{"product_id":"schneider-tesys-d-lx1d4v7-contactor-coil","title":"Schneider TeSys D LX1D4V7 Schützspule","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eLX1D4V7\u003c\/strong\u003e is a replacement \u003cstrong\u003eContactor Coil\u003c\/strong\u003e from the \u003cstrong\u003eTeSys D\u003c\/strong\u003e range, engineered by \u003cstrong\u003eSchneider Electric\u003c\/strong\u003e to ensure the precise operation of industrial contactors. Designed for compatibility with specific TeSys D25 and D32 series units, this coil facilitates reliable electromagnetic actuation within electrical control circuits. It is rated for an operational voltage of 400 V and supports both 50 Hz and 60 Hz frequencies, providing consistent performance across various global power standards.\u003c\/p\u003e\n\u003cp\u003eThis component is built to meet the rigorous demands of industrial automation, offering high durability and reliable switching capabilities. As a genuine Schneider Electric spare part manufactured in France, it is an essential maintenance component for users seeking to restore or maintain the operational integrity of their existing TeSys D contactor configurations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with TeSys D25\/32 series contactors\u003c\/li\u003e\n\u003cli\u003eOperational voltage of 400 V AC\u003c\/li\u003e\n\u003cli\u003eDual-frequency support (50\/60 Hz)\u003c\/li\u003e\n\u003cli\u003eRobust design for reliable electromagnetic performance\u003c\/li\u003e\n\u003cli\u003eManufactured to strict industrial standards for high durability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial motor control circuits\u003c\/li\u003e\n\u003cli\u003eAutomation and control panel maintenance\u003c\/li\u003e\n\u003cli\u003eReplacement component for TeSys D-line contactors\u003c\/li\u003e\n\u003cli\u003eHVAC and lighting control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eContactor Coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Voltage\u003c\/td\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eD25\/32 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Phase\u003c\/td\u003e\n\u003ctd\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommodity Code\u003c\/td\u003e\n\u003ctd\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Ensure all power to the contactor is disconnected and locked out before attempting to remove or install the coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Verify that the coil voltage rating matches your control circuit voltage exactly to prevent coil burnout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembly:\u003c\/strong\u003e Carefully remove the top housing of the contactor to access the existing coil. Slide the old coil out and replace it with the new \u003cstrong\u003eLX1D4V7\u003c\/strong\u003e, ensuring the magnetic core is properly seated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTesting:\u003c\/strong\u003e After installation, verify the movement of the contactor armature and perform a functional test before applying full power to the main circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the contactor enclosure remains clean and free of conductive debris to maintain the insulation integrity of the coil.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":53104561750379,"sku":"LX1D4V7","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/lx1d4v7-zpfssagqgi5.png?v=1776163276","url":"https:\/\/www.plcprotech.com\/de\/products\/schneider-tesys-d-lx1d4v7-contactor-coil","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}