{"product_id":"bently-nevada-330881-28-04-110-06-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-04-110-06-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eNon-contact eddy-current displacement probe and sensor assembly for 3300 XL monitoring systems; orderable configuration \u003cstrong\u003e330881-28-04-110-06-02\u003c\/strong\u003e integrates a 3300 XL 8 mm probe with Multiple Approvals (Option 28) and a Proximitor sensor inside a single environmental housing. By using a 40 mm standoff adapter (Option 04) and a 110 mm probe penetration (Option 110), this metric PROXPAC XL assembly mounts directly to rotating machinery cases to measure shaft vibration, radial position, or axial position.\u003c\/p\u003e\n\n\u003cp\u003eCompared to standard 3300 XL separate probe and sensor systems, this integrated transducer assembly eliminates the need for an external extension cable and separate Proximitor housing. The glass-reinforced polyphenylene sulfide (PPS) thermoplastic housing of this metric assembly is rated IP66\/Type 4X, providing protective isolation in harsh environments. It features Option 06 fittings, consisting of one 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1 1\/2-14 NPT stainless steel reducer, and two plugs, paired with a 3\/4-14 NPT mounting thread (Option 02).\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 28 probe configuration provides a 3300 XL 8 mm proximity probe with multiple hazardous area approvals, installed directly in the sleeve.\u003c\/li\u003e\n  \u003cli\u003eOption 04 standoff adapter specifies a 40 mm standoff length (orderable in increments of 10 mm).\u003c\/li\u003e\n  \u003cli\u003eOption 110 probe penetration establishes a 110 mm penetration depth (orderable in increments of 1 mm).\u003c\/li\u003e\n  \u003cli\u003eOption 06 fittings package supplies one 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1 1\/2-14 NPT stainless steel reducer, and two plugs.\u003c\/li\u003e\n  \u003cli\u003eOption 02 mounting thread specifies a 3\/4-14 NPT connection, required for standoff adapter mounting.\u003c\/li\u003e\n  \u003cli\u003eThermoplastic housing constructed of glass-reinforced polyphenylene sulfide (PPS) with conductive fibers to dissipate electrostatic charges.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Proximitor sensor design eliminates the need for an extension cable and separate sensor housing, allowing direct field wiring to monitors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial shaft vibration and axial position measurements in rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eMachinery monitoring and protection where integrated transducers reduce wiring complexity.\u003c\/li\u003e\n  \u003cli\u003ePetrochemical, power generation, and gas turbine applications with strict environmental sealing requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330881-28-04-110-06-02\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Probe and Approvals Option\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Standoff Adapter Option (B Dimension)\u003c\/td\u003e\n      \u003ctd\u003e04\u003c\/td\u003e\n      \u003ctd\u003e40 mm standoff adapter length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Probe Penetration Option (C Dimension)\u003c\/td\u003e\n      \u003ctd\u003e110\u003c\/td\u003e\n      \u003ctd\u003e110 mm probe penetration depth\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Fittings Option\u003c\/td\u003e\n      \u003ctd\u003e06\u003c\/td\u003e\n      \u003ctd\u003eOne 3\/4-14 NPT fitting, one 3\/4-14 NPT to 1 1\/2-14 NPT stainless steel reducer, and two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Mounting Thread Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT (required when ordering standoff adapter)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-28-04-110-06-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer Assembly\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProximitor Sensor Input\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe with 1-metre cable length installed in the probe sleeve\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRequires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum consumption; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils), starting approximately 0.25 mm (10 mils) from target to 2.3 mm (90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% including interchangeability error (0 degC to +45 degC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB, with up to 305 metres (1000 feet) of field wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter flat target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Sleeve and Retaining Screws\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Pressure Seal\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSealed against differential pressure with a Viton O-ring inside the probe case\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP66 and Type 4X rating\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Housing \u0026amp; Sensor)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cp\u003eField wiring terminals are located inside the housing lid on the Proximitor sensor module. Field wiring should use 3-conductor twisted, shielded cable (18 AWG \/ 1.0 sq mm recommended) to connect the PROXPAC XL directly to the monitoring system.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the grounding liner and retaining plate are properly installed inside the plastic housing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConduit Protection:\u003c\/strong\u003e Use conduit fittings when hardline conduit or metal piping is brought into the housing. If using flexible conduit, order with integral fittings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Field wiring should use 3-conductor shielded twisted-pair cable (16 to 24 AWG) with drain wire, grounded at the monitor end only.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSleeve Support:\u003c\/strong\u003e If combined standoff adapter and probe penetration lengths exceed 305 mm, additional sleeve support must be provided near the probe to avoid resonance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Torque:\u003c\/strong\u003e Tighten retaining nut to 29.5 N-m (260 in-lb) and probe sleeve locknut to 39.3 N-m (350 in-lb).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666755645803,"sku":"330881-28-04-110-06-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-04-110-06-02-proxpac-xl-proximity-transducer-nsahwprdqed_cbc4cd02-e116-4f53-9bac-88cca2fbf6a2.jpg?v=1765447037","url":"https:\/\/www.plcprotech.com\/de\/products\/bently-nevada-330881-28-04-110-06-02-proxpac-xl-proximity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}