{"product_id":"honeywell-51453328-501-uda-series-additional-analog-relay-card","title":"Honeywell 51453328-501 UDA Series Additional Analog \u0026 Relay Card","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding extended output capabilities for continuous process monitoring systems, this hardware expansion board, the \u003cstrong\u003eHoneywell 51453328-501\u003c\/strong\u003e, integrates directly into the host UDA2182 Universal Dual Analyzer chassis. This card increases the control and alarm-handling capabilities of your process analyzer by introducing supplementary auxiliary analog outputs and dedicated physical relay contacts, ensuring seamless signal transmission to distributed control systems (DCS) or auxiliary control loops.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eExpands host analyzer capabilities to support additional physical control and alarm loops.\u003c\/li\u003e\n  \u003cli\u003eProvides isolated analog output channels for highly reliable process variable retransmission.\u003c\/li\u003e\n  \u003cli\u003eIntegrated dry relay contacts configurable for high\/low alarms, diagnostics, or limit controls.\u003c\/li\u003e\n  \u003cli\u003eRuggedized field terminal blocks designed for secure industrial wire terminations.\u003c\/li\u003e\n  \u003cli\u003ePlug-and-play form factor simplifies field upgrades and minimizes system downtime.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eMunicipal water treatment facilities using Honeywell UDA2182 multi-parameter analyzers.\u003c\/li\u003e\n  \u003cli\u003eIndustrial boiler feed-water monitoring systems demanding auxiliary signal retransmission.\u003c\/li\u003e\n  \u003cli\u003eChemical processing plants requiring automated hardwired shutdown actions via relay interlocks.\u003c\/li\u003e\n  \u003cli\u003eWastewater neutralization and effluent monitoring systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; width: 35%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eHoneywell\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e51453328-501\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSeries Compatibility\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUDA2182 Universal Dual Analyzer\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAdditional Analog Output and Relay Card\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eI\/O Functionality\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAuxiliary Analog Output \u0026amp; Relay Contact Outputs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eInstallation Slot\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eInternal Dedicated Option Slot\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 51453328-501 card is specifically engineered for the UDA2182 analyzer series. When replacing older module revisions or retrofitting legacy analytical instrumentation, confirm that the host analyzer's firmware supports the additional analog and relay configuration options in the setup menu. Ensure the host unit's power supply capacity aligns with the overall system card loading before installation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo prevent cross-talk and measurement instability, signal loop cables must be isolated from high-voltage AC lines. Do not run low-voltage analog signal wires inside the same conduit as high-current relay switched lines. Inductive load switching with the on-board relays requires external snubber protection to avoid transient voltage feedback to the card circuitry.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eDisconnect all electrical power to the host analyzer and verify the absence of voltage before opening the enclosure door. Failure to isolate the power supplies can cause severe shock, card damage, or system-wide communication faults.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 0.75rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003ePower down the UDA2182 host analyzer and secure with lock-out\/tag-out procedures.\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 0.75rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eOpen the main housing and locate the designated option slot on the internal chassis.\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 0.75rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eCarefully align the edge connector of the 51453328-501 card with the motherboard socket and press firmly until fully seated.\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 0.75rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eSecure the card with mounting screws to prevent vibration-induced dislodgement.\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eTerminate the analog signal and relay loop cables onto the plug-in terminal blocks, ensuring correct polarity.\u003c\/span\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705602470251,"sku":"51453328-501","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/51453328-501-2ypwvhddfc1_27c299de-3a65-4da7-a16e-5ef6e2824606.jpg?v=1766651394","url":"https:\/\/www.plcprotech.com\/de\/products\/honeywell-51453328-501-uda-series-additional-analog-relay-card","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}