software or direct controller-explicit messaging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHeavy machinery manufacturing and decentralized assembly lines.\u003c\/li\u003e\n  \u003cli\u003eAutomotive manufacturing facilities utilizing DeviceNet networks.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling systems and outdoor conveyor installations.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater processing equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBeckhoff\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP4112-B520\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box (DeviceNet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Transfer Rates\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAutomatic detection up to 500 kbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 plug, 5-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Transfer Medium\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eShielded copper cable, with power supply, typ. 2 x 2 x 0.25 mm2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Voltage Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBox Supply Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mA + sensor consumption (max. 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: 500 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eI\/O Communication Types\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBit strobe, polling, cyclic, change of state\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration \/ Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity \/ Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP65 \/ IP66 \/ IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 kg (approx.)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Type\u003c\/th\u003e\n      \u003cth\u003eConnection Standard\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus Connection\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 plug (5-pin)\u003c\/td\u003e\n      \u003ctd\u003eDeviceNet communication bus line interface\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Feed\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 male socket (4-pin)\u003c\/td\u003e\n      \u003ctd\u003eInput terminal for 24 V DC control and load voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Downstream\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 female socket (4-pin)\u003c\/td\u003e\n      \u003ctd\u003eLoop-through connection to power subsequent fieldbus boxes\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the module securely to the machinery frame using the integrated mounting holes. Variable mounting positions are supported.\u003c\/li\u003e\n  \u003cli\u003eEnsure the use of standard shielded copper cables (typ. 2 x 2 x 0.25 mm2) for data lines to maintain EMC compliance and prevent communication errors.\u003c\/li\u003e\n  \u003cli\u003eTo achieve the rated IP65\/66\/67 protection, seal all unused M8 and M12 connection ports with certified protective caps.\u003c\/li\u003e\n  \u003cli\u003eMaintain a physical installation structure that does not exceed the maximum DeviceNet bus line distances specified for your network configuration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106423693675,"sku":"IP4112-B520","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip4112-b520-p0nkext50xs.png?v=1776245096","url":"https:\/\/www.plcprotech.com\/de\/products\/beckhoff-ip4112-b520-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}