{"product_id":"lenze-e82zafsc-8200-series-analog-i-o-function-module","title":"Lenze E82ZAFSC 8200-series Analog I\/O Function Module","description":"\u003ch1\u003eLenze E82ZAFSC 8200-series Analog I\/O Function Module\u003c\/h1\u003e\n\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned to expand the control capabilities of Lenze 8200 vector frequency inverters, the \u003cstrong\u003eE82ZAFSC\u003c\/strong\u003e function module provides a versatile interface for analog and digital control signals. This plug-in module mounts directly onto the inverter's front interface slot, enabling seamless integration with external sensors, PLCs, and actuators. By supporting both analog and digital I\/O channels, it facilitates precise speed control, status monitoring, and system integration without requiring external signal converters.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eE82ZAFSC\u003c\/strong\u003e is engineered for high reliability in demanding industrial environments, ensuring stable signal transmission and robust noise immunity. It serves as a cost-effective expansion option for legacy automation setups utilizing the 8200 vector drive series, maintaining operational efficiency and system longevity.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect plug-in installation on the front interface slot of Lenze 8200 vector frequency inverters.\u003c\/li\u003e\n  \u003cli\u003eEquipped with 1 analog input configurable for voltage or current signals.\u003c\/li\u003e\n  \u003cli\u003eProvides 1 analog output (0 to 10 V) for feedback or monitoring.\u003c\/li\u003e\n  \u003cli\u003eFeatures 4 digital inputs for control commands such as start\/stop, direction, and preset speeds.\u003c\/li\u003e\n  \u003cli\u003eIncludes 1 digital output for status signaling and fault reporting.\u003c\/li\u003e\n  \u003cli\u003eInternal power supply drawn directly from the host inverter's interface slot.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSpeed and torque control in conveyor systems and material handling.\u003c\/li\u003e\n  \u003cli\u003eIntegration of pressure, flow, and temperature sensors in pump and fan applications.\u003c\/li\u003e\n  \u003cli\u003eGeneral industrial automation and machine control using Lenze 8200 vector drives.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eParameter\u003c\/strong\u003e\n      \u003cstrong\u003eValue\u003c\/strong\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\/Model\u003c\/td\u003e\n      \u003ctd\u003eE82ZAFSC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSeries\u003c\/td\u003e\n      \u003ctd\u003e8200-series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eStandard I\/O Function Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n      \u003ctd\u003e1 (0 to 10 V, 0 to 20 mA, 4 to 20 mA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n      \u003ctd\u003e1 (0 to 10 V)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Inputs\u003c\/td\u003e\n      \u003ctd\u003e4 (PLC level, HTL)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Outputs\u003c\/td\u003e\n      \u003ctd\u003e1 (PLC level, HTL)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e5.10 x 7.60 x 2.50 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.05 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Designation\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e1U\u003c\/td\u003e\n      \u003ctd\u003eAnalog Input (0 to 10 V)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e1I\u003c\/td\u003e\n      \u003ctd\u003eAnalog Input (0 to 20 mA or 4 to 20 mA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e2U\u003c\/td\u003e\n      \u003ctd\u003eAnalog Output (0 to 10 V)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE1\u003c\/td\u003e\n      \u003ctd\u003eDigital Input 1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE2\u003c\/td\u003e\n      \u003ctd\u003eDigital Input 2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE3\u003c\/td\u003e\n      \u003ctd\u003eDigital Input 3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE4\u003c\/td\u003e\n      \u003ctd\u003eDigital Input 4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA1\u003c\/td\u003e\n      \u003ctd\u003eDigital Output 1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGND\u003c\/td\u003e\n      \u003ctd\u003eReference Ground\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure the host inverter is completely powered down and the DC bus capacitors are fully discharged before inserting or removing the module.\u003c\/li\u003e\n  \u003cli\u003ePlug the E82ZAFSC module firmly into the designated slot on the front of the 8200 vector inverter.\u003c\/li\u003e\n  \u003cli\u003eSecure the module using the integrated retaining screws to ensure reliable grounding and mechanical stability.\u003c\/li\u003e\n  \u003cli\u003eRoute analog signal cables separately from high-voltage motor and power lines to prevent electromagnetic interference. Use shielded cables for all analog connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105047732587,"sku":"E82ZAFSC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82zafsc-2trqe2yiywt.png?v=1776236025","url":"https:\/\/www.plcprotech.com\/de\/products\/lenze-e82zafsc-8200-series-analog-i-o-function-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}