{"product_id":"lenze-e82zafpc-8200-series-communication-module","title":"Lenze E82ZAFPC 8200-series Communication Module","description":"\u003ch1\u003eLenze E82ZAFPC 8200-series Communication Module\u003c\/h1\u003e\n\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned to facilitate seamless fieldbus integration, the \u003cstrong\u003eLenze E82ZAFPC\u003c\/strong\u003e serves as a dedicated \u003cstrong\u003ePROFIBUS communication module\u003c\/strong\u003e for the 8200-series frequency inverters. This interface module enables direct connection of the drive controller to a PROFIBUS-DP network, allowing for high-speed cyclic process data exchange and acyclic parameter access. By integrating this module into your control architecture, operators can achieve centralized control, real-time diagnostics, and remote parameterization of the connected drive systems from a master PLC or distributed control system.\u003c\/p\u003e\n\n\u003cp\u003eEngineered for industrial environments, the module mounts directly onto the application interface (AIF) slot of the 8200-series vector inverters. This plug-and-play design minimizes wiring complexity and reduces installation time, making it a reliable choice for both new system deployments and legacy machinery retrofits.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect compatibility with Lenze 8200-series vector frequency inverters.\u003c\/li\u003e\n  \u003cli\u003eSupports the standard PROFIBUS-DP communication protocol for high-speed data transmission.\u003c\/li\u003e\n  \u003cli\u003eEnables both cyclic process data transfer and acyclic parameter configuration.\u003c\/li\u003e\n  \u003cli\u003eCompact, plug-on design that mounts directly into the drive's AIF slot.\u003c\/li\u003e\n  \u003cli\u003eIntegrated diagnostic indicators for quick network and communication status verification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFactory automation and centralized machine control.\u003c\/li\u003e\n  \u003cli\u003eConveyor systems and material handling applications.\u003c\/li\u003e\n  \u003cli\u003ePumping, ventilation, and HVAC systems utilizing legacy Lenze drives.\u003c\/li\u003e\n  \u003cli\u003eRetrofitting and maintenance of existing production lines requiring fieldbus connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\n      \u003ctd\u003eE82ZAFPC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eSeries\u003c\/strong\u003e\n      \u003ctd\u003e8200-series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eModule Type\u003c\/strong\u003e\n      \u003ctd\u003ePROFIBUS Communication Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eWeight\u003c\/strong\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCommodity Code\u003c\/strong\u003e\n      \u003ctd\u003e85044086\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure safe and reliable operation, adhere to the following engineering guidelines during installation:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e Ensure the host frequency inverter is completely powered down and that the DC-bus capacitors have fully discharged before inserting or removing the communication module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Plug the E82ZAFPC module firmly into the designated AIF slot on the front of the 8200-series inverter. Secure the module using the integrated retaining screws to guarantee proper grounding and mechanical stability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Use high-quality, shielded twisted-pair cables compliant with PROFIBUS standards. Ensure the cable shield is grounded over a wide area at both ends of the connection to prevent electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAddressing:\u003c\/strong\u003e Configure the station address using the onboard DIP switches or via the drive's internal parameters prior to commissioning the network.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105050059115,"sku":"E82ZAFPC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82zafpc-hd3diiz5001.png?v=1776235993","url":"https:\/\/www.plcprotech.com\/de\/products\/lenze-e82zafpc-8200-series-communication-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}