{"product_id":"bently-nevada-3500-05-02-04-00-00-01-3500-series-system-rack","title":"Bently Nevada 3500\/05-02-04-00-00-01 3500 Series System Rack","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned to serve as the structural and communication backbone for machinery protection systems, the \u003cstrong\u003eBently Nevada 3500\/05-02-04-00-00-01\u003c\/strong\u003e is a specialized 12-inch Mini-Rack chassis engineered to house and interconnect Bently Nevada 3500 series modules. This rack features \u003cstrong\u003e7 available module slots\u003c\/strong\u003e to consolidate vibration monitoring, keyphasor signals, and relay outputs into a compact footprint. It incorporates a high-integrity backplane that facilitates continuous power distribution and high-speed digital data transfer between installed monitoring modules and transient data interfaces, ensuring uninterrupted mechanical diagnostic capabilities for heavy industrial machinery.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Form Factor:\u003c\/strong\u003e 12-inch Mini-Rack architecture designed to save space in high-density control cabinets.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e7-Slot Capacity:\u003c\/strong\u003e Accommodates standard 3500 series monitoring and power supply modules within a reduced footprint.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePanel Mount Configuration:\u003c\/strong\u003e Purpose-built bezel and mounting flange for direct integration into control panel cutouts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Integrity Backplane:\u003c\/strong\u003e Distributes operating power and manages system-wide digital bus communications without signal degradation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Compliance:\u003c\/strong\u003e Meets European safety and electromagnetic compatibility standards for harsh industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eVibration monitoring and asset protection for turbomachinery and generators.\u003c\/li\u003e\n  \u003cli\u003ePetrochemical and oil and gas pump, compressor, and fan diagnostic systems.\u003c\/li\u003e\n  \u003cli\u003eHydroelectric and thermal power plant rotating asset monitoring.\u003c\/li\u003e\n  \u003cli\u003eCritical industrial machinery protection requiring compact cabinet installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eOption Code\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eOption Description\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eSelected Configuration Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e02\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eRack Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e12-inch Mini-Rack (7 module slots)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e04\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eMounting Options\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePanel Mount Option, Mini-Rack\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e00\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eAgency Approval Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNone Specified\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e00\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eReserved Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNone\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e01\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eEuropean Compliance\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCE Certified\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eTechnical Value \/ Detail\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3500\/05-02-04-00-00-01\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSystem Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3500 Series Machinery Protection System\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePhysical Rack Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e12-inch Mini-Rack\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModule Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e7 slots (Includes dedicated power supply and rack interface slots)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eMounting Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePanel Mount (Front-secure installation)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eAgency Approvals\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eStandard Industrial (No hazardous area approvals specified)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCompliance Standards\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCE (European Conformity)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eUnited States (USA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e6.0 kg (13.2 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 12-inch Mini-Rack system limits module slots to 7 compared to the standard 19-inch 14-slot 3500\/05 rack. If your instrumentation loop expands to require additional monitoring channels, you must transition to a full-sized 19-inch 3500\/05 rack configuration. Standard 3500 series input modules and power supplies are backward compatible with this mini-rack backplane, provided that power requirements do not exceed the threshold of the installed mini-rack power supply units.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause panel-mounted units sit inside enclosed environmental cabinets, thermal management is critical. A fully populated 7-slot mini-rack containing dual power supplies and multiple processing monitors generates significant heat density. Maintain a minimum of 50mm (2.0 inches) of clearance above and below the rack chassis to ensure adequate convective air circulation. Avoid placing heat-sensitive field-wiring barriers directly above the exhaust path of the rack.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProper chassis grounding is vital to prevent high-frequency noise from corrupting low-voltage proximity probe and accelerometer signals. Connect a low-impedance copper ground strap directly from the designated rack grounding stud to the main panel safety ground bus. Do not rely solely on the panel-mounting screws for establishing an electrical ground pathway. All internal shield connections must be isolated and terminated according to Bently Nevada wiring diagrams to prevent ground loop interference.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e De-energize all primary, redundant, and field-contact power sources before attempting panel cutout prep or physical installation. Verify that no residual static charges are present on the cabinet housing. Failure to isolate power can result in equipment damage, system-wide trips of machinery protection relays, or severe electrical shock.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eMeasure and execute the panel cutout precisely according to the 12-inch Bently Nevada mini-rack dimensional template. deburr all raw metal edges.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003ePosition the rack bezel gasket to maintain cabinet environmental integrity, then insert the rack through the front cutout.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eSecure the mini-rack to the panel bezel using the recommended mounting screws and torque-tighten to ensure a secure, vibration-resistant fit.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the dedicated copper grounding strap to the chassis ground stud before installing modules or applying power to the backplane.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668307997035,"sku":"3500\/05-02-04-00-00-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-05-02-04-00-00-01-pl1ncmbohfx_b51ae41f-d0c1-432e-b5f7-21a9b1613a41.jpg?v=1765520738","url":"https:\/\/www.plcprotech.com\/de\/products\/bently-nevada-3500-05-02-04-00-00-01-3500-series-system-rack","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}