{"product_id":"bently-nevada-9200-02-01-10-00-two-wire-seismoprobe-velocity-transducer","title":"Bently Nevada 9200-02-01-10-00 Two-Wire Seismoprobe Velocity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e9200-02-01-10-00\u003c\/strong\u003e is a two-wire velocity transducer engineered for continuous machinery vibration monitoring or periodic diagnostic measurements when paired with test instruments. This moving-coil device measures absolute casing vibration by generating a voltage proportional to the transducer's velocity. When selected with the integral cable configuration, the \u003cstrong\u003e9200-02-01-10-00 Seismoprobe\u003c\/strong\u003e provides superior resistance to corrosive environments, eliminating the need for external protective housings. It connects directly to monitoring systems to ensure dependable machinery protection and predictive maintenance data collection.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMoving-coil design providing a self-generated voltage output proportional to velocity without external power.\u003c\/li\u003e\n\u003cli\u003eTwo-wire electrical configuration simplifying field wiring over long distances.\u003c\/li\u003e\n\u003cli\u003eHigh resistance to corrosive atmospheres and environmental contaminants when equipped with the integral cable option.\u003c\/li\u003e\n\u003cli\u003eSupport for multi-angle mounting configurations optimized for specific directional vibration measurement.\u003c\/li\u003e\n\u003cli\u003eRugged mechanical housing designed to withstand harsh industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCasing vibration monitoring on industrial pumps, fans, and blowers.\u003c\/li\u003e\n\u003cli\u003ePredictive maintenance data collection on steam and gas turbines.\u003c\/li\u003e\n\u003cli\u003eContinuous protection systems for gearboxes and large electric motors.\u003c\/li\u003e\n\u003cli\u003eDiagnostic testing and structural vibration analysis in petrochemical and power generation plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel: 9200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Seismoprobe Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Mounting Angle \/ Minimum Operating Frequency: 45 +\/-2.5 degrees, 4.5 Hz (270 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector Option: Top mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Base Option: Circular; M10X1 stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: No approvals required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mV\/mm\/s (500 mV\/in\/s), +\/-5% at +22 degC (+72 degF) with 25 mm\/s (1 in\/s) machine casing vibration at 100 Hz (6000 cpm) with a 10 kilo ohm load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrom 4.5 Hz (270 cpm) to 1 kHz (60,000 cpm); +0, -3dB typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic Operating Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.54 mm (0.100 in) peak-to-peak maximum displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithstands 50 g peak maximum acceleration along nonsensitive axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransverse Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/-10% maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Leadwire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 meters (1,000 feet) maximum between transducer and 3300 or 3500 Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating \u0026amp; Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 degC to +121 degC (-20 degF to +250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 95% noncondensing; 100% non-submerged when ordered with integral cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase \u0026amp; Adapter Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnodized aluminum A204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGasket Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Material (Top\/Side)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCadmium-plated aluminum, neoprene, and silver-plated copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Torque (M10x1 base)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.6 N\u003ci\u003em (50 in\u003c\/i\u003elb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e102 mm (4 in) typical (depends on connector option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41 mm (1.6 in) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 grams (10.5 ounces) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePin A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive output signal (goes positive with respect to Pin B when case velocity moves toward connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePin B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative output signal \/ Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Alignment:\u003c\/strong\u003e Ensure the transducer is installed at its specified calibration angle (45 degrees for option 02) to maintain proper frequency and sensitivity accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque Application:\u003c\/strong\u003e Tighten the M10x1 circular mounting base to exactly 5.6 N\u003ci\u003em (50 in\u003c\/i\u003elb). Over-torquing can damage the internal components or casing threads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Avoid routing transducer cables parallel to high-voltage AC power lines to minimize electro-magnetic interference (EMI) injection into the signal path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Protection:\u003c\/strong\u003e For installations exposed to heavy washdowns or high humidity, utilize the integral cable option or properly seal the mating connector backshell to prevent liquid ingress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eStandard \/ Certification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN61326-1, Electrical Equipment for Measurement, Control, and Laboratory use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEuropean Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEMC Directive 2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666857193835,"sku":"9200-02-01-10-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-02-01-10-00-seismoprobe-velocity-transducers-252kh1riqh4_effdaec7-4446-4e7b-b85b-440c6de44474.jpg?v=1765449212","url":"https:\/\/www.plcprotech.com\/de\/products\/bently-nevada-9200-02-01-10-00-two-wire-seismoprobe-velocity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}