{"product_id":"bently-nevada-330703-000-040-50-11-00-3300-xl-11-mm-proximity-probe","title":"Bently Nevada 330703-000-040-50-11-00 3300 XL 11 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eUnarmored M14 x 1.5 threaded probe body (Option 000) with a 40 mm case length (Option 040) and a 5.0 m total cable length (Option 50) specifies the \u003cstrong\u003e330703-000-040-50-11-00\u003c\/strong\u003e \u003cstrong\u003e3300 XL 11 mm Proximity Probe\u003c\/strong\u003e. This non-contacting eddy-current sensor is utilized within 3300 XL 11 mm monitoring chains to measure shaft displacement, dynamic vibration, or static axial position relative to fluid film bearings.\u003c\/p\u003e\n\n\u003cp\u003eThis metric-threaded configuration differs from common imperial-threaded models (such as the 330701 series) and armored variations (such as the 330704 series) by featuring a bare, unarmored FEP-insulated coaxial cable. Equipped with Option 11, it incorporates a specialized FluidLoc cable to block process fluid leakage migration along the internal conductor spacing, paired with an integrated coaxial connector protector designed for wet or high-humidity installations. The 5.0 m total system length matches the electrical calibration requirements of a 5.0 m Proximitor Sensor, allowing direct termination without an intermediary extension cable.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMetric M14 x 1.5 threaded steel probe body without external protective armor\u003c\/li\u003e\n  \u003cli\u003eOption 000 fully threaded design providing 0 mm unthreaded length\u003c\/li\u003e\n  \u003cli\u003eOption 040 providing 40 mm total case length for shallow thread engagement\u003c\/li\u003e\n  \u003cli\u003eOption 50 providing a 5.0 m (16.4 feet) integrated triaxial cable length\u003c\/li\u003e\n  \u003cli\u003eOption 11 FluidLoc cable style to prevent oil and fluid migration through the cable interior\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass ClickLoc coaxial connector with pre-installed fluorosilicone connector protector\u003c\/li\u003e\n  \u003cli\u003eCalibrated for standard AISI 4140 steel target surfaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAxial (thrust) position measurements on large steam and gas turbines\u003c\/li\u003e\n  \u003cli\u003eRamp differential expansion measurements on industrial power generation turbines\u003c\/li\u003e\n  \u003cli\u003eRod position or rod drop monitoring on reciprocating compressors\u003c\/li\u003e\n  \u003cli\u003eRadial vibration and shaft positioning on heavy rotating machinery\u003c\/li\u003e\n  \u003cli\u003eKeyphasor phase reference and zero-speed tachometer signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment Position\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning \/ Configuration Detail\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330703-000-040-50-11-00\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Probe, M14 x 1.5 metric thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAAA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e000\u003c\/td\u003e\n      \u003ctd\u003e0 mm unthreaded length (fully threaded)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBBB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e040\u003c\/td\u003e\n      \u003ctd\u003e40 mm overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDD - Connector \u0026amp; Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector, FluidLoc cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eApprovals not required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter Group\u003c\/th\u003e\n      \u003cth\u003eSpecification \/ Metric Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330703 (M14 x 1.5 Thread, Unarmored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Construction\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, FEP insulated, FluidLoc style\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc miniature coaxial (male)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Protector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFluorosilicone material (pre-installed on cable end)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.0 mm (160 mils), beginning at approximately 0.5 mm (20 mils) from the target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApproximately -1 to -17 Vdc over linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.94 V\/mm (100 mV\/mil) +\/-10% (measured in 0.5 mm increments)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Frequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 8 kHz: +0, -3 dB typical (with up to 305 meters of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.5 mm (100 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe dc Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.2 +\/-0.8 ohms (center to outer conductor for 5.0 m probe)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePressure Seal Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring sealed (exposure below -34 degC \/ -30 degF can affect seal integrity)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Installation Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e63.3 N-m (560 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Installation Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e21.1 N-m (187 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Thread Engagement Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e21 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Cable Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Tensile Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lb) probe case to probe lead connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePosition the probe to the nominal gap of 2.5 mm (100 mils) from the target surface, corresponding to the electrical midpoint of the linear range.\u003c\/li\u003e\n  \u003cli\u003eTighten the M14 x 1.5 thread body utilizing the integrated wrench flats. Torque to the recommended 21.1 N-m (187 in-lb) and do not exceed the maximum limit of 63.3 N-m (560 in-lb).\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum cable routing bend radius of 25.4 mm (1.0 in) to prevent internal coaxial conductor degradation.\u003c\/li\u003e\n  \u003cli\u003eAvoid installing with thread engagement lengths exceeding 21 mm to prevent binding during mounting.\u003c\/li\u003e\n  \u003cli\u003eEnsure the pre-installed connector protector is fully seated and dry before completing the coaxial interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eElectromagnetic Compatibility (EMC): European Community Directive 2014\/30\/EU\u003c\/li\u003e\n  \u003cli\u003eEMC Standards: EN 61000-6-2 (Immunity), EN 61000-6-4 (Emissions)\u003c\/li\u003e\n  \u003cli\u003eRestriction of Hazardous Substances (RoHS): European Community Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003eDamp Heat Resistance: Tested in accordance with IEC 68-2-3 standards\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666555629931,"sku":"330703-000-040-50-11-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330703-000-040-50-11-00-proximity-probes-aufawor4ajv_75b1dfbe-4abf-457d-af36-1c5ae2d78f02.jpg?v=1765440617","url":"https:\/\/www.plcprotech.com\/de\/products\/bently-nevada-330703-000-040-50-11-00-3300-xl-11-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}