{"product_id":"siemens-6av3617-1jc20-0ax0-simatic-hmi-op17-operator-panel","title":"Siemens 6AV3617-1JC20-0AX0 SIMATIC HMI OP17 Operator Panel","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe 6AV3617-1JC20-0AX0 is an operator panel from the Siemens SIMATIC HMI OP17 series, designed for machine-level monitoring and control. This unit features a monochrome \u003cstrong\u003eLC display\u003c\/strong\u003e with \u003cstrong\u003eLED backlighting\u003c\/strong\u003e, offering a clear text-based interface configurable for either \u003cstrong\u003e4x20 or 8x40 characters\u003c\/strong\u003e. It is engineered for integration with legacy \u003cstrong\u003eSIMATIC S7\u003c\/strong\u003e and M7 automation systems via its \u003cstrong\u003ePROFIBUS-DP\u003c\/strong\u003e interface, which supports communication speeds up to \u003cstrong\u003e1.5 Mbaud\u003c\/strong\u003e. The panel operates on a standard 24V DC supply and provides operator input through its integrated keypad. Please note, this specific model is not UL\/CSA-listed.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003eMonochrome Liquid Crystal Display (LC) with LED illumination\u003c\/li\u003e\n  \u003cli\u003eConfigurable text display format: 4 lines x 20 characters or 8 lines x 40 characters\u003c\/li\u003e\n  \u003cli\u003eIntegrated keypad for direct operator interaction and data entry\u003c\/li\u003e\n  \u003cli\u003eSupports PROFIBUS-DP communication protocol at up to 1.5 Mbaud\u003c\/li\u003e\n  \u003cli\u003eDesigned for direct compatibility with SIMATIC S7 and M7 controllers\u003c\/li\u003e\n  \u003cli\u003eIncludes 256 kbyte of user memory for application data\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; color: #2d3748;\"\u003e\n  \u003cli\u003eLegacy machine control and process visualization\u003c\/li\u003e\n  \u003cli\u003eSmall to medium-sized automation systems\u003c\/li\u003e\n  \u003cli\u003eProduction line monitoring and diagnostics\u003c\/li\u003e\n  \u003cli\u003eSpare part replacement in existing SIMATIC S7\/M7 installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-bottom: 16px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; background-color: #f7fafc; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eBrand\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSIMATIC HMI OP17\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6AV3617-1JC20-0AX0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eOperator Panel\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e24V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eDisplay Type\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eLC (Liquid Crystal)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eBacklighting\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eLED\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eColor Display\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eNo (Monochrome, 2 colors)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eDisplay Format\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e4x20 or 8x40 characters\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eOperator Input\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eKeys\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eUser Memory\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e256 kbyte\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCommunication Protocol\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePROFIBUS-DP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCommunication Speed\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e1.5 Mbaud\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eController Compatibility\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSIMATIC S7, M7\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eApprovals\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eNot UL\/CSA Listed\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eProduct Lifecycle\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eSuccessor Part\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e6AV3617-1JC20-0AX1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e1.10 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e25.0 cm x 28.7 cm x 8.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eEAR99\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 8px; margin-top: 24px; margin-bottom: 16px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Hazardous voltages may be present. All installation and maintenance procedures must be performed by qualified personnel with the main electrical supply de-energized and locked out (LOTO). Failure to comply can result in severe injury or death.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; justify-content: center; align-items: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003ePrepare Enclosure:\u003c\/strong\u003e Verify that the panel cutout dimensions in the enclosure match the HMI's mounting requirements. Ensure the mounting surface is clean, flat, and free of debris to guarantee a proper seal.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; justify-content: center; align-items: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eMount the Unit:\u003c\/strong\u003e Insert the operator panel into the cutout from the front of the enclosure. Secure it from the rear using the provided mounting clamps, tightening them evenly to the manufacturer's specified torque to ensure environmental sealing.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; justify-content: center; align-items: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eConnect Power:\u003c\/strong\u003e Connect a stable, correctly fused 24V DC power source to the designated power terminals on the rear of the unit. Verify correct polarity before energizing.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; justify-content: center; align-items: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eEstablish Communication:\u003c\/strong\u003e Terminate the PROFIBUS-DP cable at the HMI's communication port. Ensure proper shielding, grounding, and termination resistance is applied as required by the network topology.\u003c\/span\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #fff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; justify-content: center; align-items: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cspan\u003e\u003cstrong\u003eFinal Checks:\u003c\/strong\u003e Once all connections are secure, remove the lockout\/tagout devices and energize the control panel. Verify the HMI powers on and establishes communication with the controller before closing the enclosure door.\u003c\/span\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716787040619,"sku":"6AV3617-1JC20-0AX0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av3617-1jc20-0ax0-jtfghmkkvmp_6fc78e2b-5fd5-4879-9dc9-cd45a7deb5e2.jpg?v=1767089782","url":"https:\/\/www.plcprotech.com\/de\/products\/siemens-6av3617-1jc20-0ax0-simatic-hmi-op17-operator-panel","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}