{"product_id":"schneider-electric-ats48d62y-altistart-48-soft-starter","title":"Schneider Electric ATS48D62Y Altistart 48 Sanftanlasser","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eATS48D62Y\u003c\/strong\u003e is an \u003cstrong\u003eAltistart 48\u003c\/strong\u003e series \u003cstrong\u003esoft starter\u003c\/strong\u003e engineered for the controlled starting and stopping of three-phase asynchronous motors. Designed to handle a rated current of 52 A and supply voltages ranging from 208 V to 690 V, this device supports motors with power ratings between 11 kW and 45 kW. By managing the torque profile during motor acceleration and deceleration, the \u003cstrong\u003eATS48D62Y\u003c\/strong\u003e reduces mechanical stress on connected equipment and minimizes electrical peak loads during start-up. This unit is a critical component for industrial systems requiring enhanced motor protection and improved operational longevity.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptimized for asynchronous motor soft start and soft stop applications\u003c\/li\u003e\n\u003cli\u003eSupports a wide supply voltage range of 208–690 V\u003c\/li\u003e\n\u003cli\u003eRated operational current of 52 A\u003c\/li\u003e\n\u003cli\u003eAdjustable power handling capacity from 11 kW to 45 kW\u003c\/li\u003e\n\u003cli\u003eDesigned to minimize mechanical wear and electrical stress on motor systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentrifugal and piston pumps\u003c\/li\u003e\n\u003cli\u003eFans and blowers\u003c\/li\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eConveyor systems\u003c\/li\u003e\n\u003cli\u003eGeneral industrial motor-driven machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eAltistart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubrange\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSoft starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e52 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e11–45 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e208–690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e40.00 cm x 36.50 cm x 30.50 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e84798997\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the soft starter in a vertical orientation to facilitate proper cooling airflow through the internal heatsinks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Maintain minimum required spacing above and below the unit as defined by the installation manual to ensure effective heat dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the ambient temperature and humidity levels remain within the limits specified for the \u003cstrong\u003eAltistart 48\u003c\/strong\u003e range to prevent thermal derating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use appropriately rated power cabling for the motor and supply connections; ensure all terminals are tightened to the specified torque.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Integrate external motor overload protection and short-circuit protection devices as required by local electrical codes and the specific application design.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104559751531,"sku":"ATS48D62Y","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ats48d62y-zztfcjwa5ko.png?v=1776162123","url":"https:\/\/www.plcprotech.com\/de\/products\/schneider-electric-ats48d62y-altistart-48-soft-starter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}