{"product_id":"honeywell-10006-2-1-fsc-diagnostic-and-battery-module","title":"Honeywell 10006\/2\/1 FSC Diagnostic and Battery Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for seamless integration into Fail Safe Control (FSC) safety systems, the \u003cstrong\u003eHoneywell 10006\/2\/1\u003c\/strong\u003e serves as a reliable diagnostic and battery module (DBM). This unit, also referenced under part number \u003cstrong\u003e3400310\u003c\/strong\u003e, provides an engineered, cost-effective interface for diagnosing system health, executing runtime checks, and maintaining memory registers.\u003c\/p\u003e\n\n\u003cp\u003eThe module is equipped with an integrated real-time clock displaying minimal drift and a dedicated backup battery circuit to ensure continuous operation of critical system registers during power cycles. Engineered specifically for high-availability environments, variants bearing the 08801 suffix code feature enhanced electromagnetic noise immunity, making them highly suitable for electrically noisy industrial settings.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides a dedicated diagnostics interface for Honeywell FSC safety systems.\u003c\/li\u003e\n  \u003cli\u003eIntegrated real-time clock with an exceptionally low drift rate of less than 1 second per day.\u003c\/li\u003e\n  \u003cli\u003eOnboard 0.5 Ah backup battery capacity to safeguard system configuration data.\u003c\/li\u003e\n  \u003cli\u003eEnhanced noise immunity on units designated with suffix code 08801.\u003c\/li\u003e\n  \u003cli\u003eStandard 3U height and 8 HP width form factor for simple rack integration.\u003c\/li\u003e\n  \u003cli\u003eCompatible with FSC software versions 2.90 and higher.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEmergency Shutdown Systems (ESD)\u003c\/li\u003e\n  \u003cli\u003eBurner Management Systems (BMS)\u003c\/li\u003e\n  \u003cli\u003eFire and Gas Detection Systems\u003c\/li\u003e\n  \u003cli\u003eCritical Process Safety control in Oil \u0026amp; Gas and Petrochemical plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\n      \u003ctd\u003e10006\/2\/1 (3400310)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\n      \u003ctd\u003eHoneywell Fail Safe Control (FSC) System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eModule Type\u003c\/strong\u003e\n      \u003ctd\u003eDiagnostic and Battery Module (DBM)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eRequired Software Version\u003c\/strong\u003e\n      \u003ctd\u003e\u0026gt;= 2.90\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePower Supply\u003c\/strong\u003e\n      \u003ctd\u003e5 Vdc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\n      \u003ctd\u003e300 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eRipple Content\u003c\/strong\u003e\n      \u003ctd\u003e\u0026lt; 50 mV p-p\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eBack-up Battery Capacity\u003c\/strong\u003e\n      \u003ctd\u003e0.5 Ah\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eTime Clock Drift\u003c\/strong\u003e\n      \u003ctd\u003e\u0026lt; 1 second per day\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eModule Width (Space Requirement)\u003c\/strong\u003e\n      \u003ctd\u003e8 TE \/ HP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eModule Height (Space Requirement)\u003c\/strong\u003e\n      \u003ctd\u003e3 HE \/ U\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWeight\u003c\/strong\u003e\n      \u003ctd\u003e0.24 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge (ESD) Protection:\u003c\/strong\u003e Always wear an approved grounding wrist strap when handling the card to prevent ESD damage to delicate static-sensitive CMOS components.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChassis Mounting:\u003c\/strong\u003e Ensure the FSC rack chassis is powered down prior to inserting or removing the module to avoid diagnostic communication interruptions or backplane bus faults.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAlignment:\u003c\/strong\u003e Slide the module carefully along the guide rails of the designated 3U subrack slot until the rear DIN connector is completely mated with the backplane. Secure the front panel using the integral retaining screws.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBattery Commissioning:\u003c\/strong\u003e Check battery connection jumpers or software register states upon initial startup to verify that the 0.5 Ah backup circuit is fully engaged.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Compliant\u003c\/li\u003e\n  \u003cli\u003eTÜV Certified for Functional Safety\u003c\/li\u003e\n  \u003cli\u003eUL Listed\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705568817515,"sku":"10006\/2\/1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1000621-emxa4a23gm5_62634c0e-bb1c-4a47-8023-9d3ee08438e6.jpg?v=1766650078","url":"https:\/\/www.plcprotech.com\/de\/products\/honeywell-10006-2-1-fsc-diagnostic-and-battery-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}