{"product_id":"bently-nevada-330701-00-20-10-02-00-3300-xl-11-mm-proximity-probe","title":"Bently Nevada 330701-00-20-10-02-00 3300 XL 11 mm Näherungssonde","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eFully threaded 1\/2-20 UNF steel probe body (Option 00) with a 2.0 in case length (Option 20) and 1.0 m total length (Option 10) — \u003cstrong\u003e330701-00-20-10-02-00\u003c\/strong\u003e is an eddy-current non-contact \u003cstrong\u003e3300 XL 11 mm proximity probe\u003c\/strong\u003e configuration. This assembly operates within a 3300 XL 11 mm transducer system to measure shaft vibration, axial position, and rotor movement on rotating machinery. Featuring standard triaxial cable and a ClickLoc miniature coaxial connector without a connector protector (Option 02), this configuration is suited for installations where hazardous area agency approvals are not required (Option 00).\u003c\/p\u003e\n\n\u003cp\u003eCompared to alternative configurations such as the 330702 probe which includes stainless steel armor, or alternative segments that feature integrated fluorosilicone connector protectors, this non-armored probe is used in clean environments with standard conduit routing. The 1.0 m total length option pairs with standard 3300 XL 4.0 m extension cables to form a complete 5.0 m system, matching the calibration of a standard 3300 XL 11 mm Proximitor Sensor.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread configuration:\u003c\/strong\u003e 1\/2-20 UNF-2A thread configuration with 0.0 in unthreaded length (fully threaded case) and 2.0 in overall case length.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhysical protection:\u003c\/strong\u003e Standard triaxial cable construction without external stainless steel armor, facilitating routing through standard protective conduit.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection type:\u003c\/strong\u003e Gold-plated miniature ClickLoc coaxial connector provides solid electrical termination to the extension cable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard length:\u003c\/strong\u003e 1.0 meter (3.3 feet) overall length, designed for integration into 5.0-meter transducer system configurations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGeneral area version:\u003c\/strong\u003e Option 00 configuration is selected for industrial applications where hazardous area certifications are not required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and axial position measurements on rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eRotor movement and thermal expansion monitoring in industrial steam turbines and gas turbines.\u003c\/li\u003e\n  \u003cli\u003eFluid-film bearing clearance measurements in centrifugal compressors, generators, and large pumps.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection monitoring in industrial facilities, power generation plants, and water treatment utilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330701-00-20-10-02-00\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Probe, 1\/2-20 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20\u003c\/td\u003e\n      \u003ctd\u003e2.0 in (threaded length configuration)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330701-00-20-10-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.0 mm (160 mils), beginning at 0.5 mm (20 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.5 mm (100 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.94 V\/mm (100 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 8 kHz: +0, -3 dB typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Specification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1\/2-20 UNF-2A thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.0 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Probe Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector (gold-plated brass)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, FEP insulated, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Case Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45.2 N-m (400 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Case Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15.2 N-m (133 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePressure Sealing\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDifferential pressure sealing via Viton O-ring between probe tip and case\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount in a threaded bracket or machine housing. Tighten the 1\/2-20 UNF thread with a torque wrench to the recommended 15.2 N-m (133 in-lb). Do not exceed the maximum rated torque of 45.2 N-m (400 in-lb) to avoid casing deformation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable routing:\u003c\/strong\u003e Maintain a minimum cable bend radius of 25.4 mm (1.0 in) to prevent damage to the FEP-insulated triaxial construction. Route the standard non-armored cable through protective conduit to shield from physical damage, abrasive wear, and mechanical stress.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector connection:\u003c\/strong\u003e Join the miniature male ClickLoc connector on the probe cable to the female ClickLoc connector of the extension cable. Hand-tighten until snug. To prevent oil and moisture intrusion, install a connector protector or wrap with self-fusing silicone tape if exposed to fluids.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe gap:\u003c\/strong\u003e Set the probe-to-target gap using a physical feeler gauge or by measuring the DC output voltage of the Proximitor Sensor. The typical recommended gap of 2.5 mm (100 mils) corresponds to a DC voltage of approximately -10 Vdc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility:\u003c\/strong\u003e Complies with European Union EMC Directive 2014\/30\/EU, meeting standard requirements EN 61000-6-2 (Immunity for Industrial Environments) and EN 61000-6-4 (Emissions for Industrial Environments).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e Complies with European Union RoHS Directive 2011\/65\/EU.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFCC Part 15:\u003c\/strong\u003e Complies with United States FCC Part 15 requirements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666632372587,"sku":"330701-00-20-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330701-00-20-10-02-00-3300-xl-11-mm-proximity-transducer-nhhzvitgpbn_700d76da-ff48-4301-b59a-ba347a3a5f10.jpg?v=1765444414","url":"https:\/\/www.plcprotech.com\/de\/products\/bently-nevada-330701-00-20-10-02-00-3300-xl-11-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}