{"product_id":"siemens-6av7613-0ab32-0cf0-simatic-panel-pc-670-panel-pc","title":"Siemens 6AV7613-0AB32-0CF0 SIMATIC Panel PC 670 Panel PC","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px; margin-top: 0;\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThis device is a Siemens 6AV7613-0AB32-0CF0 panel PC from the SIMATIC Panel PC 670 series. It is configured with a \u003cstrong\u003e12-inch TFT display\u003c\/strong\u003e, a \u003cstrong\u003ePentium III 500 MHz CPU\u003c\/strong\u003e, \u003cstrong\u003e256 MB of RAM\u003c\/strong\u003e, and a \u003cstrong\u003e20 GB hard drive\u003c\/strong\u003e with an integrated CD-ROM. This unit is designed for industrial human-machine interface (HMI) and control applications, operating on a 115-230 V AC power supply. It comes pre-installed with the Windows 98 operating system in English and includes a European mains cable. Please note that this product is considered obsolete, making it suitable for legacy system maintenance and spares.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eIntegrated 12-inch TFT color display for visualization.\u003c\/li\u003e\n  \u003cli\u003ePowered by a Pentium III 500 MHz processor.\u003c\/li\u003e\n  \u003cli\u003eEquipped with 256 MB of system RAM.\u003c\/li\u003e\n  \u003cli\u003eIncludes a 20 GB hard drive for local data storage.\u003c\/li\u003e\n  \u003cli\u003eFeatures an integrated CD-ROM drive.\u003c\/li\u003e\n  \u003cli\u003ePre-loaded with Microsoft Windows 98 (English version).\u003c\/li\u003e\n  \u003cli\u003eFlexible power input range of 115-230 V AC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; margin-left: 20px; padding-left: 10px;\"\u003e\n  \u003cli\u003eLegacy HMI (Human Machine Interface) replacement.\u003c\/li\u003e\n  \u003cli\u003eSupervisory Control and Data Acquisition (SCADA) nodes.\u003c\/li\u003e\n  \u003cli\u003eMachine-level data logging and visualization.\u003c\/li\u003e\n  \u003cli\u003eProcess control front-end for manufacturing lines.\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation control panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #ccc;\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth style=\"background-color: #f2f2f2; padding: 12px; border: 1px solid #ccc; text-align: left; color: #2d3748;\"\u003eSpecification\u003c\/th\u003e\n        \u003cth style=\"background-color: #f2f2f2; padding: 12px; border: 1px solid #ccc; text-align: left; color: #2d3748;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e6AV7613-0AB32-0CF0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSIMATIC Panel PC 670\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eDisplay\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e12-inch TFT\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProcessor (CPU)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePentium III 500 MHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eMemory (RAM)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e256 MB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eStorage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e20 GB Hard Drive, CD-ROM Drive\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eWindows 98 (English)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eInput Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e115-230 V AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eIncluded Accessories\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eEuropean Mains Cable\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e4.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eHarmonized Tariff Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eECCN\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eN (No License Required)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eGermany (Estimate)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSiemens\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e45 cm x 35 cm x 20 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2d3748; padding-bottom: 8px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 5px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #c53030;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Installation, commissioning, and maintenance must be performed by qualified, trained personnel only. De-energize all power sources and follow Lockout\/Tagout (LOTO) procedures before accessing terminals. Failure to comply can result in severe injury, death, or equipment damage.\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding-left: 0;\"\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003ePanel Cutout and Mounting:\u003c\/strong\u003e Prepare the control cabinet panel cutout according to the device's mechanical drawings. Ensure the mounting surface is clean, flat, and rigid. Insert the Panel PC into the cutout and secure it evenly using all provided mounting clamps to maintain the specified ingress protection rating.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eProtective Earth (PE) Connection:\u003c\/strong\u003e Connect the chassis to the control cabinet's protective earth system using a low-impedance conductor. This connection is critical for operator safety and electromagnetic compatibility (EMC). Use the designated grounding terminal on the device.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003ePower Supply Connection:\u003c\/strong\u003e Connect the AC mains power using the provided cable to a stable, correctly rated power source (115-230 V AC). Ensure the source is protected by an appropriate circuit breaker or fuse. Route power cables separately from signal and communication lines to minimize interference.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003ePeripheral and Network Connections:\u003c\/strong\u003e Connect all required peripherals (e.g., keyboard, mouse) and network cables. Use shielded cables for all data communication lines and ensure shields are properly terminated at one end to the cabinet ground to prevent ground loops.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-block; text-align: center; line-height: 24px; font-weight: bold; color: white; background-color: #2b6cb0; border-radius: 50%; width: 24px; height: 24px; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eSystem Power-Up:\u003c\/strong\u003e After verifying all connections are secure and correct, remove LOTO devices and re-energize the main power source. Power on the Panel PC and verify that the operating system boots correctly and all connected devices are recognized.\n    \u003c\/div\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715828740459,"sku":"6AV7613-0AB32-0CF0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7613-0ab32-0cf0-htugk1qe1ws_12384f4b-f5d5-45e7-bf25-acd57dd221d2.jpg?v=1767071990","url":"https:\/\/www.plcprotech.com\/de\/products\/siemens-6av7613-0ab32-0cf0-simatic-panel-pc-670-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}