{"product_id":"bently-nevada-330173-00-02-10-02-00-3300-series-5mm-proximity-probe","title":"Bently Nevada 330173-00-02-10-02-00 3300 Series 5mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered for precise dynamic shaft displacement and vibration measurements, the \u003cstrong\u003eBently Nevada 330173-00-02-10-02-00\u003c\/strong\u003e non-contacting sensor provides critical feedback within machinery protection architectures. Part of the proven \u003cstrong\u003e3300 Series\u003c\/strong\u003e, this 5mm proximity probe operates on eddy current principles to measure static and dynamic distances between the probe tip and the observed conductive target. Built with a polyphenylene sulfide (PPS) tip and an AISI 304 stainless steel case, this configuration features a \u003cstrong\u003e20 mm case length\u003c\/strong\u003e, a \u003cstrong\u003e1.0-meter total cable length\u003c\/strong\u003e, and a miniature coaxial \u003cstrong\u003eClickLoc connector\u003c\/strong\u003e, making it exceptionally reliable in harsh turbine and compressor environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003e5mm Tip Diameter:\u003c\/strong\u003e Ideal for applications with tight physical mounting clearances or smaller target areas.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Durability Materials:\u003c\/strong\u003e Chemically resistant Polyphenylene Sulfide (PPS) tip protects against aggressive lubrication oils and high-temperature environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCorrosion-Resistant Housing:\u003c\/strong\u003e Standard AISI 304 Stainless Steel (SST) threaded body ensures physical integrity over long operational lifespans.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClickLoc Coaxial Connection:\u003c\/strong\u003e Gold-plated miniature coaxial ClickLoc connector provides a secure, vibration-proof link to the extension cable with low resistance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Mounting:\u003c\/strong\u003e Fully unthreaded body (0 mm unthreaded length option) allows for low-profile direct-thread installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eRadial vibration and shaft dynamic alignment monitoring on fluid-film bearing machines.\u003c\/li\u003e\n  \u003cli\u003eAxial thrust position measurement on steam turbines, gas turbines, and industrial compressors.\u003c\/li\u003e\n  \u003cli\u003ePhase reference and speed sensing (Keyphasor) applications on high-speed rotating shafts.\u003c\/li\u003e\n  \u003cli\u003eVibration analysis and diagnostic instrumentation inside tight machinery housings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eValue \/ Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e330173-00-02-10-02-00\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eProbe Diameter\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eUnthreaded Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0 mm (Option 00)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOverall Case Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e20 mm (Option 02)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eTotal Cable Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.0 meter \/ 3.3 feet (Option 10)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eConnector Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eMiniature coaxial ClickLoc connector, standard cable (Option 02)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eAgency Approval Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNot required (Option 00)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eProbe Tip Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eProbe Case Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAISI 304 Stainless Steel (SST)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-51 degC to 177 degC (-60 degF to 350 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eThread Specification\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eM8 x 1 (Standard Metric Thread)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.323 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.3 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e250 x 200 x 50 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUnited States (U.S.A.)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eConnector Pin \/ Part\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eFunction \/ Signal Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eCoaxial Center Conductor\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eHigh-frequency RF signal path \/ DC Bias path (Sensor output returned via Proximitor)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eCoaxial Outer Shield\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSignal Common \/ System return ground\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eConnector Coupling\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eStandard coaxial ClickLoc lock mechanism for low-loss high-frequency connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 330173 series 5mm proximity probe is fully compatible with the 3300 XL 5mm Proximitor Sensor system. Please note that while the physical mounting footprint matches certain standard 8mm probe locations, the 5mm system possesses a distinct calibration curve (typically 7.87 V\/mm or 200 mV\/mil when properly paired with its designated driver). Do not mix 5mm and 8mm components in the same measurement loop as doing so will induce severe scaling errors.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause this specific probe configuration has an overall case length of 20 mm with 0 mm unthreaded length, ensure that your bracket thickness does not exceed the case thread length. Insufficient thread engagement can lead to rotational loosening from machine vibrations. Ensure a minimum radial clearance of at least 15 mm of free area around the probe tip to prevent side-loading calibration drift caused by nearby structural metals.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen routing the 1.0-meter integrated probe cable, avoid sharp bends. Maintain a minimum bend radius of 25.4 mm (1.0 inch) to prevent internal coaxial cable damage. Always use the Bently Nevada recommended ClickLoc connector tool for final mating; do not apply excessive hand force or pliers, which can crush the gold-plated contact pins and introduce signal noise.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e De-energize all machinery and ensure the target shaft is at a complete standstill prior to physical installation. Never adjust probe air gap while the machinery is operating. Failure to do so can result in probe tip contact with the rotating shaft, causing catastrophic machine damage and severe physical injury.\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eEnsure the mounting hole is clean, dry, and tapped straight to standard metric M8 x 1 dimensions. Verify that there are no metal filings remaining in the thread path.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eThread the probe into the mounting bracket or machine casing by hand. Gently rotate until the probe tip makes light contact with the target calibration plate or shaft surface.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eConnect a calibrated digital multimeter to the corresponding Proximitor Sensor output. Back the probe out until the DC voltage matches your desired calibration center point (typically -10.0 VDC for standard scale mid-range).\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eSecure the outer locking nut to the recommended torque specifications, ensuring the probe body does not rotate during final tightening. Apply self-fusing silicone tape to protect the ClickLoc connector joint from moisture and oil mist.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668302197099,"sku":"330173-00-02-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330173-00-02-10-02-00-new-4yg2arggnvv_77120c8c-633f-4cb5-8806-a6cab98bdc80.jpg?v=1765520575","url":"https:\/\/www.plcprotech.com\/de\/products\/bently-nevada-330173-00-02-10-02-00-3300-series-5mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}