{"product_id":"omron-drt1-ad04-devicenet-analog-input-module","title":"Omron DRT1-AD04 DeviceNet Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for seamless integration into industrial automation networks, the \u003cstrong\u003eDRT1-AD04\u003c\/strong\u003e serves as a high-performance slice I\/O module for standard DeviceNet networks. This \u003cstrong\u003eanalog input module\u003c\/strong\u003e converts analog process signals from field sensors into digital data for real-time monitoring and control. It supports multiple voltage and current input ranges, allowing for highly flexible system designs across a variety of manufacturing and process control applications.\u003c\/p\u003e\n\n\u003cp\u003eThe unit features galvanically isolated circuitry to protect sensitive master controllers from field-side electrical noise. Its compact footprint supports both direct panel mounting and DIN rail installation, making it well-suited for high-density control cabinets.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFour independent, configurable analog input channels.\u003c\/li\u003e\n  \u003cli\u003eSupports multiple input ranges including standard industrial voltage and current ranges.\u003c\/li\u003e\n  \u003cli\u003eDual-mounting support for 35-mm DIN rail or direct screw mounting.\u003c\/li\u003e\n  \u003cli\u003eRobust isolation between internal circuitry and external communications.\u003c\/li\u003e\n  \u003cli\u003eFast internal conversion time with selectable active channels to optimize throughput.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFactory automation and process control systems.\u003c\/li\u003e\n  \u003cli\u003eRemote telemetry and environmental monitoring systems.\u003c\/li\u003e\n  \u003cli\u003eMachine tool monitoring and CNC integration.\u003c\/li\u003e\n  \u003cli\u003ePumping stations and chemical dosing applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOmron\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDRT1-AD04\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Points\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVoltage Input Ranges\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 5 V, 1 to 5 V, 0 to 10 V, -10 to 10 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Input Ranges\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 20 mA, 4 to 20 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Signal Input (Voltage)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e+\/-15 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Signal Input (Current)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e+\/-30 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Impedance (Voltage)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 MOhm minimum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Impedance (Current)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApprox. 250 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1\/6,000 (full scale)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Accuracy (Voltage, 25 degC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e+\/-0.3% FS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Accuracy (Voltage, 0 to 55 degC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e+\/-0.6% FS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Accuracy (Current, 25 degC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e+\/-0.4% FS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Accuracy (Current, 0 to 55 degC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e+\/-0.8% FS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConversion Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 ms\/point (8 ms for 4 channels, 4 ms for 2 channels)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20 MOhm minimum at 250 VDC (between insulated circuits)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommunications Power Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11 to 25 VDC (supplied via DeviceNet network)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInternal Power Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20.4 to 26.4 VDC (24 VDC +10% \/ -15%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM4 screw mounting or 35-mm DIN rail mounting\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Ambient Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e35% to 85% RH (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.160 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eWhen installing the module, ensure that the DeviceNet communications cable is routed away from high-voltage motor lines or power cables to prevent electromagnetic interference. Secure the module to either a 35-mm DIN rail or a panel plate using M4 screws, maintaining a clean and dust-free environment. Provide adequate ventilation clearance around the chassis to prevent thermal buildup within the enclosure.\u003c\/p\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077926084971,"sku":"DRT1-AD04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/drt1-ad04-ueejxwmlx2f.png?v=1775733714","url":"https:\/\/www.plcprotech.com\/de\/products\/omron-drt1-ad04-devicenet-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}