{"product_id":"schneider-atv212hd11m3x-altivar-212-variable-frequency-drive","title":"Schneider ATV212HD11M3X Altivar 212 Variable Frequency Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eATV212HD11M3X\u003c\/strong\u003e is a \u003cstrong\u003evariable frequency drive\u003c\/strong\u003e (VFD) from the \u003cstrong\u003eAltivar 212\u003c\/strong\u003e series, specifically engineered for HVAC applications. Rated for 11 kW at 240 V, this \u003cstrong\u003efrequency controller\u003c\/strong\u003e manages motor speed and torque with high efficiency to optimize energy consumption in pump, fan, and compressor systems. This unit is configured for 3-phase supply without an integrated EMC filter and is housed in an IP21-rated enclosure, providing reliable motor control for industrial and commercial building automation.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e11 kW power rating for medium-duty motor applications.\u003c\/li\u003e\n\u003cli\u003eOptimized specifically for HVAC-related drive functions.\u003c\/li\u003e\n\u003cli\u003eIP21 enclosure rating for protection against solid objects.\u003c\/li\u003e\n\u003cli\u003e3-phase operation for balanced power distribution.\u003c\/li\u003e\n\u003cli\u003eRobust control algorithms for energy-efficient motor management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal pumps and fan control.\u003c\/li\u003e\n\u003cli\u003eHVAC system air handling units.\u003c\/li\u003e\n\u003cli\u003eCooling tower fan motor regulation.\u003c\/li\u003e\n\u003cli\u003eIndustrial process circulation systems.\u003c\/li\u003e\n\u003cli\u003eCommercial building climate control integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAltivar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubrange\u003c\/td\u003e\n\u003ctd\u003e212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVariable Frequency Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhases\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e11.07 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e39 x 29 x 28 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85044095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the \u003cstrong\u003eATV212HD11M3X\u003c\/strong\u003e in a vertical position within a ventilated cabinet to ensure proper heat dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Maintain adequate spacing around the drive to allow for airflow, as specified in the official installation manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Ensure power input and motor output cables are sized correctly for the 11 kW load; use shielded motor cables to mitigate potential electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the drive chassis to a solid earth ground point to ensure safety and operational stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Perform initial parameter settings via the integrated keypad or communication interface to match motor nameplate data.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104572203371,"sku":"ATV212HD11M3X","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/atv212hd11m3x-xui323eogdz.png?v=1776162177","url":"https:\/\/www.plcprotech.com\/de\/products\/schneider-atv212hd11m3x-altivar-212-variable-frequency-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}