{"product_id":"omron-nj101-1020-sysmac-nj1-cpu-module","title":"Omron NJ101-1020 Sysmac NJ1 CPU Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned to bridge the gap between machine control and IT database systems, the \u003cstrong\u003eOmron NJ101-1020\u003c\/strong\u003e provides integrated sequence, motion, and SQL database connectivity within a single Sysmac platform controller. By executing SQL instructions directly to databases such as Microsoft SQL Server, Oracle, and MySQL, this controller eliminates the need for intermediate gateway PCs or complex middleware. Built-in \u003cstrong\u003eEtherCAT\u003c\/strong\u003e and \u003cstrong\u003eEtherNet\/IP\u003c\/strong\u003e ports provide high-speed synchronization for up to 2 physical motion axes, making it a reliable choice for edge-to-cloud manufacturing architectures.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eDirect SQL Client functionality allowing real-time data logging, recipe downloads, and transactional synchronization with major database engines.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eSynchronized control for up to 2 physical motion axes and up to 6 total axes (including virtual axes).\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eDual integrated industrial Ethernet ports, separating machine-level deterministic EtherCAT communication from factory-level EtherNet\/IP communications.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eSpooling function to secure database records locally on an SD card during network connection interruptions.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eCompatible with standard CJ-Series high-speed I\/O units via expansion racks, preserving existing hardware investments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eFDA-compliant pharmaceutical packaging systems requiring per-cycle logging of batch and serialization parameters.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eAutomotive assembly lines utilizing database-driven recipe selection for mixed-model production runs.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eQuality control test stands directly writing performance curves and torque metrics to SQL servers.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eTraceability systems in food and beverage processing linking process variables with packaging barcodes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eModel Number\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNJ101-1020\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eSeries\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSysmac NJ1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eControl Functionality\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSequence Control, Motion Control, Database Connection (SQL Client)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eMax. Synchronous Motion Axes\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2 axes\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eMax. Total Axes (incl. Virtual)\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e6 axes\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePrimary Task Cycle Time\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eVariables Memory\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0.5 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eProgram Memory\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eBuilt-in Communication Ports\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eEtherCAT Master (RJ45), EtherNet\/IP (RJ45), USB 2.0 (Type-B)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eSupported Databases\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eOracle Database, Microsoft SQL Server, MySQL, PostgreSQL, IBM DB2, Firebird\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eMax. Remote I\/O Nodes\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e64 EtherCAT nodes\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eExpansion Unit Interface\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCJ I\/O Bus (up to 40 expansion units)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOperating Temperature\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0 to 55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eStorage Temperature\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-25 to 70 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePackage Dimensions (Calculated)\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e9.0 x 9.0 x 9.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eShipping Weight (Calculated)\u003c\/th\u003e\n        \u003ctd style=\"padding: 1.2 kg;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eInterface Port\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eFunction \/ Connection Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eEtherNet\/IP Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRJ45 connection. Used for database communication, Sysmac Studio tool connection, HMI monitoring, and inter-controller tag data links.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eEtherCAT Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRJ45 connection. Serves as the EtherCAT master port. Integrates motion drives, safety components, and remote NX\/GX I\/O terminals.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eUSB Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUSB 2.0 Type-B connector. Local programming, configuration interface, and diagnostics link.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0; font-weight: bold;\"\u003eSD Card Slot\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAccepts industrial SD\/SDHC cards for database spooling buffer, program backup, and user-defined data logging.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe NJ101-1020 has integrated database connectivity licenses embedded directly in its firmware. Unlike the standard NJ101-1000, which requires external software links or PC gateways for database interaction, this unit can connect natively. For high-count multi-axis synchronization above 2 axes, users should consider the NJ301 or NJ501 series platforms, which maintain identical programming environments via Sysmac Studio.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo protect your processes from server failures or local corporate network outages, configure the SQL database spooling feature inside Sysmac Studio. This prevents loss of critical traceability data during network drops. Ensure you calculate SD card write cycle lifespans when logging high-frequency cycles; always use industrial-grade Omron HMC-SD memory cards to prevent unexpected block degradation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eKeep the dedicated industrial EtherCAT networks completely physical isolated from the standard factory office network connected via EtherNet\/IP. Cross-routing office traffic into the EtherCAT segment will cause master timing jitters, leading to packet loss and axis synchronization faults. Use shielded twisted-pair (STP) Cat5e or Cat6 cables with double shielding (aluminum tape and braided shield) for all EtherCAT lines.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.75rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate and lock out all external 24V DC power systems before mounting, dismounting, or wiring the CPU module. Running wire runs or installing modules while the system is hot can cause destructive electrical transients on the internal CJ I\/O backplane bus, leading to permanent component damage or CPU failure.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; height: 28px; font-weight: bold; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eMount the CPU module securely to a clean, well-grounded 35 mm DIN rail inside a protective NEMA or IP54-rated industrial control panel.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; height: 28px; font-weight: bold; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eEnsure the terminal block connection to the power supply unit matches the defined ground terminal block connection, verifying resistance is below 100 ohms.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; height: 28px; font-weight: bold; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eFirmly lock the slide connectors of adjacent expansion CJ-Series units to ensure the continuous backplane data bus is mechanically and electrically locked.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 28px; height: 28px; font-weight: bold; margin-right: 0.75rem;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003ePower on the controller and use the Sysmac Studio platform to download the required database configuration, verification credentials, and user program.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077912322411,"sku":"NJ101-1020","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/nj101-1020-pqsjm0pmtph.png?v=1775733881","url":"https:\/\/www.plcprotech.com\/de\/products\/omron-nj101-1020-sysmac-nj1-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}