{"product_id":"bently-nevada-330130-085-03-cn-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-085-03-CN 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBridging critical high-frequency signals within machinery protection loops, the \u003cstrong\u003eBently Nevada 330130-085-03-CN\u003c\/strong\u003e serves as the vital link between a 3300 XL 8mm proximity probe and a compatible Proximitor sensor. This \u003cstrong\u003e8.5-meter\u003c\/strong\u003e coaxial extension cable is constructed with robust \u003cstrong\u003estainless steel armor\u003c\/strong\u003e and integrated \u003cstrong\u003econnector protectors\u003c\/strong\u003e, specifically engineered to withstand harsh chemical, mechanical, and thermal conditions in industrial environments. By maintaining precise system capacitance and impedance, it ensures noise-free transmission of dynamic vibration and position signals to keep critical turbomachinery monitored and protected.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Armor:\u003c\/strong\u003e Flexible stainless steel armor outer jacket protects the inner coaxial core from hot chips, abrasive friction, and mechanical damage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Connector Protectors:\u003c\/strong\u003e Installed on the connectors to prevent contamination by dust, moisture, and cutting fluids, while securing the physical coaxial connection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCalibrated Impedance:\u003c\/strong\u003e Matched electrical length and capacitance to prevent signal reflection and ensure total accuracy across the entire frequency range.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGold-Plated Coaxial Interfaces:\u003c\/strong\u003e Provides reliable connection points with minimal contact resistance, minimizing signal degradation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approval:\u003c\/strong\u003e CN-designated option ensures conformity to specific local explosive atmosphere regulations for safe deployment in hazardous industrial zones.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eSteam and gas turbine bearing vibration and radial position monitoring.\u003c\/li\u003e\n  \u003cli\u003eCentrifugal compressor shaft vibration and axial thrust measurements.\u003c\/li\u003e\n  \u003cli\u003eIndustrial gearboxes, pumps, and high-speed generator shaft displacement sensing.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection systems operating in petrochemical refineries and power generation plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e330130-085-03-CN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3300 XL\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCable Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e8.5 meters (27.9 feet)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCable Construction Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eArmored cable with connector protectors (03 Option)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eAgency Approval\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCN (Country-specific hazardous area certifications)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNet Cable Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.29 kg (0.64 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.50 kg (3.30 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-51 to +177 degC (-60 to +350 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUnited States (USA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eConnection Port\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eInterface Type\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eFunctional Assignment \/ Protection\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProbe-End Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eMiniature coaxial male connector\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eMates with the 3300 XL 8mm Probe lead; fitted with a silicone connector protector to seal out fluids.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProximitor-End Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eMiniature coaxial female connector\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eMates with the 3300 XL Proximitor Sensor input; provides critical impedance-matched transition.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis 8.5-meter extension cable is designed to complete a \u003cstrong\u003e9.0-meter total system length\u003c\/strong\u003e when paired with a standard 0.5-meter proximity probe. Coupling this 8.5m cable with a 1.0m probe creates an uncalibrated 9.5m physical system, which will cause severe scale-factor errors in the Proximitor. Always ensure your total length (probe + extension cable) strictly matches the calibration profile of the Proximitor (typically calibrated for 5.0m or 9.0m systems).\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDuring route installation, do not bend the armored conduit beyond its minimum physical dynamic bend radius of 25.4 mm (1.0 inch). Kinking the outer stainless steel armor can deform the inner Teflon-insulated coaxial cable, altering the local characteristic impedance and creating parasitic signal reflections that manifest as false high-frequency vibration spikes on your monitoring instrumentation.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003ePrior to mating the miniature coaxial connections, thoroughly inspect the gold-plated pins for physical misalignment or oil ingress. Use a dedicated contact cleaner if contamination is observed. When tightening the connection, use a finger-tight turn plus a 1\/4 turn with an appropriate connector tool to compress the internal O-ring. Never use pliers directly on the threads as it can strip the micro-coaxial connections.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING: SAFETY COMPLIANCE\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eBefore installing or servicing proximity probe systems in classified hazardous zones, ensure all field loops are electrically de-energized. Safe operation under CN (Country-Specific) certifications requires adherence to national intrinsic safety standards. Failure to isolate power from the Proximitor sensor prior to cable termination can cause electrical sparks capable of igniting explosive atmospheres.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eVerify that the proximity probe and Proximitor sensor are designated for a 9.0-meter system configuration before routing the 8.5-meter extension cable.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eRoute the cable through protected conduit paths, avoiding structural pinch points and heat sources exceeding 177 degC.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eSlide the silicone connector protectors over the connectors and mate the male and female coaxial joints until securely seated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 0.75rem;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eLock the connector protectors in place over the connection seam to establish an IP68-equivalent seal against liquid intrusion.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668306653547,"sku":"330130-085-03-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330130-085-03-CN-sx53jk1htju_932b06ab-d1d3-49d4-8483-c690f2c7d6c3.jpg?v=1765520683","url":"https:\/\/www.plcprotech.com\/de\/products\/bently-nevada-330130-085-03-cn-3300-xl-standard-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}