{"product_id":"lenze-e82ev371-2b-8200-vector-variable-frequency-drive","title":"Lenze E82EV371_2B 8200 Vector Variable Frequency Drive","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding precise speed and torque control for industrial three-phase motors, the \u003cstrong\u003eLenze E82EV371_2B\u003c\/strong\u003e is a modular frequency inverter designed for high-efficiency operation within automated architectures. This unit, belonging to the respected \u003cstrong\u003e8200 Vector\u003c\/strong\u003e series, delivers a rated power output of \u003cstrong\u003e0.37 kW\u003c\/strong\u003e and features integrated interference suppression measures to maintain electromagnetic compatibility in demanding electrical environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003eIntegrated radio frequency interference (RFI) suppression filters to minimize electrical noise.\u003c\/li\u003e\n  \u003cli\u003eVector control processing for optimized torque characteristics at low rotational speeds.\u003c\/li\u003e\n  \u003cli\u003eModular interface slot allowing seamless integration of fieldbus communication modules.\u003c\/li\u003e\n  \u003cli\u003eCompact physical footprint designed for space-optimized control cabinet layouts.\u003c\/li\u003e\n  \u003cli\u003eRobust thermal management and protection circuits against overvoltage, undervoltage, and motor overload.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003eMaterial handling systems and small conveyor belts.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and labeling systems.\u003c\/li\u003e\n  \u003cli\u003eIndustrial fan and centrifugal pump speed regulation.\u003c\/li\u003e\n  \u003cli\u003eAuxiliary machine tool positioning and feed drives.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eLenze\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Reference\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eE82EV371_2B (E82EV371K2B)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e8200 Vector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMains Connection Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3 x 230 V AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRated Power Output\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.37 kW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInterference Suppression\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIntegrated filter measures\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Lifecycle Phase\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePhase-Out (Legacy support active)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e6.00 x 14.00 x 12.00 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.80 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e85044095\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eExport Control Classification\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eECCN: N\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eTerminal Designation\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eL1, L2, L3\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3-Phase AC Mains Input Connection (230 V)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eU, V, W\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3-Phase Motor Output Connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePE\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eProtective Earth Grounding Terminal\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe E82EV371_2B is functionally identical to the model reference E82EV371K2B, where the \"K\" designates the decimal placement for its 0.37 kW rating. When replacing older 8200 series units, ensure that any pluggable communication modules (such as CANopen or PROFIBUS FIF modules) are retained and transferred to the replacement unit, as the base power module does not include communication interfaces by default.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause this VFD is in its legacy phase-out lifecycle, thermal management is critical when retrofitting older enclosures. Ensure a minimum clearance of 100 mm above and below the drive to prevent heat buildup, as the internal heatsink relies heavily on unobstructed vertical convection currents.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo maintain the effectiveness of the integrated interference suppression filter, always use low-capacitance shielded motor cables. The shield must be grounded with a 360-degree metal clamp directly to the mounting plate as close to the drive's PE terminal as possible to minimize high-frequency electromagnetic interference.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate all electrical power sources before commencing installation or maintenance. After disconnecting the mains supply, wait at least 5 minutes for the internal DC-bus capacitors to discharge completely to safe voltage levels before touching any electrical terminals.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eMount the drive vertically on a flat, conductive, and grounded metal mounting plate inside an IP54 or higher rated control cabinet.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the protective earth (PE) conductor to the designated grounding terminal before making any other wiring connections.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eWire the 3-phase 230 V AC mains input to terminals L1, L2, and L3, and the motor leads to terminals U, V, and W using shielded cables.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105052451179,"sku":"E82EV371_2B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82ev371-2b-mvtpq5mlqfk.png?v=1776235843","url":"https:\/\/www.plcprotech.com\/de\/products\/lenze-e82ev371-2b-8200-vector-variable-frequency-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}