{"product_id":"honeywell-cc-tdil01-series-c-24v-digital-input-iota","title":"Honeywell CC-TDIL01 Series C 24V Digital Input IOTA","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEngineered for high-density discrete signal processing within the Experion PKS C300 control system, the Honeywell CC-TDIL01 serves as a robust 24V DC Digital Input Output Termination Assembly (IOTA). This hardware component provides physical connection interfaces between field wiring and \u003cstrong\u003eSeries C Digital Input Modules\u003c\/strong\u003e, ensuring clean and reliable signal conditioning for critical industrial control applications. Designed specifically for non-redundant \u003cstrong\u003e32-channel configurations\u003c\/strong\u003e, it manages field signals effectively while maintaining the strict electrical isolation and signal path integrity required in modern automated process control environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eKey Technical Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Density Architecture:\u003c\/strong\u003e Supports up to 32 discrete digital input termination channels on a single module footprint.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEngineered Integration:\u003c\/strong\u003e Plugs directly into the Series C chassis, allowing effortless physical mounting of the CC-PDIL01 input module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Voltage Handling:\u003c\/strong\u003e Native 24 VDC operating parameter with dedicated loop distribution pathways.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial-Grade Enclosure:\u003c\/strong\u003e Hardened circuit paths designed to resist structural deformation and thermal stresses in dense cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExperion PKS Systems:\u003c\/strong\u003e Standard termination interface for Series C I\/O sub-systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeavy Industry Control:\u003c\/strong\u003e Signal routing for petrochemical, oil and gas, and refining processes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiscrete Event Monitoring:\u003c\/strong\u003e Interfaces limit switches, motor auxiliary contacts, and proximity sensors to DCS logic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: 500;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eHoneywell\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: 500;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCC-TDIL01\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: 500;\"\u003eSeries Alignment\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSeries C \/ Experion PKS C300\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: 500;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDigital Input 24V IOTA (Input Output Termination Assembly)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: 500;\"\u003eChannel Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e32 Channels (Non-Redundant)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: 500;\"\u003eNominal Operating Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e24 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: 500;\"\u003eNominal Current Draw\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.190 A @ 24 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: 500;\"\u003eThermal Dissipation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e4.22 Watts\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: 500;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2d3748; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe CC-TDIL01 is standardly paired with the non-redundant Series C Digital Input Module CC-PDIL01. If your process requires high-availability configurations, you must select the CC-TDIL11 IOTA instead, which supports dual-redundant active\/standby module pairings. Attempting to fit redundant digital input modules onto the CC-TDIL01 is physically prevented by the single-socket board layout.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2d3748; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen routing field power through the CC-TDIL01, ensure the external power distribution lines are sized appropriately to handle cumulative current surges. Sudden load drops on field switches can trigger minor EMI transients across adjacent terminals on the assembly board if the system's power supply lacks adequate surge-damping characteristics.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2d3748; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003eEnsure that all cable shields are terminated at a single point, preferably at the cabinet ground bar, and never daisy-chained across the module's 24V common terminal blocks. During commissioning, loop resistance checks must be completed before inserting the CC-PDIL01 active module to prevent damage to internal sensing resistors from short circuits in the field wiring.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"font-weight: bold; color: #9b2c2c; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate and verify the de-energization of all active 24V DC loop feeds and main controller power lines prior to inserting or removing field cables from the CC-TDIL01. Failure to comply can damage the internal termination tracks or cause ESD-related failures on connected active logic modules.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 0.75rem; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; width: 24px; height: 24px; margin-right: 0.75rem; flex-shrink: 0; line-height: 24px;\"\u003e1\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the termination assembly securely onto the cabinet DIN rail and ensure proper grounding of the metal bracket.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 0.75rem; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; width: 24px; height: 24px; margin-right: 0.75rem; flex-shrink: 0; line-height: 24px;\"\u003e2\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eTerminate your discrete field wires at the designated terminals, adhering to the specified wire gauge limits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 0.75rem; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; width: 24px; height: 24px; margin-right: 0.75rem; flex-shrink: 0; line-height: 24px;\"\u003e3\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eVerify wiring integrity and check for any potential ground faults before aligning and pressing the digital input module into the card interface socket.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705338818923,"sku":"CC-TDIL01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cc-tdil01-xjp1jtqkun3_c1c2216f-f860-4e78-9160-9dbad145b5df.jpg?v=1766640906","url":"https:\/\/www.plcprotech.com\/de\/products\/honeywell-cc-tdil01-series-c-24v-digital-input-iota","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}