{"product_id":"mitsubishi-electric-hg-sn202j-s100-melservo-je-series-servo-motor","title":"Mitsubishi Electric HG-SN202J-S100 MELSERVO JE Series Servo Motor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nDelivering precise motion control in high-inertia industrial environments, the Mitsubishi Electric HG-SN202J-S100 AC servo motor provides a rated output of \u003cstrong\u003e2.0 kW\u003c\/strong\u003e and comes equipped with a factory-installed \u003cstrong\u003eoil seal\u003c\/strong\u003e. This motor is engineered to operate seamlessly with matching MELSERVO-JE amplifiers, offering dynamic response and robust protection under challenging factory conditions. Its totally enclosed, naturally cooled design ensures long-term reliability in demanding automated applications.\n\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eHigh-Inertia Design:\u003c\/strong\u003e Well-suited for heavy-load operations, providing stable speed control and high-accuracy positioning.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eIP67 Environmental Protection:\u003c\/strong\u003e The dust-tight and water-resistant enclosure is designed for wet or dirty manufacturing bays.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eIntegrated Oil Seal:\u003c\/strong\u003e Provides robust protection against gear oil and cutting fluid migration along the motor shaft.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eOptimized Thermal Performance:\u003c\/strong\u003e Built with Class 155 (F) insulation to withstand continuous cycle-duty heat generation without degradation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eHeavy-duty gantry axes and automated transfer systems.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eMaterial handling conveyors, lifters, and packaging equipment.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eTension-control machinery, wire-drawing systems, and winders.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d; width: 40%;\"\u003eManufacturer\u003c\/th\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eMitsubishi Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eModel\u003c\/th\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eHG-SN202J-S100\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eSeries\u003c\/th\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eMELSERVO-JE (HG-SN Series)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eRated Output\u003c\/th\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2.0 kW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eRated Torque\u003c\/th\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e9.55 N-m\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eRated Speed\u003c\/th\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2000 r\/min\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eMaximum Speed\u003c\/th\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3000 r\/min\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eRated Current\u003c\/th\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e9.6 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eMaximum Current\u003c\/th\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e31 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eOil Seal\u003c\/th\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eInstalled (J-Type)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eInsulation Class\u003c\/th\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e155 (Class F)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eIngress Protection Rating\u003c\/th\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP67 (excluding shaft through-portion)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eOperating Temperature\u003c\/th\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 to 40 Celsius (non-freezing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003ePermissible Load Inertia Ratio\u003c\/th\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e15 times or less (motor inertia ratio)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eVibration Resistance\u003c\/th\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eX: 24.5 m\/s2, Y: 49 m\/s2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eNet Weight\u003c\/th\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e11 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold; color: #1a365d;\"\u003eShipping Weight\u003c\/th\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e12 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe HG-SN202J-S100 is engineered specifically for pairing with the \u003cstrong\u003eMR-JE-200A\u003c\/strong\u003e and \u003cstrong\u003eMR-JE-200B\u003c\/strong\u003e servo amplifiers. When replacing older HC-SFS series motors, confirm the shaft dimensions and encoder connector style, as the newer HG-SN series utilizes different termination plugs. Additionally, ensure the controller firmware is updated to recognize the 131072 pulses\/rev incremental encoder built into this motor.\n\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nAlthough this unit is rated at IP67, the shaft passage is not fully waterproof. Overlooking the application of an appropriate gear-box seal or failing to maintain a downward-facing cable orientation can allow oil or moisture to collect at the shaft interface and eventually breach the motor housing. For continuous S1 duty cycles in enclosed control cabinets, ensure the mounting plate has a minimum surface area equivalent to a 400mm x 400mm x 12mm aluminum plate to serve as an adequate heat sink.\n\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nWhen wiring the HG-SN202J-S100, ensure you do not run encoder cables in the exact same conduit or wire duct as high-voltage motor power lines. Electromagnetic interference (EMI) can corrupt encoder feedback signals and trigger amplifier fault codes. It is highly recommended to use genuine, shielded Mitsubishi cable assemblies with correct grounding brackets. If the motor is mounted vertically, form a drip loop in the cables to prevent liquids from running down to the connectors.\n\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Never perform any installation or maintenance on the servo motor or drive amplifier while mains power is applied. Wait at least 20 minutes after de-energization for the internal capacitors on the servo drive to fully discharge. Always measure the DC bus voltage to ensure it is below 50V before touching any terminal connections.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003e\n    \u003cstrong\u003eMechanical Alignment:\u003c\/strong\u003e Securely mount the motor to a flat, vibration-damped surface using the integrated mounting flange. Use a flexible coupling for direct-drive setups to prevent excessive radial or axial force on the shaft.\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003e\n    \u003cstrong\u003eWiring Connections:\u003c\/strong\u003e Secure the dedicated power cable (U, V, W, and PE) and encoder feedback cable. Confirm the PE (Protective Earth) terminal is securely grounded to prevent ground loops and high-frequency noise.\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003e\n    \u003cstrong\u003eOil Seal Check:\u003c\/strong\u003e For motors equipped with an oil seal, apply a thin layer of high-temperature grease on the lip of the seal to prevent dry-running damage during initial system commissioning.\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102152876395,"sku":"HG-SN202J-S100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/hg-sn202j-s100-vv2pzvr0edu.png?v=1776137706","url":"https:\/\/www.plcprotech.com\/de\/products\/mitsubishi-electric-hg-sn202j-s100-melservo-je-series-servo-motor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}