{"product_id":"beckhoff-ip5109-b318-fieldbus-box-module","title":"BECKHOFF IP5109-B318 Fieldbus Box Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDecentralized signal processing in harsh industrial environments requires robust, field-mountable input\/output modules that eliminate the need for protective control cabinets. The \u003cstrong\u003eIP5109-B318\u003c\/strong\u003e \u003cstrong\u003eFieldbus Box\u003c\/strong\u003e provides a direct connection to PROFIBUS DP networks, permitting reliable high-speed data transmission directly on the machinery. Designed with integrated M12 bus interfaces and M8 power connections, this module enables rapid installation and seamless integration into existing control architectures. Configuration of the device can be executed directly through the master controller or via the specialized KS2000 software suite, which fully supports DP-V1 extensions for parameterized operation.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic Baud Rate Detection:\u003c\/strong\u003e Automatically adjusts and synchronizes to network transfer speeds up to 12 Mbaud.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated T-Connector:\u003c\/strong\u003e Features a dual M12 interface (plug and socket) minimizing additional network cabling and external splitting hardware.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Environmental Protection:\u003c\/strong\u003e IP65, IP66, and IP67 ingress protection ratings allow mounting directly on equipment without an enclosure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Parameterization:\u003c\/strong\u003e Supports standard DP-V1 acyclic communication and configuration through KS2000.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Pass-Through:\u003c\/strong\u003e M8 power connectors allow daisy-chaining control and load voltages to downstream modules, reducing wiring complexity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomotive assembly lines and conveyor systems\u003c\/li\u003e\n  \u003cli\u003eMaterial handling and sorting systems\u003c\/li\u003e\n  \u003cli\u003eFood processing and packaging machinery\u003c\/li\u003e\n  \u003cli\u003eWastewater treatment facility distributed automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP5109-B318\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtocol \/ Fieldbus\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS DP, DP-V1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Transfer Rates\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUp to 12 Mbaud (automatic detection)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBus Interface Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 socket (5-pin, B-coded), 1 x M12 plug (5-pin, B-coded, integrated T-connector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Transfer Medium\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eShielded copper cable, 2 x 0.25 square millimeters\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Voltage Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLoad Voltage Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDetermined by I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Connections\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBox Supply Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85 mA + sensor current consumption (maximum 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: No; Control voltage\/inputs-outputs: Dependent on I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Transfer Cycle Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApproximately 0.5 ms with 10 stations (each 32-bit input\/output)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration \/ Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity \/ Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Type\u003c\/th\u003e\n      \u003cth\u003eConnector Style\u003c\/th\u003e\n      \u003cth\u003ePin Count \u0026amp; Coding\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus Input (Bus In)\u003c\/td\u003e\n      \u003ctd\u003eM12 Plug\u003c\/td\u003e\n      \u003ctd\u003e5-pin, B-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus Output (Bus Out)\u003c\/td\u003e\n      \u003ctd\u003eM12 Socket\u003c\/td\u003e\n      \u003ctd\u003e5-pin, B-coded (integrated tee)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Feed\u003c\/td\u003e\n      \u003ctd\u003eM8 Male\u003c\/td\u003e\n      \u003ctd\u003e4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Downstream\u003c\/td\u003e\n      \u003ctd\u003eM8 Female\u003c\/td\u003e\n      \u003ctd\u003e4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that the mounting surface is clean and flat to maintain the unit's ingress protection. Secure the module using the integrated mounting holes. When routing cables, avoid sharp bends and keep signal cables separate from high-power load lines to prevent electromagnetic interference. All unused M12 and M8 connection ports must be sealed using certified protective caps to maintain the IP65\/66\/67 environmental rating. Properly ground the fieldbus shield according to standard Profibus installation recommendations.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106449973611,"sku":"IP5109-B318","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip5109-b318-3hfi2i0ms12.png?v=1776245107","url":"https:\/\/www.plcprotech.com\/de\/products\/beckhoff-ip5109-b318-fieldbus-box-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}