{"product_id":"omron-c200hs-cpu01-sysmac-c200hs-series-cpu-module","title":"Omron C200HS-CPU01 Sysmac C200HS Series CPU Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eManaging complex localized industrial automation processes, the \u003cstrong\u003eOmron C200HS-CPU01\u003c\/strong\u003e functions as a high-performance central processing unit within the legacy Sysmac C200H platform. Designed to execute ladder logic programs with high efficiency, this controller features an integrated program capacity of \u003cstrong\u003e15,200 words\u003c\/strong\u003e and a dedicated Data Memory (DM) area of \u003cstrong\u003e3,000 words\u003c\/strong\u003e. It is designed to mount directly into standard \u003cstrong\u003eC200H-BC series backplanes\u003c\/strong\u003e and supports up to \u003cstrong\u003e800 local and expansion I\/O points\u003c\/strong\u003e, making it ideal for maintaining and scaling existing assembly line, packaging, and material handling systems without requiring full system re-engineering.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Memory Capacity:\u003c\/strong\u003e Provides 15,200 words of program capacity and 3,000 words of DM area to handle complex instruction sets.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBroad I\/O Capabilities:\u003c\/strong\u003e Supports up to 800 maximum I\/O points when configured with compatible expansion modules and backplanes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Installs directly into Omron C200H-BC series backplanes for easy retrofitting.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eData Preservation:\u003c\/strong\u003e Equipped with an internal battery backup system to safeguard volatile memory and register status during power interruptions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard Programming:\u003c\/strong\u003e Utilizes standard ladder logic programming languages via Sysmac support software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eFactory automation systems utilizing existing Omron C200H hardware architectures.\u003c\/li\u003e\n  \u003cli\u003eConveyor and material handling control sequences.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and product positioning equipment.\u003c\/li\u003e\n  \u003cli\u003eRetrofits, hot-swaps, and hardware lifecycle extension in heavy industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eModel Number\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eC200HS-CPU01\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eSeries\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSysmac C200HS\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eProduct Type\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eProgrammable Controller CPU Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eProgram Capacity\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e15,200 words\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eData Memory (DM) Area\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3,000 words\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eExpansion Memory (EM)\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNone\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eMaximum I\/O Capacity\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e800 points (using expansion backplanes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eBuilt-in RS-232C Port\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNo\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eProgramming Language\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eLadder Logic\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eMounting Interface\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eC200H-BC Series Backplane\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eBattery Backup\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eYes (Requires periodic battery maintenance)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe C200HS-CPU01 serves as a high-speed upgrade over legacy C200H-CPU01 modules. While physical mounting layouts are identical, note that instruction execution times are significantly faster on C200HS models. If upgrading, carefully review time-dependent subroutines and pulse instruction loops, as the reduced scan times may require adjustment within your ladder program to ensure identical peripheral response.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis CPU does not feature a built-in RS-232C port or support internal option boards directly. If serial communications or host computer linkages are required, you must integrate a dedicated Host Link Unit (such as the C200H-LK201-V1) or an ASCII Module on the backplane. Ensure the backplane's power supply unit provides sufficient current output to handle the CPU and all peripheral cards simultaneously.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways perform a complete RAM upload (program and DM registers) via CX-Programmer or a Handheld Programming Console before attempting a CPU replacement. A low-battery indicator on the front panel indicates the memory-backup battery (typically 3G2A9-BAT08) requires physical replacement. Replace the battery only while the controller is powered on, or within 5 minutes of powering down, to prevent memory loss.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate and disconnect all external AC and DC power supplies connected to the rack assembly before installing or removing the CPU module. Working on a live system poses severe risks of electrical shock, controller backplane damage, or unexpected industrial machinery actuation.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003col style=\"list-style: none; padding-left: 0; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eEnsure the power supply unit (PSU) mounted to the C200H backplane is fully de-energized and wait for all status indicators to turn off completely.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eAlign the CPU module's upper and lower mounting hooks with the corresponding slot guides on the backplane.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eCarefully press the module inward until the multi-pin connector on the rear of the CPU seats firmly and completely into the backplane bus socket.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan style=\"color: #2d3748;\"\u003eLock the upper and lower retaining clips to prevent vibration-induced connection failure. Reapply power and verify that the 'RUN' LED illuminates status.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077932114283,"sku":"C200HS-CPU01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/C200HS-CPU01-x3anmltoqb1.png?v=1775733462","url":"https:\/\/www.plcprotech.com\/de\/products\/omron-c200hs-cpu01-sysmac-c200hs-series-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}