{"product_id":"honeywell-620-0081-ipc-620-data-hiway-interface-module","title":"Honeywell 620-0081 IPC 620 Data Hiway Interface Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eIntegrating legacy control networks requires reliable communication hardware, and the \u003cstrong\u003eHoneywell 620-0081\u003c\/strong\u003e serves as a dedicated Data Hiway Interface Module within the IPC 620 programmable logic controller system. This module establishes a robust gateway between local PLC racks and the broader Honeywell Data Hiway network, enabling deterministic, high-speed data exchange and centralized supervisory control.\u003c\/p\u003e\n\n\u003cp\u003eEngineered for demanding industrial process environments, this interface module manages complex protocol translation, transmission timing, and media access control without taxing the main PLC processor. The \u003cstrong\u003e620-0081\u003c\/strong\u003e slots directly into the standard 620 series chassis, utilizing system backplane power and communication buses to ensure low-latency signal distribution across distributed control systems (DCS) and legacy supervisory networks.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides direct backplane interfacing with Honeywell IPC 620 series rack assemblies.\u003c\/li\u003e\n  \u003cli\u003eEstablishes reliable, real-time communication with Honeywell Data Hiway networks.\u003c\/li\u003e\n  \u003cli\u003eEquipped with front-panel diagnostic LED indicators to facilitate rapid network status verification and troubleshooting.\u003c\/li\u003e\n  \u003cli\u003eFeatures dedicated co-processing capability to offload communication overhead from the primary system CPU.\u003c\/li\u003e\n  \u003cli\u003eHardware-configurable addressing switches for secure and distinct network node assignment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOil and Gas Refining\u003c\/li\u003e\n  \u003cli\u003eChemical Processing Plants\u003c\/li\u003e\n  \u003cli\u003ePower Generation Utilities\u003c\/li\u003e\n  \u003cli\u003ePulp and Paper Mills\u003c\/li\u003e\n  \u003cli\u003eDistributed Control System (DCS) legacy integrations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e620-0081\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIPC 620\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eData Hiway Interface Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.9 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Location\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIPC 620 Chassis \/ Rack Slot\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e Always de-energize the PLC chassis and associated backplane power supplies before inserting or extracting the module to prevent electrical damage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSlot Alignment:\u003c\/strong\u003e Ensure correct physical alignment with the chassis guides and backplane connectors before fully inserting the card.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Fasten the retaining screws to the chassis frame to ensure proper system grounding and protect against industrial vibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAddressing:\u003c\/strong\u003e Confirm that the hardware node address switches are correctly configured in accordance with your network map prior to system startup.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52679198245227,"sku":"620-0081","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/620-0081-y0ilasb0ho2_97311572-8732-4eea-9962-d1f4a73c449c.jpg?v=1765958068","url":"https:\/\/www.plcprotech.com\/de\/products\/honeywell-620-0081-ipc-620-data-hiway-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}