{"product_id":"omron-nj101-1000-sysmac-nj1-cpu-with-database-connectivity","title":"Omron NJ101-1000 Sysmac NJ1 CPU with Database Connectivity","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for seamless integration within the Sysmac automation platform, the \u003cstrong\u003eNJ101-1000\u003c\/strong\u003e central processing unit delivers efficient sequence and motion control combined with direct database connectivity. This controller enables high-speed data exchange directly between shop floor operations and enterprise SQL databases, eliminating the need for intermediate middleware, gateway PCs, or complex script writing.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eNJ101-1000\u003c\/strong\u003e supports synchronized motion control for up to 2 axes and accommodates up to 6 axes in total, including virtual axes. Built-in communication interfaces include EtherCAT and EtherNet\/IP, providing a robust backbone for modern industrial networks. Additionally, compatibility with the CJ I\/O bus allows for extensive local system expansion, making it highly versatile for retrofits and new installations alike.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect connection to SQL databases including Microsoft SQL Server, Oracle, MySQL, PostgreSQL, and Firebird.\u003c\/li\u003e\n  \u003cli\u003eIntegrated sequence and motion control execution in a single controller.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in EtherCAT master port for high-speed, synchronized machine network control.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in EtherNet\/IP port for standard factory network communications and data sharing.\u003c\/li\u003e\n  \u003cli\u003eCJ-series expansion bus support to preserve legacy I\/O infrastructure and enable modular scalability.\u003c\/li\u003e\n  \u003cli\u003eHigh-speed processing with a primary task cycle time of 1 ms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eReal-time quality traceability and recipe management in food and beverage packaging.\u003c\/li\u003e\n  \u003cli\u003eData logging and predictive maintenance analytics in automotive assembly lines.\u003c\/li\u003e\n  \u003cli\u003eHigh-precision motion synchronization in material handling and sorting systems.\u003c\/li\u003e\n  \u003cli\u003eDirect manufacturing execution system (MES) integration in pharmaceutical production.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOmron\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\/Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNJ101-1000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSysmac NJ1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eController Functionality\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMotion control, Sequence control, Database connectivity\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Number of Synchronous Axes\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Number of Axes (including virtual)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePrimary Task Cycle Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVariables Memory\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 MB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBuilt-in Ports\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEtherCAT Master, EtherNet\/IP, USB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eI\/O System Support\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCJ I\/O Bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Remote I\/O Nodes\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e64\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Expansion Units\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e40\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e90 mm x 90 mm x 90 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Type\u003c\/th\u003e\n      \u003cth\u003eConnector \/ Bus Type\u003c\/th\u003e\n      \u003cth\u003eFunctional Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEtherCAT Master\u003c\/td\u003e\n      \u003ctd\u003eRJ45\u003c\/td\u003e\n      \u003ctd\u003eConnects to servo drives, frequency inverters, and remote I\/O terminals.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEtherNet\/IP\u003c\/td\u003e\n      \u003ctd\u003eRJ45\u003c\/td\u003e\n      \u003ctd\u003eFacilitates connection to HMI, host computers, and database servers.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePeripheral Port\u003c\/td\u003e\n      \u003ctd\u003eUSB Type-B\u003c\/td\u003e\n      \u003ctd\u003eProvides a direct connection for Sysmac Studio programming software.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eI\/O Expansion Bus\u003c\/td\u003e\n      \u003ctd\u003eCJ Bus Connector\u003c\/td\u003e\n      \u003ctd\u003eEnables local expansion via compatible CJ-series I\/O modules.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eWhen installing the \u003cstrong\u003eNJ101-1000\u003c\/strong\u003e, ensure the CPU is mounted securely onto a standard DIN rail. To maintain proper operating temperatures, provide at least 20 mm of clearance above and below the unit for convection cooling. Ensure that the system grounding is connected directly to a dedicated ground point using a cable with a minimum cross-section of 2 mm squared. Shielded cables must be utilized for all industrial Ethernet connections (EtherCAT and EtherNet\/IP) to prevent electromagnetic interference in high-noise environments.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Compliant\u003c\/li\u003e\n  \u003cli\u003ecULus Listed\u003c\/li\u003e\n  \u003cli\u003eKC (Korean Communications Commission)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077900558699,"sku":"NJ101-1000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/nj101-1000-d1qjuidl2ch.png?v=1775733880","url":"https:\/\/www.plcprotech.com\/de\/products\/omron-nj101-1000-sysmac-nj1-cpu-with-database-connectivity","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}