{"product_id":"bently-nevada-330104-00-13-10-02-cn-3300-xl-8mm-proximity-probe","title":"Bently Nevada 330104-00-13-10-02-CN 3300 XL 8mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding critical shaft dynamic displacement and position data for machinery protection systems, the \u003cstrong\u003eBently Nevada 330104-00-13-10-02-CN\u003c\/strong\u003e operates as a ruggedized non-contacting transducer within the \u003cstrong\u003e3300 XL 8mm Series\u003c\/strong\u003e. This proximity probe is specifically engineered to measure radial vibration, axial thrust, and phase reference on high-speed rotating shafts. Utilizing a highly resilient Polyphenylene sulfide (PPS) tip and an AISI 303\/304 stainless steel threaded body, it maintains electrical and mechanical stability under severe operating conditions, such as those found in steam turbines, gas turbines, and large industrial compressors.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Tip Protection:\u003c\/strong\u003e Molded Polyphenylene sulfide (PPS) tip resists chemical degradation, oil penetration, and high operating temperatures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Mechanical Design:\u003c\/strong\u003e Metric M10x1 thread configuration with 130mm overall case length for precise positioning inside tight machine housings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClickLoc Connector System:\u003c\/strong\u003e Equipped with a gold-plated miniature coaxial ClickLoc connector, preventing accidental disconnection while ensuring minimal signal attenuation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Stability Signal:\u003c\/strong\u003e Designed for seamless integration with 3300 XL Proximitor Sensors to achieve a standard 200 mV\/mil (7.87 V\/mm) linear scale factor.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCN Certification:\u003c\/strong\u003e Certified with country-specific hazardous area approvals for safe deployment in volatile industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eContinuous radial vibration monitoring of fluid-film bearings.\u003c\/li\u003e\n  \u003cli\u003eThrust position measurements on critical turbomachinery.\u003c\/li\u003e\n  \u003cli\u003eSpeed sensing and Keyphasor phase reference tracking.\u003c\/li\u003e\n  \u003cli\u003eAsset condition monitoring in petrochemical, power generation, and refining facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e330104-00-13-10-02-CN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProbe Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3300 XL 8 mm Proximity Probe\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eThread Configuration\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMetric M10 x 1 (Standard Case)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eUnthreaded Length Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e00 (0 mm unthreaded portion)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOverall Case Length Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e13 (130 mm overall case length)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTotal Length Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e10 (1.0 meter \/ 3.3 feet total cable length)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eConnector and Cable Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e02 (Miniature coaxial ClickLoc connector, standard cable)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAgency Approvals\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCN (Country-specific hazardous location and explosion protection)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProbe Tip Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProbe Case Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAISI 303 or 304 Stainless Steel (SST)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eLinear Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2.0 mm (80 mils), starting at approx 0.25 mm (10 mils) from target\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSystem Sensitivity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e7.87 V\/mm (200 mV\/mil) when combined with standard AISI 4140 steel target\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-51 Celsius to +177 Celsius (-60 Fahrenheit to +350 Fahrenheit)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUnited States (U.S.A.)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2.00 kg (with industrial packaging)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eConnection Component\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eInterface \u0026amp; Function\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCoaxial Center Pin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eTransmits high-frequency RF signal from the Proximitor; carries dynamic AC\/DC voltage feedback.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOuter ClickLoc Collar\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCommon\/Shield return line. Provides physical mechanical locking and environmental sealing.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eM10 Threaded Body\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRigid physical ground connection to the machine housing when locked with a structural jam nut.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 1.0-meter probe system must always be paired with a corresponding 3300 XL extension cable (either 4.0 meters or 8.0 meters) to match the calibration path of 5.0-meter or 9.0-meter Proximitor systems. Connecting a 1.0-meter probe directly or using incorrect cable lengths will result in severe calibration errors and incorrect displacement measurements. If replacing an older, non-XL 3300 probe, verify that the Proximitor has been upgraded, as mismatching XL and non-XL components degrades linear tracking performance.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEnsure that the mounting location has a minimum clearance of 40 mm (1.6 inches) diameter of flat surface around the probe tip to prevent side-loading. Side-loading, caused by the proximity of adjacent structural metal, creates parasitic magnetic fields that shift the baseline gap voltage. Additionally, check that the target material is AISI 4140 steel; other alloys will alter the nominal 200 mV\/mil scale factor and require custom calibration curves.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen connecting the miniature coaxial ClickLoc connector, align the interfaces and press firmly together until the dynamic connection clicks into place. Avoid using pliers or heavy mechanical wrenches on the connector housing, as over-tightening or crushing the thin-wall connector destroys the gold-plated contact pins. Use silicone connector boot assemblies if the connection is directly exposed to synthetic turbine oil or solvent sprays.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e De-energize the monitoring system and isolate the rotating machinery prior to installing or adjusting the proximity probe. High electrostatic charges or stray voltages in the turbine housing can cause equipment damage or ignition risks in explosive environments. Always verify area safety permits before opening junction boxes.\n\u003c\/div\u003e\n\n\u003col style=\"list-style: none; padding-left: 0; color: #2d3748;\"\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003eInspect the M10 machine threads to ensure they are clean, dry, and free of metallic debris that could cause galling.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003eThread the probe into the mounting bracket or sleeve while tracking the gap voltage using a calibrated multimeter hooked to the Proximitor OUT and COM terminals. Adjust physical depth until the voltage reads approximately -10.0 Vdc (the linear midpoint).\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003eLock the probe in place by tightening the external jam nut. Torque the locknut to the recommended OEM specification without shifting the probe body.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003eRoute the coaxial cable through structural protective conduit to avoid physical abrasion or EMI noise coupling from power cables. Secure the ClickLoc connection to the extension cable and wrap with self-amalgamating tape if oil exposure is expected.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668292661611,"sku":"330104-00-13-10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330104-00-13-10-02-CN-a4jpfdm5htt_82f5647b-450c-4d8b-a474-de244eb232f1.jpg?v=1765520364","url":"https:\/\/www.plcprotech.com\/de\/products\/bently-nevada-330104-00-13-10-02-cn-3300-xl-8mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}