{"product_id":"siemens-6av7611-0ae10-0bh0-simatic-panel-pc-670-panel-pc","title":"Siemens 6AV7611-0AE10-0BH0 SIMATIC Panel PC 670 Panel PC","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe Siemens \u003cstrong\u003e6AV7611-0AE10-0BH0\u003c\/strong\u003e is a \u003cstrong\u003eSIMATIC Panel PC 670\u003c\/strong\u003e designed for industrial applications requiring a robust human-machine interface and computing platform. This panel PC features a \u003cstrong\u003e10-inch TFT display\u003c\/strong\u003e, a \u003cstrong\u003eCeleron 300 MHz CPU\u003c\/strong\u003e, \u003cstrong\u003e64 MB of RAM\u003c\/strong\u003e, and a \u003cstrong\u003e40 GB hard drive\u003c\/strong\u003e. It comes pre-configured with \u003cstrong\u003eWindows NT 4.0 German\u003c\/strong\u003e and supports a \u003cstrong\u003e115-230 V\u003c\/strong\u003e power input, typically supplied with a U.S. mains cable. The \u003cstrong\u003eSIMATIC Panel PC 670\u003c\/strong\u003e series provides a compact and integrated solution for visualization and control tasks in various industrial environments.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIntegrated 10-inch TFT Display\u003c\/li\u003e\n  \u003cli\u003eCeleron 300 MHz Processor\u003c\/li\u003e\n  \u003cli\u003e64 MB System RAM\u003c\/li\u003e\n  \u003cli\u003e40 GB Hard Disk Drive\u003c\/li\u003e\n  \u003cli\u003ePre-installed Windows NT 4.0 (German)\u003c\/li\u003e\n  \u003cli\u003eWide-range power input (115-230 V)\u003c\/li\u003e\n  \u003cli\u003eIndustrial-grade panel mounting design\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMachine control and visualization\u003c\/li\u003e\n  \u003cli\u003eProcess monitoring and data acquisition\u003c\/li\u003e\n  \u003cli\u003eOperator interface for automation systems\u003c\/li\u003e\n  \u003cli\u003eData logging and reporting in manufacturing\u003c\/li\u003e\n  \u003cli\u003eEmbedded control systems requiring a graphical interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n  \u003ctable border=\"1\" style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSimatic Panel PC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSubrange\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePC670\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eType of Product\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePanel PC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e10\" TFT Display\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCPU\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCeleron 300 MHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRAM\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e64 MBYTE\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHard Drive\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e40 GB HD\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating System\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWindows NT 4.0 German\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e115-230 V (U.S. Mains Cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Phase\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eObsolete\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4.00 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371091\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eN\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDe-energize System:\u003c\/strong\u003e Ensure all power to the installation area and connected equipment is completely de-energized and locked out before beginning installation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the panel PC into a prepared panel cutout using the appropriate mounting clamps or screws provided. Ensure a tight seal to maintain environmental protection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the 115-230 V AC power supply to the designated power input terminal. Verify correct voltage and polarity before applying power.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a proper protective earth (PE) connection to the designated grounding terminal on the panel PC chassis to ensure safety and minimize electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePeripheral Connections:\u003c\/strong\u003e Connect any required peripherals such as keyboards, mice, or external storage devices to the appropriate ports.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNetwork\/Communication:\u003c\/strong\u003e If applicable, connect Ethernet or other communication cables to the respective ports. Ensure proper cable routing to avoid strain and interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Startup:\u003c\/strong\u003e After all connections are secure, re-energize the system. Monitor the panel PC during startup for proper operation and display initialization.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52716404310379,"sku":"6AV7611-0AE10-0BH0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7611-0ae10-0bh0-waugswvkxwt_c8ec0b22-29e5-4306-a574-6ab97611b2b1.jpg?v=1767082208","url":"https:\/\/www.plcprotech.com\/de\/products\/siemens-6av7611-0ae10-0bh0-simatic-panel-pc-670-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}