{"product_id":"beckhoff-ks4434-bus-terminal","title":"BECKHOFF KS4434 Bus Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for precise analog automation control, the \u003cstrong\u003eBECKHOFF KS4434\u003c\/strong\u003e analog output terminal delivers four channels of high-resolution control signals. Operating within a standard range of -10 to +10 V, this \u003cstrong\u003ebus terminal\u003c\/strong\u003e features single-ended circuitry designed to drive analog actuators, control valves, and speed-controlled motor drives with precision.\u003c\/p\u003e\n\n\u003cp\u003eA defining feature of the KS series is its pluggable wiring level, enabling fast, tool-free module replacement without disrupting existing system wiring. Integrating seamlessly into the Beckhoff K-bus system, the module transmits electrically isolated signals back to the automation controller, maintaining process stability and protecting sensitive upstream components from electrical noise.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFour single-ended analog output channels.\u003c\/li\u003e\n  \u003cli\u003eStandard bipolar voltage signal range of -10 to +10 V.\u003c\/li\u003e\n  \u003cli\u003e12-bit analog resolution for fine control loop adjustments.\u003c\/li\u003e\n  \u003cli\u003ePluggable connection level for swift, minimized-downtime maintenance.\u003c\/li\u003e\n  \u003cli\u003eShort-circuit proof outputs with active load protection above 5 kOhm.\u003c\/li\u003e\n  \u003cli\u003eRobust electrical isolation rated up to 500 V between K-bus and signal circuits.\u003c\/li\u003e\n  \u003cli\u003eDirect DIN rail installation with reliable double-slot side-by-side locking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial machinery and process control systems.\u003c\/li\u003e\n  \u003cli\u003eVariable frequency drive speed setting regulation.\u003c\/li\u003e\n  \u003cli\u003eProportional valve control in hydraulic and pneumatic systems.\u003c\/li\u003e\n  \u003cli\u003eHVAC ventilation, damper, and actuator positioning.\u003c\/li\u003e\n  \u003cli\u003eOEM manufacturing lines and assembly automation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003eSystem \u0026amp; Electrical Parameters\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eKS4434\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSignal Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-10 to +10 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Load\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026gt; 5 kOhm (short-circuit proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Error\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; +\/-0.1 % (relative to full-scale value)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 bit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConversion Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e~ 4 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 V (K-bus \/ signal voltage)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption K-bus\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTyp. 20 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProcess Image Bit Width\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOutput: 4 x 16-bit data (optional 4 x 8-bit control\/status)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Load Power Contacts\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMax. 10 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003eMechanical \u0026amp; Environmental Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection Technology\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSpring actuation (tension clamp)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSolid Wire Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 1.5 mm² (AWG 28 to 16)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFine-Strand Wire Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.14 to 1.5 mm² (AWG 26 to 16)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStripping Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9 to 10 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 mm x 100 mm x 68 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.075 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolycarbonate\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e35 mm DIN rail (EN 60715) with lock\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the bus terminal horizontally or vertically on a standard 35 mm DIN rail. Secure the terminal using the integrated lock mechanism.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use a flat-blade screwdriver to open the spring clamp terminal. Insert the stripped wire (9 to 10 mm stripping length) and release the clamp.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Grounding:\u003c\/strong\u003e Ensure the analog signal cables are properly shielded to prevent electromagnetic interference from surrounding power circuits. Connect the shield to the ground plane closest to the entry point.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePluggable Level:\u003c\/strong\u003e When servicing, slide the pluggable terminal connector out of the housing to disconnect wiring safely without terminal-by-terminal rewiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003eATEX: II 3 G Ex nA IIC T4 Gc\u003c\/li\u003e\n  \u003cli\u003eDNV GL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106529272171,"sku":"KS4434","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ks4434-ecbcy4nlyid.png?v=1776245325","url":"https:\/\/www.plcprotech.com\/de\/products\/beckhoff-ks4434-bus-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}