{"product_id":"bently-nevada-330854-080-24-00-3300-xl-25-mm-extension-cable","title":"Bently Nevada 330854-080-24-00 3300 XL 25 mm Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 080 (8.0 m length), Option 24 (High Temperature FluidLoc cable, unarmored), and Option 00 (no agency approvals) specify this \u003cstrong\u003e3300 XL 25 mm Extension Cable\u003c\/strong\u003e configuration — \u003cstrong\u003e330854-080-24-00\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis cable acts as the electrical link between a 3300 XL 25 mm proximity probe and a 3300 XL 25 mm Proximitor sensor. Unlike variant option 25 which features stainless steel armor, this option 24 configuration uses a lightweight, unarmored 75 ohm triaxial FluidLoc cable insulated with perfluoroalkoxyethylene (PFA). The FluidLoc technology prevents moisture and process fluids from traversing the cable core, protecting the click-lock coaxial connectors from contamination.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8.0 meter total length (Option 080) matches system calibration when combined with a 1.0 meter probe in a 9.0 meter measurement system.\u003c\/li\u003e\n  \u003cli\u003eOption 24 configuration features non-armored 75 ohm triaxial FluidLoc cable insulated with perfluoroalkoxyethylene (PFA) for high-temperature service.\u003c\/li\u003e\n  \u003cli\u003eFluidLoc cable design blocks fluid migration through the internal conductors of the cable assembly.\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass and beryllium copper ClickLoc connectors provide stable coaxial contact under mechanical vibration.\u003c\/li\u003e\n  \u003cli\u003eOption 00 indicates standard commercial construction with no hazardous area approvals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLarge steam turbine generator differential expansion (DE) monitoring\u003c\/li\u003e\n  \u003cli\u003eMid-to-large machinery axial shaft position measurements\u003c\/li\u003e\n  \u003cli\u003eReciprocating compressor rod-drop monitoring systems\u003c\/li\u003e\n  \u003cli\u003eHydroelectric turbine shaft displacement and vibration sensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330854-080-24-00\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 25 mm Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Cable Length\u003c\/td\u003e\n      \u003ctd\u003e080\u003c\/td\u003e\n      \u003ctd\u003e8.0 metres (26.2 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Armor and Cable\u003c\/td\u003e\n      \u003ctd\u003e24\u003c\/td\u003e\n      \u003ctd\u003eHigh Temperature FluidLoc cable (no armor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Agency Approval\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330854-080-24-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, perfluoroalkoxyethylene (PFA) insulated FluidLoc cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.0 metres (26.2 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCore Resistance (Rcore)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 +\/- 0.5 ohms (Center conductor to center conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eJacket\/Coaxial Resistance (Rjacket)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.6 +\/- 0.2 ohms (Coaxial conductor to coaxial conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass and gold-plated beryllium copper ClickLoc connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e270 N (60 pounds) maximum rated at probe lead to extension cable connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTorque Specification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRecommended finger tight; maximum 0.565 N-m (5 in-lb) connector-to-connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-35 degC to +200 degC (-31 degF to +392 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHumidity Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 g\/m (approx. 360 g for 8.0 m cable length)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Side\u003c\/th\u003e\n      \u003cth\u003eConnector Type\u003c\/th\u003e\n      \u003cth\u003eCompatibility\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Connection\u003c\/td\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc connector\u003c\/td\u003e\n      \u003ctd\u003eConnects to 3300 XL 25 mm proximity probe female connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProximitor Connection\u003c\/td\u003e\n      \u003ctd\u003eMiniature female coaxial ClickLoc connector\u003c\/td\u003e\n      \u003ctd\u003eConnects to 3300 XL 25 mm Proximitor sensor male connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCoaxial shielding is isolated from the mounting bracket or panel and must be grounded at the monitor\/instrumentation rack.\u003c\/li\u003e\n  \u003cli\u003eEnsure the fluorosilicone connector protectors are installed over the mated ClickLoc connectors to prevent contamination from dirt and moisture.\u003c\/li\u003e\n  \u003cli\u003eMaintain the minimum bend radius of 25.4 mm (1.0 inch) during routing to prevent cable strain or internal signal degradation. Avoid running the extension cable alongside high-voltage AC power wiring to prevent electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003eHand-tighten the ClickLoc connectors; do not exceed 0.565 N-m (5 in-lb) of torque.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Mark (European Conformity)\u003c\/li\u003e\n  \u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847560043,"sku":"330854-080-24-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330854-080-24-00-extension-cable-z2nzqpsxarh_efb38a8e-1b8f-40c5-aa16-fe3daefe16ae.jpg?v=1765448964","url":"https:\/\/www.plcprotech.com\/de\/products\/bently-nevada-330854-080-24-00-3300-xl-25-mm-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}