{"product_id":"bently-nevada-330901-14-43-05-02-05-3300-nsv-proximity-probe","title":"Bently Nevada 330901-14-43-05-02-05 3300 NSv Näherungssensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 14 (1.4 in unthreaded length) and Option 43 (4.3 in overall case length) specify this particular 3300 NSv proximity probe configuration — \u003cstrong\u003e330901-14-43-05-02-05\u003c\/strong\u003e. Used for non-contact shaft displacement measurements in tight clearances, this eddy-current sensor features a 1\/4-28 UNF thread without armor and a 0.5 m (20 in) coaxial cable terminated in a miniature ClickLoc connector. It is designed specifically for small-bore machinery, high-speed gearboxes, and aeroderivative turbines with restricted target sizes or side-view clearances.\u003c\/p\u003e\n\u003cp\u003eUnlike variants equipped with stainless steel armor (such as the 330902 series) or FluidLoc chemical-sealing cables, this unarmored configuration offers maximum flexibility in clean conduits and tight mounting bores. The standard coaxial cable with a gold-plated miniature ClickLoc connector prevents connector loosening in environments prone to mild vibration without the bulk of an added connector protector (Option 02). This configuration is certified for hazardous areas under the Multiple Approvals option (Option 05).\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1\/4-28 UNF Thread\u003c\/strong\u003e: Unarmored threaded probe body (Base Model 330901) for standard imperial mounting taps.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e: 1.4 inches (Option 14) unthreaded body portion for specific recessed bracket setups.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCase Length\u003c\/strong\u003e: 4.3 inches (Option 43) overall case length.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTotal Length\u003c\/strong\u003e: 0.5 meter (Option 05) total system length, allowing short lead connection to the extension cable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClickLoc Connector\u003c\/strong\u003e: Gold-plated miniature brass ClickLoc coaxial connector (Option 02) without a silicone connector protector.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e: Multiple Approvals package (Option 05) certified for intrinsically safe installations in hazardous areas.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e: Operates with the 3300 XL NSv Proximitor Sensor (330980) and 330930 extension cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and shaft position measurements on narrow shafts smaller than 51 mm (2 in).\u003c\/li\u003e\n  \u003cli\u003eAxial (thrust) position measurements on flat targets smaller than 15 mm (0.6 in).\u003c\/li\u003e\n  \u003cli\u003eCentrifugal refrigeration compressors and process gas compressors with limited installation clearance.\u003c\/li\u003e\n  \u003cli\u003eHigh-speed turbomachinery and aeroderivative gas turbines.\u003c\/li\u003e\n  \u003cli\u003eTachometer, speed, and Phase Reference (Keyphasor) signal generation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning \/ Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBase Model Number\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330901\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe, 1\/4-28 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e14\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.4 in (36 mm) unthreaded length (increments of 0.1 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e43\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.3 in (109 mm) overall case length (increments of 0.1 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 meter (20 in) total probe cable length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector \u0026amp; Cable Option\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMultiple approvals (CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number \/ Model\u003c\/td\u003e\n      \u003ctd\u003e330901-14-43-05-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Thread\u003c\/td\u003e\n      \u003ctd\u003e1\/4-28 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnarmored Design\u003c\/td\u003e\n      \u003ctd\u003eYes (unarmored coaxial cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Measurement Range\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils), from approximately 0.25 to 1.75 mm (10 to 70 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% (including interchangeability error)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils) over linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n      \u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB typical with up to 305 meters (1000 feet) field wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Target Diameter (Shaft)\u003c\/td\u003e\n      \u003ctd\u003e8.9 mm (0.35 in) standard, 13 mm (0.5 in) recommended minimum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Power Range\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (no safety barriers at 12 mA max); -23 Vdc to -26 Vdc (with barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe DC Resistance (RPROBE)\u003c\/td\u003e\n      \u003ctd\u003e4.0 +\/-0.5 ohms (center conductor to outer shield)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating \/ Storage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSealing Material\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring pressure seal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Pull Strength\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) probe case to probe lead (CableLoc design)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Material\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc coaxial\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Limits\u003c\/strong\u003e: Do not exceed the maximum rated installation torque of 5.1 N-m (45 in-lb) for 1\/4-28 UNF probe cases.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e: Maintain a minimum cable bend radius of 25.4 mm (1.0 in) for coaxial routing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCross-Talk Prevention\u003c\/strong\u003e: When installing multiple radial or X-Y probe pairs, keep probe tips separated by at least 23 mm (0.9 in).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Engagement\u003c\/strong\u003e: Avoid binding by limiting thread engagement to a maximum of 1.5 times the nominal thread diameter.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eField Wiring\u003c\/strong\u003e: Use three-conductor shielded triad field wiring (0.2 to 1.5 mm2 or 16 to 24 AWG) to connect the Proximitor Sensor to the monitor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Areas (Option 05)\u003c\/strong\u003e: Class I, Zone 0, AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III (intrinsically safe when barrier protected).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety\u003c\/strong\u003e: SIL 2 (HFT=0) and SIL 3 (HFT=1) certified in accordance with IEC 61508.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility\u003c\/strong\u003e: Complies with EMC Directive 2014\/30\/EU, EN 61000-6-2 (Immunity), and EN 61000-6-4 (Emissions).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e: Complies with RoHS Directive 2011\/65\/EU and China RoHS (15-year Environment-Friendly Use Period).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666848117099,"sku":"330901-14-43-05-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330901-14-43-05-02-05-3300-nsv-proximity-probes-bqmaxsyi13i_ab3b2dfa-806e-4d7c-b180-d7c5a5665286.jpg?v=1765448974","url":"https:\/\/www.plcprotech.com\/de\/products\/bently-nevada-330901-14-43-05-02-05-3300-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}