{"product_id":"omron-nx-ts3101-nx-series-temperature-input-unit","title":"Omron NX-TS3101 NX Series Temperature Input Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for high-accuracy thermal monitoring within Sysmac automation architectures, the \u003cstrong\u003eOmron NX-TS3101\u003c\/strong\u003e functions as a high-density, multi-channel \u003cstrong\u003etemperature input unit\u003c\/strong\u003e. This module supports up to four thermocouple sensor connections, utilizing high-resolution conversions to deliver stable temperature readings in demanding industrial environments. Operating within the modular NX-series I\/O system, it integrates seamlessly with Sysmac NJ\/NX controllers or remote communication coupler units.\u003c\/p\u003e\n\n\u003cp\u003eThe unit features a specialized internal design with independent channel isolation, preventing signal interference and ground loops. Real-time temperature acquisition is managed via Free-Run refreshing, optimizing performance for thermal processes such as extrusion, heat treating, and environmental chambers. For quick wiring and maintenance, the physical interface is built with dual screwless clamping terminal blocks, minimizing installation labor and ensuring vibration-proof connections.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFour thermocouple input channels supporting multiple sensor types (K, J, T, E, L, U, N, R, S, B, WRe5-26, PLII).\u003c\/li\u003e\n  \u003cli\u003eFast conversion rate of 250 ms per Unit for responsive control loops.\u003c\/li\u003e\n  \u003cli\u003eComprehensive electrical isolation between inputs and the internal NX bus, and between channels.\u003c\/li\u003e\n  \u003cli\u003eDual 16-point screwless clamping terminal blocks for secure, tool-free field wiring.\u003c\/li\u003e\n  \u003cli\u003eDirect integration with Omron CPU Units, Communication Control Units, or EtherCAT\/EtherNet\/IP Communication Couplers.\u003c\/li\u003e\n  \u003cli\u003eStatus indication via onboard TS indicator.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePlastic extrusion and injection molding machines.\u003c\/li\u003e\n  \u003cli\u003eIndustrial ovens, furnaces, and thermal treatment chambers.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery requiring precise heat sealing.\u003c\/li\u003e\n  \u003cli\u003eHVAC and environmental control systems.\u003c\/li\u003e\n  \u003cli\u003eBoiler and steam generation plant monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOmron\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNX-TS3101\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNX I\/O Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTemperature Input Unit (Thermocouple)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Input Points\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 points\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupported Temperature Sensors\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eK, J, T, E, L, U, N, R, S, B, WRe5-26, PLII\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConversion Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e250 ms per Unit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.1 degC max. (0.2 degC max. for R, S, or W input types)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eI\/O Refreshing Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFree-Run refreshing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eExternal Connection Terminals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrewless clamping terminal block (16 terminals x 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Conversion Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e+\/-20 degC of the nominal sensor input range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAbsolute Maximum Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e+\/-130 mV\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20 kOhm min.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Disconnection Detection Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApprox. 0.1 uA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWarm-up Period\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e30 minutes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIsolation Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePower: Transformer isolation, Signal: Photocoupler isolation (Input to NX bus and Channel-to-Channel)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20 MOhm min. between isolated circuits (at 100 VDC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e510 VAC between isolated circuits for 1 minute (leakage current 5 mA max.)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Consumption (CPU\/Comm Control Unit)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.75 W max.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Consumption (Comm Coupler Unit)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.30 W max.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 mm x 100 mm x 71 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the unit onto standard 35 mm DIN rail. Ensure the lock levers click into place to guarantee physical stability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the DIN rail is grounded to functional ground to maintain proper noise immunity for low-voltage sensor lines.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Insert solid wires or ferruled stranded wires directly into the screwless clamping terminal block. For raw stranded wire, use a flat-blade screwdriver to depress the orange release button while inserting.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarm-up:\u003c\/strong\u003e Allow the system to run for a minimum of 30 minutes after power-on to satisfy thermal stabilization requirements before taking critical process measurements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Use shielded compensation cables for all thermocouple lines, and terminate shields at the system's designated grounding point.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077906489707,"sku":"NX-TS3101","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/nx-ts3101-tsfnwmbov3k.png?v=1775734024","url":"https:\/\/www.plcprotech.com\/de\/products\/omron-nx-ts3101-nx-series-temperature-input-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}