{"product_id":"siemens-6av7872-0bb22-0ac0-simatic-panel-pc-677b","title":"Siemens 6AV7872-0BB22-0AC0 SIMATIC Panel PC 677B","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Siemens \u003cstrong\u003e6AV7872-0BB22-0AC0\u003c\/strong\u003e SIMATIC Panel PC 677B is a robust industrial computer engineered for demanding production environments. This model integrates a 15-inch touch display with a resolution of 1024 x 768, providing clear visualization and intuitive operation for various process control applications. The \u003cstrong\u003e6AV7872-0BB22-0AC0\u003c\/strong\u003e features dual 10\/100\/1000 Mbit\/s Ethernet interfaces, four USB V2.0 ports (including a front-accessible USB), and a serial (COM1) port, ensuring flexible connectivity for peripherals and data transfer. Internally, it is powered by an Intel Celeron M440 processor at 1.86 GHz, complemented by 1 GB DDR2 RAM and a RAID1 configuration with two 250 GB SATA (2.5\") hard drives for enhanced data security and reliability. Additional capabilities include PROFIBUS\/MP communication and 2 MB buffer SRAM. The unit is supplied with a 110\/230 V AC power supply unit with NAMUR and a European power cable, operating on Windows XP Professional MUI with multi-language support (DE, EN, FR, ES, IT, JA, ZH, KO). This Panel PC is well-suited for project managers and production leaders requiring a stable and efficient solution for process monitoring and control on the production floor, ensuring consistent performance, long-term availability, and compatibility with industrial standards.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e15-inch touch display with 1024 x 768 resolution\u003c\/li\u003e\n    \u003cli\u003eDual 10\/100\/1000 Mbit\/s Ethernet interfaces\u003c\/li\u003e\n    \u003cli\u003eFour USB V2.0 ports, including a front-accessible interface\u003c\/li\u003e\n    \u003cli\u003eOne serial (COM1) port\u003c\/li\u003e\n    \u003cli\u003eIntel Celeron M440 processor at 1.86 GHz\u003c\/li\u003e\n    \u003cli\u003e1 GB DDR2 RAM and 2 MB buffer SRAM\u003c\/li\u003e\n    \u003cli\u003eRAID1 configuration with two 250 GB SATA (2.5\") hard drives\u003c\/li\u003e\n    \u003cli\u003ePROFIBUS\/MP communication support\u003c\/li\u003e\n    \u003cli\u003eIntegrated 110\/230 V AC power supply unit with NAMUR\u003c\/li\u003e\n    \u003cli\u003ePre-installed Windows XP Professional MUI (Multi-User Interface)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eIndustrial process monitoring and control\u003c\/li\u003e\n    \u003cli\u003eOperator visualization and interaction in manufacturing environments\u003c\/li\u003e\n    \u003cli\u003eData acquisition and processing in automation systems\u003c\/li\u003e\n    \u003cli\u003eSystems requiring integrated industrial computing with PROFIBUS\/MP connectivity\u003c\/li\u003e\n    \u003cli\u003eHuman-Machine Interface (HMI) for machinery and plant control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n    \u003ctable style=\"width:100%; border-collapse: collapse; border: 1px solid #ddd;\"\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left; background-color: #f2f2f2;\"\u003eCategory\u003c\/th\u003e\n                \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left; background-color: #f2f2f2;\"\u003eSpecification\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRange\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSIMATIC Panel PC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSubrange\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePC677B\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Type\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePanel PC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePLM Product Phase\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eObsolete\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Type\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eTouch Display\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Size\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e15 inches\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDisplay Resolution\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1024 x 768\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProcessor Type\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIntel Celeron M440\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProcessor Speed\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1.86 GHz\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSLC\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 MB\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRAM Type\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDDR2 RAM\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRAM Capacity\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 GB\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBuffer SRAM\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 MB\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHard Drive Type\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSATA (2.5\")\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eHard Drive Capacity\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 x 250 GB\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRAID Configuration\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRAID1\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOptical Drive\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWithout optical drive\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEthernet Interfaces\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 x 10\/100\/1000 Mbit\/s\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUSB Interfaces\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4 x USB V2.0 (including front-side USB)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSerial Interface\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 x COM1\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExpansion Slots\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 x PCIe x4, 1 x PCI\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIndustrial Communication\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePROFIBUS\/MP\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply Input\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e110\/230 V AC\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply Unit\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWith NAMUR\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Cable\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEurope\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating System\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWindows XP Professional MUI\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSupported Languages\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDE, EN, FR, ES, IT, JA, ZH, KO\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e67.00 x 83.00 x 11.50 cm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eShipping Weight\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e17.00 kg\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommodity Code\u003c\/td\u003e\n                \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e85371098\u003c\/td\u003e\n            \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSafety First:\u003c\/strong\u003e Ensure all power to the installation area is de-energized and locked out before beginning any work.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the Panel PC into a suitable panel cutout, ensuring adequate clearance for ventilation and cable routing.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the 110\/230 V AC power supply cable to the unit. Verify correct voltage and grounding.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a proper protective earth (PE) connection to minimize electrical noise and ensure safety.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInterface Connections:\u003c\/strong\u003e Connect Ethernet cables to the 10\/100\/1000 Mbit\/s ports, USB devices to the USB V2.0 ports, and serial devices to the COM1 port as required by the application.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePROFIBUS\/MP Connection:\u003c\/strong\u003e If utilizing PROFIBUS\/MP, connect the appropriate cable, ensuring correct termination and shielding according to PROFIBUS guidelines.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Management:\u003c\/strong\u003e Route all cables to prevent strain, interference, and damage. Use cable ties and conduits where necessary.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations:\u003c\/strong\u003e Ensure the operating environment meets the specified temperature and humidity ranges for industrial PC equipment.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower On:\u003c\/strong\u003e After all connections are verified, re-energize the power supply and allow the system to boot.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52715879367019,"sku":"6AV7872-0BB22-0AC0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/6av7872-0bb22-0ac0-4xfrsczjhp3_5d3c8979-66b3-4c1b-a319-36e94c054701.jpg?v=1767073585","url":"https:\/\/www.plcprotech.com\/de\/products\/siemens-6av7872-0bb22-0ac0-simatic-panel-pc-677b","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}