{"product_id":"beckhoff-km1018-0001-bus-terminal-digital-input-module","title":"Beckhoff KM1018-0001 Bus Terminal Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eHigh-density digital signal processing within the Beckhoff I\/O system is efficiently managed by the \u003cstrong\u003eKM1018-0001\u003c\/strong\u003e Bus Terminal module. This compact 64-channel digital input module is engineered to capture binary control signals from the physical field level and transmit them with electrical isolation to the higher-level K-bus controller. With its high channel density and pluggable wiring configuration, this terminal module significantly reduces control cabinet footprint requirements while maintaining robust signal integrity.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eBeckhoff KM1018-0001\u003c\/strong\u003e features a fast input filter time of typically 0.2 ms, making it highly suitable for applications demanding rapid state detection. Connection to the field inputs is established via a pluggable 1-wire connector level, enabling easy pre-assembly of the wiring harness and reducing downtime during maintenance. The module integrates seamlessly into standard DIN rail configurations, communicating directly with the process image through a 64-bit width mapping without requiring complex parameterization.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e64 digital inputs structured in 8 groups of 8 channels.\u003c\/li\u003e\n  \u003cli\u003eFast input filter of typically 0.2 ms for high-speed signal capture.\u003c\/li\u003e\n  \u003cli\u003ePluggable 1-wire connection interface simplifies wiring and deployment.\u003c\/li\u003e\n  \u003cli\u003eGalvanic isolation of 500 V between the K-bus and the field potential.\u003c\/li\u003e\n  \u003cli\u003eCompact terminal block housing featuring double slot and key alignment for robust mounting.\u003c\/li\u003e\n  \u003cli\u003eNo address settings or software configuration required for standard startup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-density electrical cabinet integration.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and automated assembly lines.\u003c\/li\u003e\n  \u003cli\u003eMulti-axis machine tool automation.\u003c\/li\u003e\n  \u003cli\u003eDistributed sensor arrays in manufacturing plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eModel Number\u003c\/th\u003e\n      \u003cth\u003eConfiguration\u003c\/th\u003e\n      \u003cth\u003eConnector Included\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKM1018-0000\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e64-channel digital input, 24 V DC, 0.2 ms filter\u003c\/td\u003e\n      \u003ctd\u003eWithout pluggable connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKM1018-0001\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e64-channel digital input, 24 V DC, 0.2 ms filter\u003c\/td\u003e\n      \u003ctd\u003e1-wire connector included\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKM1018-0002\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e64-channel digital input, 24 V DC, 0.2 ms filter\u003c\/td\u003e\n      \u003ctd\u003e1-wire connector with status LEDs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKM1018-0004\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e64-channel digital input, 24 V DC, 0.2 ms filter\u003c\/td\u003e\n      \u003ctd\u003e3-wire connector with status LEDs\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBeckhoff Automation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eKM1018-0001\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e64 (8 x 8)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e\"0\" Signal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-3 to +5 V (conforms to EN 61131-2, type 1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e\"1\" Signal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15 to 30 V (conforms to EN 61131-2, type 1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Filter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 0.2 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 5 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption K-Bus\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 3 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 V (K-bus \/ field potential)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBit Width in Process Image\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e64 inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e123 mm x 100 mm x 55 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eapprox. 310 g (including 1-pin connector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration\/Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity\/Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Interface\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n      \u003cth\u003eConnection Properties\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eX1 to X8 Connectors\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 groups of 8 digital inputs\u003c\/td\u003e\n      \u003ctd\u003ePluggable, 1-wire connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWire Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSolid\/stranded conductors\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 1.5 mm²\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStripping Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConductor preparation\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Attach to a standard 35 mm DIN rail conforming to EN 60715 using the integrated locking tab.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAlignment:\u003c\/strong\u003e Place side-by-side with adjacent K-bus terminals using the double slot and key connection points for optimal structural stability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Route signals using 1-wire plug connectors. Ensure wire terminations are stripped to exactly 8 mm before terminal insertion.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Grounding:\u003c\/strong\u003e Ensure the mounting rail is clean, paint-free, and adequately grounded to provide low-impedance pathways for EMC transients.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106463048043,"sku":"KM1018-0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/KM1018-0001-Beckhoff-Bus-Terminal-module-64-channel-digital-input-24-V-DC-3-ms-1-wire-connector-b23xbuf5gdw.png?v=1776245250","url":"https:\/\/www.plcprotech.com\/de\/products\/beckhoff-km1018-0001-bus-terminal-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}