{"product_id":"ge-multilin-750-p5-g5-s5-hi-a20-g-e-feeder-management-relay","title":"GE Multilin 750-P5-G5-S5-HI-A20-G-E Abgangsmanagementrelais","description":"\u003ch3\u003eBeschreibung\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin 750-P5-G5-S5-HI-A20-G-E Feeder Management Relay\u003c\/strong\u003e is a digital relay intended for the management and primary protection and control of distribution feeders. The \u003cstrong\u003e750-P5-G5-S5-HI-A20-G-E\u003c\/strong\u003e provides comprehensive protection functions for feeders and backup protection for bus, transformers, and transmission lines in a draw-out construction. Equipment capabilities include phase, neutral, ground, and sensitive ground overcurrent protection, voltage and frequency monitoring, along with directional overcurrent control elements. The unit features 5 A phase current inputs, 5 A ground current inputs, a 5 A sensitive ground current input, high-range control power, eight 4–20 mA analog outputs, a green breaker closed LED, and an enhanced display with a 10BaseT Ethernet option. Integrated networking interfaces support ModBus RTU, DNP 3.0 Level 2, and ModBus RTU over TCP\/IP protocols to interface with SCADA, DCS, or PLC systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDraw-out Construction\u003c\/strong\u003e: Simplifies device installation, testing, and minimizes replacement downtime.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Current Protection\u003c\/strong\u003e: Integrates directional phase, neutral, ground, and sensitive ground time and instantaneous overcurrent elements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Ethernet Interface\u003c\/strong\u003e: Includes a 10BaseT Ethernet option alongside standard RS232, RS485, and RS422 serial communications ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Analog Outputs\u003c\/strong\u003e: Configured with eight isolated 4–20 mA analog output channels driven by programmable measured parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Range Power Supply\u003c\/strong\u003e: Accepts high-range control power inputs covering 88–300 VDC and 70–265 VAC at 48–62 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Monitoring\u003c\/strong\u003e: Offers built-in fault locator, oscillography waveform capture, event recording for up to 256 events, and data logging capabilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary protection and control for distribution feeders on solidly grounded, high impedance grounded, or resonant grounded systems.\u003c\/li\u003e\n\u003cli\u003eBus blocking\/interlocking schemes and bus transfer schemes.\u003c\/li\u003e\n\u003cli\u003eReserves\u003c\/li\u003e\n\u003cli\u003eHochgeschwindigkeitserkennung von Fehlern zur Begrenzung von Störlichtbögen.\u003c\/li\u003e\n\u003cli\u003eLastabwurfschemata auf Basis von Spannungs- und Frequenzelementen.\u003c\/li\u003e\n\u003cli\u003eSchutz der Verbindung dezentraler Erzeugungsanlagen (DG).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBestellinformationen\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBestellcode\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eBeschreibung\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e750\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasiseinheit des Abgangsschutzsystems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-A-Phasenstromeingänge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eG5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-A-Eingänge für Nullsequenz-Erdungsstrom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-A-Eingang für empfindlichen Erdungsstrom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStromversorgung mit erweitertem Bereich: 88–300 VDC, 70–265 VAC bei 48–62 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcht analoge 4–20-mA-Ausgänge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrüne LED für geschlossenen Leistungsschalter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eErweitertes Display mit Ethernet-10BaseT-Option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnische Spezifikationen\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpezifikation\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHersteller\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Multilin \/ GE Grid Solutions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhasen-\/Erdungs-\/empfindliche CT-Eingänge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-A-Sekundärwicklung\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0,01 bis 20 × CT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWandlerbereich des Phasen-\/Erdungs-CT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWandlerbereich des empfindlichen Erdungs-CT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0,005 bis 1,000 × CT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBürde des Stromeingangs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeniger als 0,2 VA bei 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEingänge für Bus-\/Leitungsspannung\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 V bis 240 V Phase-Neutralleiter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEingangsbereich der Steuerspannung (HI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88–300 VDC; 70–265 VAC bei 48–62 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLeistungsaufnahme\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 VA nominal, 35 VA maximal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eÜberbrückungszeit bei Spannungsverlust\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogikeingänge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 Kontakt- und\/oder virtuelle Eingänge, 6 nur virtuell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalogeingang\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–1 mA, 0–5 mA, 0–10 mA, 0–20 mA oder 4–20 mA (Impedanz 375 Ohm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnaloge Ausgänge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Kanäle aktiv, 4–20 mA (max. Last 600 Ohm), vollständig galvanisch getrennt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAusgangsrelais\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 AUSLÖSEN (Form A), 1 SCHLIESSEN (Form A), 5 HILFSKONTAKTE (Form C), 1 SELBSTTESTWARNUNG (Form C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHalbleiter-Auslösausgang\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A bei 250 VDC für 500 ms schalten und führen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerielle Kommunikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232 (Frontplatte), RS485 \/ RS422 (Rückseite), 300–19.200 Baud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet-Kommunikation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10BaseT, RJ45-Anschluss, ModBus RTU über TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnterstützte Protokolle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModBus RTU, DNP 3.0 Level 2, ModBus RTU TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBetriebstemperaturbereich\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 °C bis +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUmgebungslagertemperatur\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 °C bis +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeuchtigkeitsklasse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBetrieb bis 95 % (nicht kondensierend) bei 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSchutzart\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (Vorderseite), IP20 (Rückseite)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVerschmutzungsgrad\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallationsrichtlinien\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFür eine sichere Erdung den Erdungsanschluss direkt mit der Sicherheitserdungsmatte der Schaltanlage verbinden.\u003c\/li\u003e\n\u003cli\u003eFür RS485-, RS422- und analoge Signalleitungen müssen abgeschirmte Twisted-Pair-Kabel verwendet werden; die Kabelschirme dürfen nur am Ende der SPS bzw. des Computers geerdet werden.\u003c\/li\u003e\n\u003cli\u003eDie CT-Eingänge verfügen über automatische Kurzschlussklemmen, um offene CT-Stromkreise während des Herausziehens zu verhindern.\u003c\/li\u003e\n\u003cli\u003eBeim Anschließen der Steuerspannung an die Klemmen H11 und H12 die korrekte Polarität und die Spannungspegel überprüfen.\u003c\/li\u003e\n\u003cli\u003eDas Warnungs-Ausgangsrelais des Selbsttests als ausfallsichere Schaltung verdrahten; die Klemmen E12 und F12 öffnen, wenn die Steuerspannung anliegt und keine Selbsttestwarnungen vorhanden sind.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKonformität und Zertifizierungen\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ecULus\u003c\/strong\u003e: UL508, UL1053, C22.2 Nr. 14\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE\u003c\/strong\u003e: EN60255-5, EN50263\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration \/ Stoß\u003c\/strong\u003e: IEC 60255-21-1, IEC 60255-21-2, IEC 60255-21-3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSchutzart\u003c\/strong\u003e: IEC 60529\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53667860480363,"sku":"750-P5-G5-S5-HI-A20-G-E","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/750-P5-G5-S5-HI-A20-G-E_1200x1200_70e336ac-1b30-45d0-8cb8-32963a9d68e2.jpg?v=1785938037","url":"https:\/\/www.plcprotech.com\/de\/products\/ge-multilin-750-p5-g5-s5-hi-a20-g-e-feeder-management-relay","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}