{"product_id":"mitsubishi-electric-fx3ge-40mt-es-melsec-fx3g-series-programmable-controller","title":"Mitsubishi Electric FX3GE-40MT\/ES MELSEC FX3G Series Programmable Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eManaging complex industrial tasks with localized automation is streamlined using the \u003cstrong\u003eMitsubishi Electric FX3GE-40MT\/ES\u003c\/strong\u003e programmable logic controller. This compact, all-in-one base unit integrates high-performance microprocessing with built-in digital inputs, transistor outputs, analog processing, and dual communication interfaces. Engineered as an extension of the reliable MELSEC FX3G architecture, this controller features embedded \u003cstrong\u003eEthernet and USB\u003c\/strong\u003e ports, eliminating the need for external expansion cards in space-constrained control panels.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eHigh-Speed Processing:\u003c\/strong\u003e Incorporates dual-layer architecture supporting standard program capacity up to 32,000 steps.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eBuilt-In Ethernet:\u003c\/strong\u003e Standard RJ45 port supporting 10BASE-T\/100BASE-TX for seamless SCADA, HMI, and network integration.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eIntegrated Analog I\/O:\u003c\/strong\u003e Factory-configured with 2 channels of analog input and 1 channel of analog output.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003ePositioning Capabilities:\u003c\/strong\u003e High-speed counter inputs up to 60 kHz and positioning pulse outputs up to 100 kHz.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eFlexible Expansion:\u003c\/strong\u003e Scalable layout utilizing FX3 series expansion boards and special function blocks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003ePackaging and automated sealing systems.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eLocal water treatment plants and pumping stations.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eConveyor networks and automated materials handling.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eHVAC monitoring and remote telemetry systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; font-family: sans-serif; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMitsubishi Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel \/ Article Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eFX3GE-40MT\/ES\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMELSEC FX3GE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRated Power Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e100 to 240 V AC (+10% \/ -15%), 50\/60 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTotal Integrated I\/O Points\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e40 points\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDigital Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 Inputs (24V DC, Sink\/Source selected by terminal)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDigital Outputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e16 Outputs (Transistor, Sink)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eIntegrated Analog Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2 Channels (0-10V DC \/ 4-20mA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eIntegrated Analog Outputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1 Channel (0-10V DC \/ 4-20mA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCommunication Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eEthernet (RJ45), USB (Mini-B), RS-422\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMemory Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e32,000 steps internal EEPROM program memory\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 to 55 degC (32 to 131 Fahrenheit)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.8 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e175 mm x 90 mm x 86 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; font-family: sans-serif; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d;\"\u003eTerminal Label\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d;\"\u003eFunction \/ Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eL \/ N\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e100-240 V AC Main Power Supply input\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e24V \/ 0V\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eAuxiliary 24V DC sensor power output supply\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eS\/S\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSink\/Source selector terminal for digital inputs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eX000 - X027\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24V DC Digital Inputs (high-speed counters on first channels)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eY000 - Y017\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTransistor Sink Outputs (pulse output functionality on Y000-Y002)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eV1+, I1+, VI1-, V2+, I2+, VI2-\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eAnalog Inputs (Channel 1 and Channel 2 voltage\/current terminals)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eV3+, I3+, VI3-\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eAnalog Output (Channel 3 voltage\/current terminals)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe FX3GE-40MT\/ES offers a direct physical upgrade path for older FX1N-40MT-D and standard FX3G-40MT\/ES micro-controllers. Existing FX3G ladder code is fully backward compatible. However, to access the built-in Ethernet parameters and configure analog channels directly without from\/to instructions, software development must be completed in GX Works2 (version 1.98 or later).\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis controller features standard Transistor Sink outputs (indicated by the MT suffix). Connecting field loads wired as sink logic to an improper polarity source will destroy the internal optocouplers. Ensure that external auxiliary power supplies are properly bonded. Thermal dissipation issues can manifest inside sealed control cabinets if the unit is installed horizontally; strictly adhere to vertical wall-mount layouts allowing a minimum clearance of 50mm above and below the chassis for natural convection airflow.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo prevent electrical noise interference on the integrated analog channels, always separate the 0-10V \/ 4-20mA routing from high-current AC power cables. Run shielded twisted-pair (STP) wiring for analog loops and terminate the shield ground \u003cstrong\u003estrictly at the PLC end\u003c\/strong\u003e to block localized ground loop currents from destabilizing sensor values.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/p\u003e\n  \u003cp style=\"margin: 5px 0 0 0; color: #9b2c2c; font-size: 0.95rem;\"\u003eIsolate all main power sources prior to conducting installation, mounting, or termination work. Failure to de-energize external circuits can cause severe electrical shock, hardware failure, or unexpected movement of connected actuators.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eMount the controller onto a standard 35mm DIN rail or secure it to a flat backplate using integrated M4 mounting screw points.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eConnect the main 100-240 V AC supply source to the terminal block, ensuring correct protective grounding (PE) alignment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eWire input lines with the selected active polarity (Sink or Source orientation configured through the S\/S terminal).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eConnect program transmission via Ethernet or USB, launch GX Works2, and run diagnostic procedures to verify hardware registers.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102305149291,"sku":"FX3GE-40MT\/ES","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fx3ge-40mtes-vjt5c1uaahf.png?v=1776137538","url":"https:\/\/www.plcprotech.com\/de\/products\/mitsubishi-electric-fx3ge-40mt-es-melsec-fx3g-series-programmable-controller","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}