{"product_id":"schneider-electric-bmep584040-modicon-m580-processor-module","title":"Schneider Electric BMEP584040 Modicon M580 Processor Module","description":"\u003ch1\u003eSchneider Electric BMEP584040 Modicon M580 Processor Module\u003c\/h1\u003e\n\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eTo manage complex industrial architectures, the \u003cstrong\u003eBMEP584040\u003c\/strong\u003e serves as a high-performance \u003cstrong\u003eprocessor module\u003c\/strong\u003e within the Schneider Electric Modicon M580 automation platform. This Level 4 controller is engineered to support both distributed and remote I\/O structures, providing robust processing capabilities for demanding control applications. Operating on an Ethernet-based backbone, it facilitates seamless communication across plant networks, ensuring high-speed data transmission, system interoperability, and consistent performance in harsh industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSupports Level 4 distributed and remote I\/O network architectures.\u003c\/li\u003e\n  \u003cli\u003eNative Ethernet connectivity integrated directly into the backplane for rapid data exchange.\u003c\/li\u003e\n  \u003cli\u003eHigh-capacity memory allocation designed for complex application programs, variables, and data logging.\u003c\/li\u003e\n  \u003cli\u003eSeamless integration with Schneider Electric EcoStruxure Control Expert programming software.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in diagnostics and cybersecurity features to protect industrial control operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eWater and wastewater treatment facilities.\u003c\/li\u003e\n  \u003cli\u003eOil and gas processing and distribution.\u003c\/li\u003e\n  \u003cli\u003ePower generation and utility automation.\u003c\/li\u003e\n  \u003cli\u003eMining, minerals, and metals processing.\u003c\/li\u003e\n  \u003cli\u003eFood and beverage manufacturing lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSchneider Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBMEP584040\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eModicon M580\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eProcessor Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePerformance Level\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLevel 4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eI\/O Architecture Support\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDistributed I\/O and Remote I\/O\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.87 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (Packaging)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.0 cm x 17.3 cm x 8.8 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85044095\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure the rack power supply is completely switched off before inserting or removing the processor module.\u003c\/li\u003e\n  \u003cli\u003eMount the module securely onto a compatible Modicon M580 Ethernet backplane.\u003c\/li\u003e\n  \u003cli\u003eTighten the module mounting screws to the specified torque to ensure proper grounding and resistance to mechanical vibration.\u003c\/li\u003e\n  \u003cli\u003eMaintain the recommended ventilation clearances around the rack assembly as specified in the hardware installation manual.\u003c\/li\u003e\n  \u003cli\u003eUse shielded Ethernet cabling for all network connections to minimize electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104502243691,"sku":"BMEP584040","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bmep584040-cbwp4yemcug.png?v=1776162856","url":"https:\/\/www.plcprotech.com\/de\/products\/schneider-electric-bmep584040-modicon-m580-processor-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}