{"product_id":"bently-nevada-3500-05-02-05-00-00-01-3500-series-system-rack","title":"Bently Nevada 3500\/05-02-05-00-00-01 3500 Series System Rack","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding the structural chassis and essential backplane data pathways for machinery protection, the Bently Nevada 3500\/05-02-05-00-00-01 operates as a highly compact 7-slot mini rack. This specific hardware configuration is engineered to host a variety of 3500 series monitoring and power supply modules, facilitating real-time diagnostic communications and power distribution. By utilizing a physical 12-inch profile, it delivers industrial-grade machinery protection in applications where mounting space within standard control cabinets is strictly limited.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.25rem;\"\u003eCompact 12-inch frame configuration engineered with 7 individual module slots.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.25rem;\"\u003eHigh-speed backplane structure ensuring deterministic communications and power distribution between inserted modules.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.25rem;\"\u003eIntegrated mini-rack mounting options for reliable, vibration-resistant installation inside enclosures.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.25rem;\"\u003eCE compliant configuration suitable for European industrial plant applications.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.25rem;\"\u003eRugged metal construction protecting internal circuitry against Electromagnetic Interference (EMI) and harsh environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.25rem;\"\u003eTurbine supervisory instrumentation systems.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.25rem;\"\u003eCritical assets and rotating machinery diagnostics in power generation.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.25rem;\"\u003ePetrochemical plants requiring localized vibration monitoring and safety shutdown interfaces.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.25rem;\"\u003eModulated cabinet installations with strict physical footprint constraints.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eOption Code\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eSelection Detail\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e02\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e12-inch Mini-Rack (7 module slots)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e05\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eRack Mount Option, Mini-Rack\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e00\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eAgency Approval: None\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e00\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eReserved: None\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e01\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eEuropean Compliance Option: CE\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold; width: 35%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel\/Part Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3500\/05-02-05-00-00-01\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eChassis Form Factor\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e12-inch Mini-Rack\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePhysical Slots\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e7 module slots\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eMounting Mechanics\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eRack Mount configuration\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCompliance \u0026amp; Approvals\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCE Compliant\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eUnited States (U.S.A.)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e6.00 kg (13.23 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem; font-weight: bold;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eNote that the 3500 mini-rack utilizes a different physical backplane than standard 19-inch 14-slot configurations. While standard 3500 modules physically fit into the mini-rack, system planning must account for the limited slot count; certain high-density applications requiring extensive relay modules or dual redundant communications may exceed the 7-slot boundary.\u003c\/p\u003e\n\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem; font-weight: bold;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThermal dynamics inside compact 12-inch configurations require structured thermal budgets. High-draw modules such as seismic monitors or machinery diagnostics cards can generate localized heat. Ensure at least 1 U of ventilation space above and below the rack within the cabinet, and verify that overall cabinet ambient temperatures do not exceed the module-specific thresholds.\u003c\/p\u003e\n\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem; font-weight: bold;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProper chassis grounding is critical to guarantee instrument signal integrity. Always tie the dedicated ground lug on the rear of the rack to a verified single-point low-impedance instrument ground system. Do not daisy-chain safety grounds or run shield drain wires across high-voltage AC paths, as noise on the backplane can disrupt highly sensitive 3500 monitor signal measurements.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 12px; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-weight: bold;\"\u003eCRITICAL WARNING:\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 4px 0 0 0;\"\u003eDisconnect all primary power sources before performing mechanical installations. Verify that all power storage systems are discharged to prevent electrical shock or damage to internal rack backplane pins during cardinsertion.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eEnsure physical spacing inside the instrument panel accommodates the 12-inch profile and provides required cabling clearances for rear-facing terminations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eSecure the rack housing to the enclosure rails using industrial-grade fasteners, ensuring a robust, low-vibration contact points.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 12px;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eVerify module slot guides are aligned before gently inserting card assemblies, securing front panels to prevent physical movement.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668293841259,"sku":"3500\/05-02-05-00-00-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-05-02-05-00-00-01-0cblwkmxnyc_7d9bb482-6169-4b6b-9f7f-bb955969e441.jpg?v=1765520371","url":"https:\/\/www.plcprotech.com\/de\/products\/bently-nevada-3500-05-02-05-00-00-01-3500-series-system-rack","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}