{"product_id":"bently-nevada-330901-00-45-10-02-00-3300-nsv-proximity-probe","title":"Bently Nevada 330901-00-45-10-02-00 3300 NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eFully threaded 1\/4-28 UNF steel probe body (Option 00 unthreaded length) with a 4.5-inch case length (Option 45) and a 1.0-meter total length (Option 10) specifies this \u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e configuration — \u003cstrong\u003e330901-00-45-10-02-00\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThis configuration operates as part of the 3300 XL NSv Proximity Transducer System, which is used for non-contact displacement measurements in machinery with tight installation limits. This specific unarmored variant features a standard coaxial cable equipped with a miniature coaxial ClickLoc connector (Option 02) and requires no special agency approvals (Option 00). It is designed to withstand harsh process environments, offering increased chemical resistance and superior side-view characteristics compared to older legacy transducer systems.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThread size of 1\/4-28 UNF-2A without protective stainless steel armor for direct thread mounting.\u003c\/li\u003e\n  \u003cli\u003eUnthreaded length of 0.0 inches (Option 00) for fully threaded case installations.\u003c\/li\u003e\n  \u003cli\u003eOverall case length of 4.5 inches (Option 45) designed for deep mechanical mounting.\u003c\/li\u003e\n  \u003cli\u003eTotal length of 1.0 meter (Option 10) standard cable designed to connect directly with a 3300 XL NSv extension cable and Proximitor sensor.\u003c\/li\u003e\n  \u003cli\u003eClickLoc miniature coaxial connector (Option 02) providing secure mechanical locking and preventing connection loosening.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) probe tip and AISI 304 stainless steel probe case materials for increased durability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration, radial position, and axial position monitoring on fluid-filmed bearing machines.\u003c\/li\u003e\n  \u003cli\u003eHeavy-duty machinery such as centrifugal air compressors, refrigeration compressors, and process gas compressors.\u003c\/li\u003e\n  \u003cli\u003eSmall-bore machinery and small target applications, including shafts smaller than 51 mm (2.0 in) or flat targets smaller than 15 mm (0.6 in).\u003c\/li\u003e\n  \u003cli\u003eLow-clearance or tight installation constraints such as narrow counterbores or limited side-view clearances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning from Datasheet\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330901-00-45-10-02-00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe, 1\/4-28 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm) unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n      \u003ctd\u003e45\u003c\/td\u003e\n      \u003ctd\u003e4.5 in (114 mm) overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (39 in) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector and Cable-Type Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNot required (no approvals)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330901-00-45-10-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTransducer System Series\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThread Type\u003c\/td\u003e\n      \u003ctd\u003e1\/4-28 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eArmor Option\u003c\/td\u003e\n      \u003ctd\u003eWithout armor (unarmored standard cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Cable Type\u003c\/td\u003e\n      \u003ctd\u003e75 ohm coaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils), beginning at approx. 0.25 mm (10 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n      \u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% (including interchangeability error)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils) over linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Requirements\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc at 12 mA maximum consumption (at Proximitor sensor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe dc Resistance (RPROBE)\u003c\/td\u003e\n      \u003ctd\u003e4.2 ohms +\/- 0.5 ohms (center conductor to shield)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Tensile Strength\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) probe case to lead connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity Limits\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Torque\u003c\/td\u003e\n      \u003ctd\u003e5.1 N m (45 in lb) (Maximum rated: 7.3 N m \/ 65 in lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMaintain minimum case-to-case clearance and use a recommended counterbore diameter of 13 mm (0.5 in) to avoid sideview interference with surrounding metal.\u003c\/li\u003e\n  \u003cli\u003eEnsure a Class 2B fit class for external-to-internal thread matching on the 1\/4-28 UNF threads.\u003c\/li\u003e\n  \u003cli\u003eA #3 or larger tap drill size is recommended when drilling and tapping mounting holes for this probe.\u003c\/li\u003e\n  \u003cli\u003eFinger-tighten the miniature coaxial ClickLoc connector by hand, and do not exceed the maximum torque rating of 0.56 N m (5 in lb).\u003c\/li\u003e\n  \u003cli\u003eProtect the probe-to-extension cable connections using connector protectors or silicone tape to prevent moisture and chemical ingress.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666543079787,"sku":"330901-00-45-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330901-00-45-10-02-00-3300-nsv-proximity-probes-3g33pvnyvav_1fa1abd4-de03-434c-af38-6f5fa52cfd29.jpg?v=1765440490","url":"https:\/\/www.plcprotech.com\/de\/products\/bently-nevada-330901-00-45-10-02-00-3300-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}