{"product_id":"schneider-modicon-quantum-140ddm39000-mixed-i-o-module","title":"Schneider Modicon Quantum 140DDM39000 Misch-Ein-\/Ausgangsmodul","description":"\u003cp\u003eThe \u003cstrong\u003e140DDM39000\u003c\/strong\u003e is a \u003cstrong\u003emixed input\/output module\u003c\/strong\u003e for the \u003cstrong\u003eModicon Quantum\u003c\/strong\u003e automation platform. This high-density module provides a combination of 16 discrete digital inputs rated for 24V DC and 8 discrete digital outputs rated for 24V DC, with a 2A switching capacity per output channel. It is designed to provide efficient space utilization within the Quantum backplane, consolidating both input and output functions into a single module slot.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMixed I\/O configuration: 16 Inputs and 8 Outputs\u003c\/li\u003e\n\u003cli\u003eInput voltage rating: 24V DC\u003c\/li\u003e\n\u003cli\u003eOutput rating: 24V DC, 2A per channel\u003c\/li\u003e\n\u003cli\u003eDesigned for high-performance Modicon Quantum control systems\u003c\/li\u003e\n\u003cli\u003eCompact footprint for high-density I\/O configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated control of sensors and actuators in industrial machinery\u003c\/li\u003e\n\u003cli\u003eMachine-level automation requiring localized discrete control\u003c\/li\u003e\n\u003cli\u003eCompact process control cabinets\u003c\/li\u003e\n\u003cli\u003eMaintenance and expansion of legacy Quantum PLC architectures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMixed I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e16 (24V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e8 (24V DC, 2A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e16.50 x 31.50 x 5.00 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.96 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExport Control (ECCN)\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Always de-energize the Quantum rack before module insertion. Align the module with the backplane connectors and ensure the locking mechanism is fully secured to prevent signal discontinuity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Utilize appropriate gauge wiring for the 2A output capacity to prevent overheating. Ensure that input and output circuits are clearly labeled and separated to prevent noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Proper grounding to the chassis PE (Protective Earth) is essential for EMI\/RFI immunity, especially in environments with high motor noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Protection:\u003c\/strong\u003e Given the 2A output capacity, ensure external inductive loads (such as solenoids or relays) are equipped with appropriate suppression (e.g., flyback diodes) to protect the module's switching transistors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Install in an environment free from conductive dust and excessive moisture to maintain the integrity of the terminal connections and internal electronics.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104563421547,"sku":"140DDM39000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/140ddm39000-in5fr15uo0e.png?v=1776159599","url":"https:\/\/www.plcprotech.com\/de\/products\/schneider-modicon-quantum-140ddm39000-mixed-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}