{"product_id":"bently-nevada-330101-00-30-50-02-00-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-00-30-50-02-00 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for non-contact machinery protection, the \u003cstrong\u003eBently Nevada 330101-00-30-50-02-00\u003c\/strong\u003e is a high-performance \u003cstrong\u003e8 mm proximity probe\u003c\/strong\u003e engineered to measure static and dynamic shaft displacement on critical rotating machinery. As an integral component of the 3300 XL 8 mm Proximity Transducer System, this probe operates on the eddy-current principle to provide precise, continuous vibration and position measurements. This specific configuration features a fully threaded 3.0-inch stainless steel case without unthreaded length, making it ideal for standard forward-mount installations that require a secure, direct fit into threaded machine housings.\u003c\/p\u003e\n\n\u003cp\u003eThe 330101-00-30-50-02-00 variant is distinctively configured with a 5.0-meter (16.4 feet) total length standard cable, allowing it to interface directly with a 5-meter Proximitor sensor without the need for an intermediate extension cable. This direct-connect configuration reduces physical connection points, simplifying the measurement loop and increasing system reliability. Equipped with a miniature coaxial ClickLoc connector and standard FEP-insulated triaxial cable, this unarmored probe provides robust mechanical stability and high chemical resistance in demanding industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEddy-current measurement principle for non-contact, wear-free shaft vibration and position monitoring.\u003c\/li\u003e\n  \u003cli\u003eDirect-connect 5.0-meter total cable length, engineered specifically for direct pairing with 5-meter Proximitor sensors.\u003c\/li\u003e\n  \u003cli\u003eFully threaded 3.0-inch case length (0.0-inch unthreaded) with standard 3\/8-24 UNF-2A threads for precise adjustment.\u003c\/li\u003e\n  \u003cli\u003eRugged polyphenylene sulfide (PPS) probe tip and AISI 303\/304 stainless steel body for harsh machine environments.\u003c\/li\u003e\n  \u003cli\u003eStandard unarmored FEP-insulated coaxial cable for excellent flexibility and resistance to corrosive industrial fluids.\u003c\/li\u003e\n  \u003cli\u003eMiniature coaxial ClickLoc connector ensures a secure, reliable electrical connection with minimal signal degradation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam and gas turbine shaft vibration and axial position measurement.\u003c\/li\u003e\n  \u003cli\u003eRotor displacement monitoring in centrifugal compressors, expanders, and industrial pumps.\u003c\/li\u003e\n  \u003cli\u003eGenerator bearing oil film clearance and shaft dynamic motion analysis.\u003c\/li\u003e\n  \u003cli\u003eMachine speed and Keyphasor reference measurements on high-speed rotating equipment.\u003c\/li\u003e\n  \u003cli\u003ePermanent machine protection in power generation, oil and gas, and petrochemical facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330101-00-30-50-02-00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption A: Unthreaded Length\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 inches (0 mm) unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption B: Overall Case Length\u003c\/td\u003e\n      \u003ctd\u003e30\u003c\/td\u003e\n      \u003ctd\u003e3.0 inches (76 mm) case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption C: Total Length\u003c\/td\u003e\n      \u003ctd\u003e50\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet) total probe length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption D: Connector and Cable Type\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOption E: Agency Approval\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo agency approvals required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSpecification Parameter\u003c\/th\u003e\n      \u003cth\u003eValue \/ Detail\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\/Model\u003c\/td\u003e\n      \u003ctd\u003e330101-00-30-50-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Family\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Diameter\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThread Size\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eArmor Option\u003c\/td\u003e\n      \u003ctd\u003eWithout Armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCase Length\u003c\/td\u003e\n      \u003ctd\u003e3.0 in (76 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTotal Length\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal DC Resistance (R_PROBE)\u003c\/td\u003e\n      \u003ctd\u003e8.73 ohms (center conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Principle\u003c\/td\u003e\n      \u003ctd\u003eEddy current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMeasurement Type\u003c\/td\u003e\n      \u003ctd\u003eDisplacement (proximity)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Type\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStandard Target Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 4140 steel (calibrated target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating and Storage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Case Torque\u003c\/td\u003e\n      \u003ctd\u003e11.2 N-m (100 in-lbf)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Rated Case Torque\u003c\/td\u003e\n      \u003ctd\u003e33.9 N-m (300 in-lbf)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Connector Torque\u003c\/td\u003e\n      \u003ctd\u003e0.565 N-m (5 in-lbf)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Cable Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tensile Strength (Max)\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lbf) probe case to probe lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n      \u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure the probe is mounted with the appropriate probe gap set in accordance with system calibration (typically 1.27 mm or 50 mils for standard linear range).\u003c\/li\u003e\n  \u003cli\u003eEnsure the mechanical mounting location does not exceed maximum rated torque limits when tightening the probe case into the machine housing. Standard recommended torque is 11.2 N-m (100 in-lbf).\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum cable bend radius of 25.4 mm (1.0 in) during routing to prevent internal damage to the coaxial core and shield.\u003c\/li\u003e\n  \u003cli\u003eAlways route the probe cable away from sources of high-frequency electromagnetic interference and use proper shielding and grounding practices.\u003c\/li\u003e\n  \u003cli\u003eThis 5.0-meter probe must be connected directly to a 5-meter Proximitor sensor only; do not add an extension cable to this configuration as it will alter the system's electrical length and disrupt calibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis product is designed and manufactured in accordance with strict industrial quality standards. For this specific non-approved configuration (Option E: 00), hazardous area certifications are not included. The probe is intended for general-purpose industrial environments where explosive atmospheres are not present.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666862928235,"sku":"330101-00-30-50-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-00-30-50-02-00-proximity-probes-zdv5404j2zz_13a3a232-1a9e-44c2-a5b7-93f377eba1da.jpg?v=1765449351","url":"https:\/\/www.plcprotech.com\/de\/products\/bently-nevada-330101-00-30-50-02-00-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}