{"product_id":"bently-nevada-330910-14-19-10-02-00-3300-nsv-proximity-probe","title":"Bently Nevada 330910-14-19-10-02-00 3300 NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330910-14-19-10-02-00\u003c\/strong\u003e is an eddy-current \u003cstrong\u003e3300 NSv Proximity Probe\u003c\/strong\u003e engineered by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e for industrial machinery vibration monitoring and asset protection. This small-profile transducer operates as part of the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e, which is specifically optimized for centrifugal air compressors, refrigeration compressors, and process gas machinery with restrictive installation geometries. It functions by generating a high-frequency radio frequency (RF) field from its tip, detecting micro-gap variations caused by eddy currents on a moving target face, and transmitting raw displacement signals back to a conditioning Proximitor sensor.\u003c\/p\u003e\n\u003cp\u003eThis non-contacting sensor is ideal for applications where counterbore, sideview, or rearview limitations restrict the use of standard 5 mm or 8 mm probe systems. The \u003cstrong\u003e330910-14-19-10-02-00\u003c\/strong\u003e features an M10X1 metric thread chassis equipped with a stainless steel interlocking armor sleeve to safeguard the extension wire against mechanical stress and fluid friction. It is calibrated to measure radial shaft vibration on small shaft diameters (under 51 mm or 2 in) or axial thrust position on flat targets smaller than 15 mm (0.6 in). Operating without external agency certifications under this general-purpose designation, the probe delivers a continuous linear displacement signal to host diagnostic platforms.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSpecialized small-profile design engineered for tight counterbores and restricted sideview clearance zones.\u003c\/li\u003e\n\u003cli\u003eM10X1 metric threaded case construction paired with stainless steel interlocking armor for high durability.\u003c\/li\u003e\n\u003cli\u003eGold-plated brass ClickLoc coaxial connector ensuring a positive, vibration-resistant locking terminal interface.\u003c\/li\u003e\n\u003cli\u003eOptimized core electronics capable of tracking small targets, including narrow shaft profiles under 51 mm.\u003c\/li\u003e\n\u003cli\u003eFull backward compatibility with legacy Bently Nevada 3300 RAM transducer loops and 190 series systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial vibration and dynamic shaft position monitoring on fluid-film bearings of high-speed centrifugal air compressors.\u003c\/li\u003e\n\u003cli\u003eRotor axial thrust displacement measurement inside small-envelope industrial turbo-expanders.\u003c\/li\u003e\n\u003cli\u003eHigh-frequency tachometer, shaft speed sensing, and Keyphasor phase reference signal acquisition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Profile \u0026amp; Exact Weight Formulas\u003c\/h3\u003e\n\u003cp\u003eIn high-precision reliability engineering, using default box sizes or generic dimensions creates severe alignment risks. According to the official Bently Nevada 147385 datasheet parameters, the true mechanical configuration, physical footprint, and cumulative mass metrics for this specific 1.0-meter armored assembly are calculated as follows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnthreaded Case Length (Option A):\u003c\/strong\u003e Exactly \u003cstrong\u003e14 mm\u003c\/strong\u003e (0.55 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Case Length (Option B):\u003c\/strong\u003e Exactly \u003cstrong\u003e19 mm\u003c\/strong\u003e (0.75 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThreaded Case Section:\u003c\/strong\u003e Calculated as Overall Case Length minus Unthreaded Length (19 mm - 14 mm) = \u003cstrong\u003e5 mm\u003c\/strong\u003e (0.20 in) of active M10X1 threads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Physical Cable Length (Option C):\u003c\/strong\u003e Exactly \u003cstrong\u003e1.0 meter\u003c\/strong\u003e (3.9 feet \/ 39 inches) from probe tip to the end of the coaxial terminal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Mass Density of Armored Cable:\u003c\/strong\u003e Nominal \u003cstrong\u003e64 grams per meter\u003c\/strong\u003e (0.70 oz\/foot) due to the heavy-duty interlocking stainless steel protective outer armor sleeve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Probe Head and Brass Hardware Mass:\u003c\/strong\u003e Approximately \u003cstrong\u003e30 grams\u003c\/strong\u003e (1.06 oz) including the M10 case, coil assembly, and rear transition hub.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Net Hardware Weight:\u003c\/strong\u003e Calculated as (64 g\/m x 1.0 m) + 30 g = \u003cstrong\u003e94 grams\u003c\/strong\u003e (3.32 oz) absolute dry weight per assembly (excluding shipping container and the included 17 mm lock nut).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code Slot\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelected Option Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330910\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Probe, M10X1 thread, with armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Unthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-14\u003c\/td\u003e\n\u003ctd\u003e14 mm unthreaded section length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Overall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-19\u003c\/td\u003e\n\u003ctd\u003e19 mm total barrel case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (39 in) physical cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Connector\/Cable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-02\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE: Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-00\u003c\/td\u003e\n\u003ctd\u003eNot required (General purpose \/ unclassified area rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePrecise Engineering Data\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330910-14-19-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-contacting Eddy-Current Proximity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM10 X 1 metric configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils) nominal tracking window\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) when matched with NSv Proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Nominal Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Probe Cable Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 g\/m (0.5 oz\/ft) nominal line weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Protection Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterlocking stainless steel armor wrap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Metallurgy Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass body matching ClickLoc infrastructure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Case Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in) absolute field constraint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Element\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThreaded M10X1 Barrel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect physical installation interface into machine housing walls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClickLoc Miniature Plug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMale coaxial terminal linking into the 3300 NSv extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal System Loop Matching:\u003c\/strong\u003e This 1.0-meter physical length probe \u003cstrong\u003emust\u003c\/strong\u003e be paired with a 4.0-meter extension cable to form a 5.0-meter total system loop, or a 6.0-meter extension cable to form a 7.0-meter total system loop. The total length must precisely match the electrical calibration length of the 3300 XL NSv Proximitor sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Gap Adjustment:\u003c\/strong\u003e Manually thread the probe into the machine casing until the tip contacts the target surface, then back it out to the designated linear gap voltage threshold (typically -9.0 Vdc or central linear range) before tightening the 17 mm lock nut.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvoid Ground Contacts:\u003c\/strong\u003e Ensure the miniature coaxial ClickLoc connector junction does not touch the metal walls of the junction box or conduit fittings. Wrap the connected union with self-fusing silicone tape to prevent electrical noise loop interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Protection Routing:\u003c\/strong\u003e The flexible stainless steel armor provides mechanical deflection protection; however, the probe lead wire should still be routed within dedicated low-voltage instrument trays to minimize exposure to high-voltage electromagnetic fields (EMI).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666517619051,"sku":"330910-14-19-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330910-14-19-10-02-00-3300-xl-nsv-proximity-probe-dgegdyqjksn_55faa2d1-62d4-4063-99d7-51ad00977067.jpg?v=1765440106","url":"https:\/\/www.plcprotech.com\/de\/products\/bently-nevada-330910-14-19-10-02-00-3300-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}