{"product_id":"honeywell-tsdo-0824-safety-manager-safe-digital-output-fta","title":"Honeywell TSDO-0824 Safety Manager Safe Digital Output FTA","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TSDO-0824\u003c\/strong\u003e is a high-reliability \u003cstrong\u003eSafe Digital Output Field Termination Assembly (FTA)\u003c\/strong\u003e module specifically engineered for integration within the \u003cstrong\u003eHoneywell Safety Manager\u003c\/strong\u003e platform. This module acts as the dedicated physical and electrical interface connecting the system interconnection cable \u003cstrong\u003eSICC-0001\/Lx\u003c\/strong\u003e directly to external field circuitry via robust onboard screw terminals.\u003c\/p\u003e\n\u003cp\u003eDesigned to support critical safety-instrumented functions, the \u003cstrong\u003eTSDO-0824\u003c\/strong\u003e handles the eight independent channels of a single or redundant pair of \u003cstrong\u003eSDO-0824\u003c\/strong\u003e safe digital output modules. The assembly features a universal snap-in mounting provision designed for standard DIN EN rails, offering structured, secure, and vibration-resistant field terminal assignments for high-availability industrial safety applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSeamlessly interfaces 8 independent safe digital output channels to the field.\u003c\/li\u003e\n\u003cli\u003eDesigned as the direct terminal companion for the SICC-0001\/Lx system interconnection cable.\u003c\/li\u003e\n\u003cli\u003eFully supports redundant pairing topologies with SDO-0824 safety output modules.\u003c\/li\u003e\n\u003cli\u003eIntegrated universal snap-in hardware for secure and direct DIN rail mounting.\u003c\/li\u003e\n\u003cli\u003eDurable built-in screw terminal blocks provide standard, gas-tight field wiring connections.\u003c\/li\u003e\n\u003cli\u003eConfirmed high electrical compliance matching overvoltage category 3 parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSafety Instrumented Systems (SIS)\u003c\/li\u003e\n\u003cli\u003eEmergency Shutdown Systems (ESD)\u003c\/li\u003e\n\u003cli\u003eBurner Management Systems (BMS)\u003c\/li\u003e\n\u003cli\u003eHigh-integrity Fire and Gas (F\u0026amp;G) output systems\u003c\/li\u003e\n\u003cli\u003eDistributed Control System (DCS) safety loop interlocks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eProduct Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eTSDO-0824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eSafe Digital Output FTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eSystem Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eSafety Manager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e36 Vdc – IEC 1010 (1990), overvoltage category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003eMaximum Continuous Current per Channel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003cstrong\u003eActual Maximum Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eDefined by connected output module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003eDIN EN Rails\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eTS32 \/ TS35 x 7.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003eUsed Rail Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e171 mm (6.73 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003cstrong\u003eScrew Terminals Max Wire Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e2.5 mm² (AWG 14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003cstrong\u003eScrew Terminals Strip Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e7 mm (0.28 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e\u003cstrong\u003eScrew Terminals Tightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e0.5 Nm (0.37 ft-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003e\u003cstrong\u003eModule Dimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e170 x 70 x 64 mm (6.72 x 2.76 x 2.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e3 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003eNetherlands\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Installation:\u003c\/strong\u003e Snap the module firmly onto standard TS32 or TS35 x 7.5 DIN EN rails. Verify that the targeted rail segment leaves at least 171 mm of usable horizontal space to properly accommodate the base alignment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Termination:\u003c\/strong\u003e Plug the multi-pin interface plug of the SICC-0001\/Lx system interconnection cable completely into the module's onboard SIC header to establish the internal link with the SDO-0824 output modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Connection:\u003c\/strong\u003e Carefully strip field conductor ends to a precise length of 7 mm (0.28 in). Insert the conductors into the terminal blocks (accepting up to 2.5 mm² \/ AWG 14 max wire size) and securely tighten the screws to a nominal torque of 0.5 Nm (0.37 ft-lb).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Protection:\u003c\/strong\u003e Mount the assembly within a clean, climate-controlled electrical panel or marshalling cabinet to provide appropriate moisture, environmental dust protection, and effective shielding against industrial EMI\/RFI noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eTUV\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary role of the TSDO-0824 module in a safety system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt acts as the physical field termination assembly interface that bridges the Honeywell Safety Manager system interconnection cabling to the external field equipment wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many output channels are built into this termination assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is equipped with exactly 8 safe digital output channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich system cable must be used to connect this FTA to the system rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis module requires the standard SICC-0001\/Lx system interconnection cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this field termination module handle redundant output signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it can seamlessly accommodate the eight combined channels of a redundant pair of SDO-0824 modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum absolute voltage limit permitted for the field contacts?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe maximum voltage limit is defined as 36 Vdc under IEC 1010 (1990) overvoltage category 3 parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the TSDO-0824 strictly limit channel current to 1.5 A?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the hardware continuous current limit per channel is 1.5 A, the actual maximum current limit is determined by the specific output module connected upstream.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific profile types of DIN EN rails can this module be snapped onto?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated universal snap-in assembly is fully compatible with TS32 and TS35 x 7.5 DIN EN rails.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much horizontal space on the DIN rail does the unit require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module has a specified used rail length of 171 mm (6.73 inches).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the required insulation stripping length for preparing field wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExternal field wires must be stripped to an exact length of 7 mm (0.28 inches) before termination.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat torque level should be applied when securing the field screws?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAll onboard field screw terminals must be tightened to a torque rating of 0.5 Nm (0.37 ft-lb).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum allowable wire gauge size for the terminal block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe terminal blocks accept a maximum solid or stranded conductor diameter up to 2.5 mm², which matches AWG 14.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat independent product testing certifications does this hardware hold?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe field termination assembly holds official, fully verified approvals from CE, TUV, UL, CSA, and FM.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705608630635,"sku":"TSDO-0824","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tsdo-0824-toddfz1fpf4_4f3793ea-35c1-4573-b698-b3af9d8215ca.jpg?v=1766651573","url":"https:\/\/www.plcprotech.com\/de\/products\/honeywell-tsdo-0824-safety-manager-safe-digital-output-fta","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}